Optimizing economic performances of foundation earth-to-air heat exchangers for low-technology residential air-conditioning

被引:1
作者
Patin, Mathieu [1 ,2 ]
Rousse, Daniel R. [2 ]
机构
[1] Univ Franche Comte, UTBM, CNRS, FEMTO ST, Belfort, France
[2] Univ Quebec, Ecole Technol Super, Grp t3e, Montreal, PQ, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Geothermic; Earth-to-air heat exchanger; Domestic load modeling; TRNSYS; Low technology; Environmental; INTEGRATION; SIMULATION; SYSTEMS; CLIMATE;
D O I
10.1016/j.enbuild.2024.115250
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Despite its classification as a low-technology and nearly passive sustainable system, the use of earth-to-air heat exchangers in residential settings remains relatively uncommon, primarily due to the expenses associated with excavation. Nevertheless, positioning the heat exchanger around the building's foundations during construction offers a potential solution to mitigate these costs. This study conducts an economic viability analysis for such a configuration, focusing on a typical single-family dwelling in Montre<acute accent>al, Canada. A sizing investigation revealed that ducts with relatively small diameters (approximately 20 cm), constructed from cost-effective materials, are optimal. These ducts should be placed as deep and as distant from the foundation as feasible. The optimal heat exchanger configuration reduces the building's heating/cooling load by 701 kWh per year (4.3 %). However, despite minimal excavation expenses, the economic analysis suggests an unviable Levelized cost of Energy for the province of Quebec (0.182 US$.kWh- 1) compared to the low electricity rates in the area (a domestic fare of 0.059 US$.kWh- 1). The findings underscore notable losses attributable to thermal short-circuiting influenced by the basement walls and coupling affected by the mandatory Heat Recovery Ventilation system. Overall, it was determined that only 60 % of the sensible heat exchanged with the soil effectively contributes to load reduction.
引用
收藏
页数:14
相关论文
共 47 条
  • [31] Validation of CFD model for simulation of multi-pipe earth-to-air heat exchangers (EAHEs) flow performance
    Amanowicz, Lukasz
    Wojtkowiak, Janusz
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2018, 5 : 44 - 49
  • [32] Air-conditioning anthropogenic heat in high-density residential areas: Spatial patterns and impacts
    Zhou, Xue
    Wang, Junqi
    Zhang, Ruijun
    Chen, Gang
    Cao, Shi-Jie
    ENERGY AND BUILDINGS, 2024, 318
  • [33] A life cycle analysis techno-economic assessment framework for evaluating future technology pathways ? The residential air-conditioning example
    Li, Yanjie
    Nian, Victor
    Li, Hailong
    Liu, Shengchun
    Wang, Yabo
    APPLIED ENERGY, 2021, 291
  • [34] Experimental investigation and CFD simulation of multi-pipe earth-to-air heat exchangers (EAHEs) flow performance
    Amanowicz, Lukasz
    Wojtkowiak, Janusz
    INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY SYSTEMS AND ENVIRONMENTAL ENGINEERING (ASEE17), 2017, 22
  • [35] Techno-Economic Feasibility Study of Earth Air Heat Exchangers for Gas Turbine Inlet Air Cooling
    Bahmani, Mohammad Hossein
    Hakkaki-Fard, Ali
    HEAT TRANSFER ENGINEERING, 2024,
  • [36] Evaluating cooling and thermal performances of a double pipe rectangular Earth-to-Air Heat Exchanger provided with a convection zone
    Benhammou, M.
    Boubekeur, L.
    Youcef, A.
    Korti, M. C.
    JOURNAL OF ENERGY STORAGE, 2023, 72
  • [37] An all-in-one machine coupled with a horizontal ground heat exchanger for the air-conditioning of a residential building
    Bordignon, Sara
    Carnieletto, Laura
    Zarrella, Angelo
    BUILDING AND ENVIRONMENT, 2022, 207
  • [38] Optimizing the thermal environment of greenhouse with multi-pipe earth-to-air heat exchanger system using the Taguchi method
    Qi, Di
    Liu, Qian
    Zhao, Chuangyao
    Li, Shixiong
    Song, Bingye
    Li, Angui
    APPLIED THERMAL ENGINEERING, 2024, 242
  • [39] Validating Models for Calculating the Efficiency of Earth-to-Air Heat Exchangers Based on Laboratory Data for Fall and Winter 2016 in Northeastern Poland
    Skotnicka-Siepsiak, Aldona
    Wesolowski, Maciej
    Piechocki, Janusz
    POLISH JOURNAL OF ENVIRONMENTAL STUDIES, 2019, 28 (05): : 3431 - 3437
  • [40] Validation of modified one-dimensional models simulating the thermal behavior of earth-to-air heat exchangers-Comparative analysis of modelling and experimental results
    Papakostas, K. T.
    Tsamitros, A.
    Martinopoulos, G.
    GEOTHERMICS, 2019, 82 : 1 - 6