Wastewater treatment through a hybrid electrocoagulation and electro-Fenton process with a porous graphite air-diffusion cathode

被引:0
作者
Alismaeel, Ziad T. [1 ]
Saeed, Osama F. [1 ]
Abbar, Ali H. [1 ]
机构
[1] Univ Baghdad, Al Khwarizmi Coll Engn, Dept Biochem Engn, Baghdad, Iraq
关键词
Electrocoagulation; Electro-Fenton; Hospital wastewater; Chemical oxygen demand removal; Response surface methodology; Air diffusion cathode; ELECTROCHEMICAL OXIDATION; COD REMOVAL; OPTIMIZATION; DEGRADATION; DECOLORIZATION; PULP;
D O I
10.1016/j.cep.2025.110258
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Wastewater from hospitals is a major source of pollution, and its treatment to protect the environment is a challenge. Different traditional methods have been applied to treat hospital wastewater (HW). Recently, hybrid processes, such as electrocoagulation (EC) with the electro-Fenton (EF) process, have been found to outperform traditional methods in terms of their high removal rate, low sludge generation and energy consumption and environmental sustainability. Herein, a combined EF process integrated with EC was successfully applied to reduce the chemical O demand (COD) of HW. A batch tubular electrochemical reactor composed of a microporous graphite air diffusion cathode and a hollow cylinder Al anode was used as a new design to remove pollutants from HW. Response surface methodology was adopted to explore the effects of operating factors, which were represented by current density, Fe2+ concentration and time, on COD removal and identify their interactions. The best operating conditions were a current density of 20 mA/cm2, an Fe2+ concentration of 6 mM and a reaction time of 63 min. These conditions yielded a COD removal efficiency (RE %) of 93.5 % with an energy consumption of 18.325 kWh/kg COD. Time had the main effect on the RE % due to the synergistic effect of EC and EF. The hybrid system had higher efficiency and lower energy consumption and sludge production than individual EC or EF. Therefore, combining EC with EF could be a promising approach for the treatment of HW.
引用
收藏
页数:13
相关论文
共 91 条
[1]  
Abbas ZI, 2020, ENVIRON ENG MANAG J, V19, P2029
[2]  
Ahmad N., 2021, FRONT ENG BUILT ENV, V1, P1, DOI [10.1108/FEBE-02-2021-0002, DOI 10.1108/FEBE-02-2021-0002]
[3]   Synergistic effects of α-Fe2O3-TiO2 and Na2S2O8 on the performance of a non-thermal plasma reactor as a novel catalytic oxidation process for dimethyl phthalate degradation [J].
Ahmadi, Ehsan ;
Shokri, Babak ;
Mesdaghinia, Alireza ;
Nabizadeh, Ramin ;
Khani, Mohammad Reza ;
Yousefzadeh, Samira ;
Salehi, Mohammad ;
Yaghmaeian, Kamyar .
SEPARATION AND PURIFICATION TECHNOLOGY, 2020, 250
[4]   Electrocoagulation using aluminum electrodes as a sustainable and economic method for the removal of kinetic hydrate inhibitor (polyvinyl pyrrolidone) from produced wastewaters [J].
Al-Marri, Jawaher S. ;
Abouedwan, Aisha B. ;
Ahmad, Mohammad I. ;
Bensalah, Nasr .
FRONTIERS IN WATER, 2023, 5
[5]   The performance of pharmaceutical wastewater treatment system of electrocoagulation assisted adsorption using perforated electrodes to reduce passivation [J].
Al-Qodah, Zakaria ;
Al-Zghoul, Tharaa M. ;
Jamrah, Ahmad .
ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2024, 31 (13) :20434-20448
[6]  
Altin A, 2017, J ENVIRON PROT ECOL, V18, P652
[7]   A sustainable system for decontamination of cephalexin antibiotic using electrocoagulation technology and response surface methodology [J].
Arab, Maliheh ;
Danesh, Shahnaz .
REMEDIATION-THE JOURNAL OF ENVIRONMENTAL CLEANUP COSTS TECHNOLOGIES & TECHNIQUES, 2023, 33 (04) :365-378
[8]  
Arunachalam R., 2011, Optimized response surface methodology for adsorption of dyestuff from aqueous solution
[9]  
Asha G., 2016, J SCI RES REPORTS, V9, P1, DOI [10.9734/JSRR/2016/22815, DOI 10.9734/JSRR/2016/22815]
[10]   Fenton's peroxidation and coagulation processes for the treatment of combined industrial and domestic wastewater [J].
Badawy, M. I. ;
Ali, M. E. M. .