Assessment of Seismic Capacity of Building Envelope Nonstructural Components

被引:0
作者
Bonati, Antonio [1 ]
Caterino, Nicola [2 ,3 ]
Cimmino, Maddalena [3 ]
Coppola, Orsola [1 ]
De Angelis, Alessandra [4 ]
Maddaloni, Giuseppe [3 ,4 ]
Occhiuzzi, Antonio [1 ,2 ]
机构
[1] CNR, Construct Technol Inst, Milan, Italy
[2] Univ Naples Parthenope, Dept Engn, Naples, Italy
[3] CNR, Construct Technol Inst, Naples, Italy
[4] Univ Sannio, Dept Engn, Benevento, Italy
关键词
Non-structural components; external wall claddings; precast concrete panel; connections; seismic assessment methods; dynamic tests; quasi-static tests; RESPONSE SPECTRA; DESIGN METHODS; PERFORMANCE;
D O I
10.1080/13632469.2025.2470328
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper describes an innovative "testing set" for assessing the seismic capacity of building envelopes consisting of a specialized testing equipment and a companion testing protocol. The equipment has been designed for assessing the seismic capacity of either building envelopes or their components, based on a historical review of testing machine for such nonstructural elements. The testing protocol is designed to adapt recent code provisions to building envelopes. The testing set is proposed for both external cladding systems and precast concrete panels' connections. In the latter case, the experimental activity led to an assessment criterium for the connections seismic design.
引用
收藏
页数:36
相关论文
共 38 条
  • [1] Recommended Dynamic Test Method for Determining the Seismic Drift Causing Glass Fallout from Window Wall, Curtain Wall and Storefront Systems, (2001)
  • [2] Aghababaei M., Okamoto C., Koliou M., Nagae T., Pantelides C.P., Ryan K.L., Barbosa A.R., Pei S., van de Lindt J.W., Dashti S., Full-Scale Shake Table Test Damage Data Collection Using Terrestrial Laser-Scanning Techniques, Journal of Structural Engineering–ASCE, 147, 3, (2021)
  • [3] Bedon C., Xihong A., Santos F., Honfi D., Kozloski M., Arrioni M., Figuli L., Lange D., Performance of Structural Glass façades Under Extreme Loads–Design Methods, Existing Research, Current Issues and Trends, Construction and Building Materials, 163, 2018, pp. 921-937, (2018)
  • [4] Behr R.A., Belarbi A., Brown A.T., Seismic Performance of Architectural Glass in a Storefront Wall System, Earthquake Spectra, 11, 3, pp. 367-391, (1995)
  • [5] Behr R., Belarbi A., Seismic Test Methods for Architectural Glass Systems, Earthquake Spectra, 12, 1, pp. 129-143, (1996)
  • [6] Bianchi S., Andriotis C., Klein T., Overend M., Multi-Criteria Design Methods in façade Engineering: State-Of-The-Art and Future Trends, Building & Environment, 250, 2024, (2024)
  • [7] Bianchi S., Pampanin S., Fragility Functions for Architectural Nonstructural Components, ASCE Journal of Structural Engineering, 148, 10, (2022)
  • [8] Bouwkamp J., Behavior of Window Panels Under In-Plane Forces, UCB/SESM Report 1960/06, (1960)
  • [9] Bouwkamp J., Meehan J., Drift Limitations Imposed by Glass, Proc. of the Second World Conference on Earthquake Engineering (2WCEE), (1960)
  • [10] Brueggeman J.L., Behr R.A., Wulfert H., Memari A.M., Kremer P.A., Dynamic Racking Performance of an Earthquake-Isolated Curtain Wall System, Earthquake Spectra, 16, 4, pp. 735-756, (2000)