Design and Verification of a New Fixture for Machining of Porous Blocks for Medical CAD/CAM Systems

被引:0
作者
Sokac, Mario [1 ]
Milosevic, Aleksandar [1 ]
Santosi, Zeljko [1 ]
Vukelic, Djordje [1 ]
Budak, Igor [1 ]
机构
[1] Univ Novi Sad, Fac Tech Sci, Trg Dositeja Obradovica 6, Novi Sad 21000, Serbia
来源
APPLIED SCIENCES-BASEL | 2025年 / 15卷 / 02期
关键词
fixture; design; porous block; CNC machining; FEM; MECHANICAL-PROPERTIES; BONE; FABRICATION; ACCURACY; OPTIMIZATION; SUPPORT; PARTS;
D O I
10.3390/app15020794
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This paper presents a new innovative approach for designing and manufacturing a fixture for locating and clamping porous blocks of biocompatible material, which is required for their machining on CNC machines. Manufacturing porous blocks for their application in medical and/or dental fields is gaining traction. However, limited solutions are available today. In order to address this issue, a new design has been proposed for locating and clamping porous blocks. Finite element analysis was used as a verification tool for the designed fixture with the workpiece, which showed a low concentration of stresses. After the manufacturing, dimensional verification in the form of CAD analysis showed small deviations on the manufactured object with deviations peaking around +0.015 mm, thus validating the adequate locating and clamping of the workpiece.
引用
收藏
页数:15
相关论文
共 51 条
  • [1] Vibrational characteristics of bone fracture and fracture repair: Application to excised rat femur
    Alizad, Azra
    Walch, Matthew
    Greenleaf, James F.
    Fatemi, Mostafa
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (03): : 300 - 308
  • [2] Machining of biocompatible materials - Recent advances
    Axinte, Dragos
    Guo, Yuebin
    Liao, Zhirong
    Shih, Albert J.
    MSaoubi, Rachid
    Sugita, Naohiko
    [J]. CIRP ANNALS-MANUFACTURING TECHNOLOGY, 2019, 68 (02) : 629 - 652
  • [3] Ayhan M., 2023, Med. Rec, V5, P342, DOI [10.37990/medr.1249118, DOI 10.37990/MEDR.1249118]
  • [4] Effects of material properties and hole designs of the jig on the fatigue life of dental implants
    Bae, Jong-Su
    Jeong, Hyun-Yong
    [J]. JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2012, 26 (03) : 759 - 766
  • [5] Influence of porosity on mechanical properties and in vivo response of Ti6Al4V implants
    Bandyopadhyay, Amit
    Espana, Felix
    Balla, Vamsi Krishna
    Bose, Susmita
    Ohgami, Yusuke
    Davies, Neal M.
    [J]. ACTA BIOMATERIALIA, 2010, 6 (04) : 1640 - 1648
  • [6] Application of Natrium Silicate as a Phase Change Material in Fixture Design
    Bijelic, Ivan
    Milovanovic, Vladimir
    Vukelic, Djordje
    Simunovic, Goran
    Prica, Miljana
    Sokac, Mario
    Tadic, Branko
    [J]. TEHNICKI VJESNIK-TECHNICAL GAZETTE, 2023, 30 (02): : 465 - 473
  • [7] Reconstruction of a Unilateral Alveolar Cleft Using a Customized Allogenic Bone Block and Subsequent Dental Implant Placement in an Adult Patient
    Blume, Oliver
    Back, Michael
    Born, Teresa
    Donkiewicz, Phil
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2019, 77 (10) : 2127.e1 - 2127.e11
  • [8] Bilateral maxillary augmentation using CAD/CAM manufactured allogenic bone blocks for restoration of congenitally missing teeth: A case report
    Blume, Oliver
    Donkiewicz, Phil
    Back, Michael
    Born, Teresa
    [J]. JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2019, 31 (03) : 171 - 178
  • [9] A review and analysis of current computer-aided fixture design approaches
    Boyle, Iain
    Rong, Yiming
    Brown, David C.
    [J]. ROBOTICS AND COMPUTER-INTEGRATED MANUFACTURING, 2011, 27 (01) : 1 - 12
  • [10] A biomechanical study of osseointegrated patient-matched additively manufactured implant for treatment of thumb amputees
    Bregoli, Chiara
    Stacchiotti, Federico
    Fiocchi, Jacopo
    Ferrari, Rubens
    Biffi, Carlo Alberto
    Morellato, Kavin
    Gruppioni, Emanuele
    Tuissi, Ausonio
    [J]. MEDICAL ENGINEERING & PHYSICS, 2023, 118