Mechanisms of action behind the protective effects of proactive esophageal cooling during radiofrequency catheter ablation in the left atrium

被引:1
|
作者
Omotoye, Samuel [1 ]
Singleton, Matthew J. [2 ]
Zagrodzky, Jason [3 ]
Clark, Bradley [4 ]
Sharma, Dinesh [5 ]
Metzl, Mark D. [6 ]
Gallagher, Mark M. [7 ]
Meininghaus, Dirk Grosse [8 ]
Leung, Lisa [7 ]
Garg, Jalaj [9 ]
Warrier, Nikhil [10 ]
Panico, Ambrose [11 ]
Tamirisa, Kamala [12 ]
Sanchez, Javier [12 ]
Mickelsen, Steven [13 ]
Sardana, Mayank [14 ]
Shah, Dipak [15 ]
Athill, Charles [16 ]
Hayat, Jamal [17 ]
Silva, Rogelio [18 ,19 ]
Clark, Audra T. [20 ]
Gray, Maria [21 ]
Levi, Benjamin [20 ]
Kulstad, Erik [20 ]
Girouard, Steven [22 ]
Zagrodzky, Will [23 ]
Montoya, Marcela Mercado [24 ]
Bustamante, Tatiana Gomez [24 ]
Berjano, Enrique [25 ]
Gonzalez-Suarez, Ana [26 ,27 ]
Daniels, James [20 ]
机构
[1] Cleveland Clin, Cleveland, OH USA
[2] WellSpan York Hosp, York, PA USA
[3] Texas Cardiac Arrhythmia Inst, St Davids Med Ctr, Austin, TX USA
[4] Ascension St Vincent, Indianapolis, IN USA
[5] NCH Rooney Heart Inst, Naples, FL USA
[6] NorthShore Univ Hlth Syst, Evanston, IL USA
[7] St Georges Univ Hosp NHS Fdn Trust, London, England
[8] Carl Thiem Klinikum GmbH, Cottbus, Germany
[9] Loma Linda Univ, Med Ctr, Loma Linda, CA USA
[10] MemorialCare Heart & Vasc Inst, Fountain Valley, CA USA
[11] Cardiovasc Associates Mesa, Mesa, AZ USA
[12] Texas Cardiac Arrhythmia Inst, Cardiac Elect, Dallas, TX USA
[13] Scripps Hlth, La Jolla, CA USA
[14] Mayo Clin, Phoenix, AZ USA
[15] Ascens Providence Hosp, Detroit, MI USA
[16] Sharp Mem Hosp & Rehabil Ctr, San Diego, CA USA
[17] St Georges Univ Hosp, Dept Gastroenterol, London, England
[18] Univ Illinois, Div Gastroenterol, Dept Med, Chicago, IL USA
[19] Advocate Aurora Christ Med Ctr, Chicago, IL USA
[20] Univ Texas Southwestern Med Ctr, Dallas, TX USA
[21] Attune Med, Chicago, IL USA
[22] Ten15 Ventures, Westlake, OH USA
[23] Colorado Coll, Colorado Springs, CO USA
[24] In Silico Sci & Engn SAS, Medellin, Colombia
[25] Univ Politecn Valencia, Dept Elect Engn, Valencia, Spain
[26] Univ Galway, Sch Med, Translat Med Device Lab, Galway, Ireland
[27] Valencian Int Univ, Valencia, Spain
来源
HEART RHYTHM O2 | 2024年 / 5卷 / 06期
关键词
Atrial fibrillation; Radiofrequency ablation; Pulmonary vein isolation; Atrioesophageal fistula; Esophageal cooling; PREVENT THERMAL-INJURY; PULSED-FIELD ABLATION; PULMONARY VEIN ISOLATION; IRRIGATED INTRAESOPHAGEAL BALLOON; IRREVERSIBLE ELECTROPORATION IRE; SINGLE-INSTITUTION EXPERIENCE; BURN WOUND CONVERSION; TUMOR-NECROSIS-FACTOR; HEAT-TRANSFER DEVICE; TEMPERATURE MANAGEMENT;
D O I
10.1016/j.hroo.2024.05.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Proactive esophageal cooling for the purpose of reducing the likelihood of ablation-related esophageal injury resulting from radio frequency (RF) cardiac ablation procedures is increasingly being used and has been Food and Drug Administration cleared as a protective strategy during left atrial RF ablation for the treatment of atrial fibrillation. In this review, we examine the evidence supporting the use of proactive esophageal cooling and the potential mechanisms of action that reduce the likelihood of atrioesophageal fistula (AEF) formation. Although the pathophysiology behind AEF formation after thermal injury from RF ablation is not well studied, a robust literature on fistula formation in other conditions (eg, Crohn disease, cancer, and trauma) exists and the relationship to AEF formation is investigated in this review. Likewise, we examine the abundant data in the surgical literature on burn and thermal injury progression as well as the acute and chronic mitigating effects of cooling. We discuss the relationship of these data and maladaptive healing mechanisms to the well-recognized postablation pathophysiological effects after RF ablation. Finally, we review additional important considerations such as patient selection, clinical workflow, and implementation strategies for proactive esophageal cooling.
引用
收藏
页码:403 / 416
页数:14
相关论文
共 50 条
  • [31] The Biophysics of Passive Convective Cooling During Catheter Ablation with Gold versus Platinum Electrodes and Multielectrode Phased Radiofrequency Energy Delivery
    Haines, David E.
    Strunk, Aaron R.
    Novichenok, Alex
    Kirchhof, Nicole
    Stewart, Mark
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2015, 26 (11) : 1257 - 1261
  • [32] Relevance of imaging structures adjacent to the left atrium during catheter ablation for atrial fibrillation
    Donaldson, David M.
    Shah, Amar
    Heist, E. Kevin
    Barrett, Conor D.
    Holmvang, Godtfred
    Abbara, Suhny
    Ruskin, Jeremy
    Mansour, Moussa
    HEART RHYTHM, 2010, 7 (02) : 269 - 275
  • [33] Effect of Left Atrial Ablation Process and Strategy on Microemboli Formation During Irrigated Radiofrequency Catheter Ablation in an In Vivo Model
    Takami, Mitsuru
    Lehmann, H. Immo
    Parker, Kay D.
    Welker, Kirk M.
    Johnson, Susan B.
    Packer, Douglas L.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2016, 9 (01)
  • [34] Left Atrial-Esophageal Fistula Repair after Radiofrequency Catheter Ablation for Atrial Fibrillation
    Velotta, Jeffrey B.
    Vasquez, Charles R.
    Bolman, Ralph M.
    Dasilva, Marcelo C.
    THORACIC AND CARDIOVASCULAR SURGEON REPORTS, 2013, 2 (01) : 13 - 15
  • [35] Evaluation of the luminal esophageal temperature behavior during left atrium posterior wall ablation by means of second-generation cryoballoon
    Thiago Guimarães Osório
    Saverio Iacopino
    Hugo-Enrique Coutiño
    Erwin Ströker
    Juan Sieira
    Francesca Salghetti
    Varnavas Varnavas
    Muryo Terasawa
    Gaetano Paparella
    Lucio Capulzini
    Riccardo Maj
    Yves De Greef
    Pedro Brugada
    Carlo de Asmundis
    Gian-Battista Chierchia
    Journal of Interventional Cardiac Electrophysiology, 2019, 55 : 191 - 196
  • [36] Catheter tip cooling during radiofrequency ablation of intra-atrial reentry: Effects on power, temperature, and impedance
    Blaufox, AD
    Numan, MT
    Laohakunakorn, P
    Knick, B
    Paul, T
    Saul, JP
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2002, 13 (08) : 783 - 787
  • [37] Electrical and Thermal Effects of Esophageal Temperature Probes on Radiofrequency Catheter Ablation of Atrial Fibrillation: Results from a Computational Modeling Study
    Perez, Juan J.
    D'Avila, Andre
    Aryana, Arash
    Berjano, Enrique
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2015, 26 (05) : 556 - 564
  • [38] Esophageal Protection and Temperature Monitoring Using the Circa S-Cath™ Temperature Probe during Epicardial Radiofrequency Ablation of the Pulmonary Veins and Posterior Left Atrium
    Kronenberger, Rani
    Parise, Orlando
    Van Loo, Ines
    Gelsomino, Sandro
    Welch, Ashley
    De Asmundis, Carlo
    La Meir, Mark
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (23)
  • [39] Feasibility, safety, and efficacy of a novel preshaped nitinol esophageal deviator to successfully deflect the esophagus and ablate left atrium without esophageal temperature rise during atrial fibrillation ablation: The DEFLECT GUT study
    Parikh, Valay
    Swarup, Vijay
    Hantla, Jacob
    Vuddanda, Venkat
    Dar, Tawseef
    Yarlagadda, Bharath
    Di Biase, Luigi
    Al-Ahmad, Amin
    Natale, Andrea
    Lakkireddy, Dhanunjaya
    HEART RHYTHM, 2018, 15 (09) : 1321 - 1327
  • [40] Esophageal positions relative to the left atrium; data from 293 patients before catheter ablation of atrial fibrillation
    Starek, Zdenek
    Lehar, Frantisek
    Jez, Jiri
    Scurek, Martin
    Wolf, Jiri
    Kulik, Tomas
    Zbankova, Alena
    INDIAN HEART JOURNAL, 2018, 70 (01) : 37 - 44