Study on Vibration and Failure of Transverse Flow Turbine Based on Fluid-Structure Interaction

被引:1
作者
Song, Houbin [1 ]
Xie, Wenqi [1 ]
Han, Wei [1 ]
Wang, Shuai [2 ]
Huang, Xiaolong [2 ]
Qiu, Hongbo [3 ]
Li, Rennian [1 ]
机构
[1] Lanzhou Univ Technol, Coll Energy & Power Engn, Lanzhou, Gansu, Peoples R China
[2] Lanzhou Univ Technol, Coll Elect & Informat Engn, Lanzhou, Gansu, Peoples R China
[3] Zhengzhou Univ Light Ind, Elect & Informat Engn Inst, Zhengzhou, Henan, Peoples R China
基金
中国国家自然科学基金;
关键词
Fluid-structure interaction; tubular turbine; mode; vibration failure; KAPLAN TURBINE; VORTEX IDENTIFICATION; RUNNER CHAMBER; GENERATION; PREDICTION; MODEL;
D O I
10.1142/S0219455425502633
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
During the operation of a turbine, the water level drop can cause vibration and damage to the flow components, severely threatening its stability and reliability. Investigating the impact of operational parameters on the internal flow field and flow structures of tidal turbines under low flow conditions is crucial for peak shaving and deployment of tidal power stations. This paper takes a 24MW turbine as the research object, using numerical calculations to analyze the effects of tailwater height on the flow characteristics and structural properties of the unit under low flow conditions. It studies the hydraulic impact on the flow component walls under different operating parameters and verifies the reliability of numerical calculations through vibration and stress tests. The results show that the increase in tailwater level affects the turbine's flow characteristics, forming large-scale, high-intensity vortices in the internal flow field and causing pressure pulsations near the wall surface. Modal analysis reveals that under different tailwater heights, the maximum modal effective mass exists along the axis of the impeller, with modal frequencies higher than the main frequencies of pressure pulsations. The impeller region corresponds to the turbine chamber wall bearing significant stress, which induces strain. The magnitude of stress and the degree of strain are positively correlated with the tailwater height. The research findings provide guidance for tailwater regulation and stable operation of tidal power stations.
引用
收藏
页数:32
相关论文
共 72 条
[1]  
A. Inc, 2005, Ansys Coupled-Field Analysis Guide
[2]  
Ahmad M. S., 2020, Ind. J. Sci. Technol., V12, DOI [10.37934/cfdl.12.12.115136, DOI 10.37934/CFDL.12.12.115136]
[3]  
Amiri K., 2016, International Journal of Fluid Machinery and Systems, V9, P182
[4]   Dynamic response of a rub-impact rotor system under axial thrust [J].
An, Xueli ;
Zhou, Jianzhong ;
Xiang, Xiuqiao ;
Li, Chaoshun ;
Luo, Zhimeng .
ARCHIVE OF APPLIED MECHANICS, 2009, 79 (11) :1009-1018
[5]  
Andreas A., 2016, Continuum Damage and Fracture Mechanics
[6]   A new generation of small hydro and pumped-hydro power plants: Advances and future challenges [J].
Ardizzon, G. ;
Cavazzini, G. ;
Pavesi, G. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 31 :746-761
[7]   Sustainable and economical small-scale and low-head hydropower generation: A promising alternative potential solution for energy generation at local and regional scale [J].
Balkhair, Khaled S. ;
Rahman, Khalil Ur .
APPLIED ENERGY, 2017, 188 :378-391
[8]   The dynamic contact problem for a prestressed cylindrical tube filled with a fluid [J].
Belyankova, T. I. ;
Kalinchuk, V. V. .
PMM JOURNAL OF APPLIED MATHEMATICS AND MECHANICS, 2009, 73 (02) :209-219
[9]   Failure investigation of a Kaplan turbine blade lever [J].
Cao, Jingwei ;
Yang, Guangdong ;
Luo, Yongyao ;
Chen, Jie ;
Liao, Run ;
Wang, Zhengwei .
ENGINEERING FAILURE ANALYSIS, 2022, 142
[10]   Fatigue analysis in rotor of a prototype bulb turbine based on fluid-structure interaction [J].
Cao, Jingwei ;
Tian, Hong ;
Ahn, Soo-Hwang ;
Duo, Wenzhi ;
Bi, Huili ;
Zhao, Lin ;
Zhao, Guozheng ;
Gao, Haiyu ;
Wang, Mingming ;
Ma, Guoming ;
Wang, Zhengwei ;
Liu, Yan .
ENGINEERING FAILURE ANALYSIS, 2022, 132