Detection of cortisol using long range surface plasmon resonance sensor with enhance figure of merit

被引:6
作者
Kumar, Rajeev [1 ]
Pandey, Vimal Kant [2 ]
Alam, Javed [3 ]
Garia, Suman [4 ]
Singh, Shivam [5 ]
机构
[1] Graph Era Deemed Univ, Dept Elect & Commun Engn, Dehra Dun 248002, Uttaranchal, India
[2] MOXA Inc, Reliabil Mgmt Dept, Failure Anal Engn Sect, Taipei, Taiwan
[3] Chandigarh Univ, Univ Inst Comp, Chandigarh, Punjab, India
[4] Govt PG Coll Dwarahat, Dept Phys, Almora 263653, Uttaranchal, India
[5] ABES Engn Coll, Dept Elect & Commun Engn, Ghaziabad, Uttar Pradesh, India
关键词
Detection accuracy; Figure of merit; Penetration depth; Long range surface plasmon polaritons; MXENE;
D O I
10.1016/j.microc.2025.112696
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Long-range surface plasmon resonance (LRSPR) sensors have been designed using franckeite 2D material for the detection of cortisol. There is growing interest in the complex sulfide mineral franckeite because of its possible application in raising the detection accuracy (DA) and figure of merit (FoM) of LRSPR sensors. Hence, franckeite layer is used for attaching the biomolecules of cortisol with concentration. At minimum reflectance, the maximum FoM of 4046.42/RIU and 7831.79/RIU is attained with cortisol concentrations of 0.36 ng/mL and 4.5 ng/mL, respectively. The maximum FoM of 9126/RIU and 11903/RIU is achieved at 1200 nm and 11 nm thickness of Teflon and silver (Ag) layer, respectively using franckeite layer, with cortisol concentration of 0.36 ng/ml and 4.5 ng/ml. At same thickness and cortisol concentration, the DA of 333.33/degrees and 434.78/degrees is obtained. Moreover, the penetration depth (PD) of 3095.02 nm is achieved at 0.36 ng/mL concentration of cortisol. Franckeite high refractive index (RI) enhances the plasmonic coupling, making the SPR signal more noticeable. This can improve the sensor's DA and FoM by enhancing its ability to detect minute variations in the RI.
引用
收藏
页数:8
相关论文
共 50 条
[41]   A Numerical Analysis for the Detection of Water Salinity Concentration Using Long-Range Surface Plasmon Resonance Biosensor With TMDCs-Teflon/Cytop [J].
Kumar, Rajeev ;
Singh, Shivam ;
Garia, Lalit ;
Chaudhary, Bhargavi ;
Singh, Maneesh Kumar ;
Kumar, Santosh .
IEEE TRANSACTIONS ON PLASMA SCIENCE, 2024, 52 (08) :3136-3144
[42]   A Wedge-Shaped Au Thin Film: Integrating Multiple Surface Plasmon Resonance Sensors in a Single Chip and Enhancing the Figure of Merit [J].
Shimizu, Hiromasa ;
Ogura, Takahiro ;
Maeda, Takumi ;
Suzuki, Shogo .
FRONTIERS IN NANOTECHNOLOGY, 2021, 3
[43]   Enhanced Figure of Merit in Fano Resonance-Based Plasmonic Refractive Index Sensor [J].
Zafar, Rukhsar ;
Salim, Mohammad .
IEEE SENSORS JOURNAL, 2015, 15 (11) :6313-6317
[44]   Composite layer based plasmon waveguide resonance for label-free biosensing with high figure of merit [J].
Zhang, Pengfei ;
Liu, Le ;
He, Yonghong ;
Chen, Xiaoxia ;
Ma, Kaijie ;
Wei, Dong ;
Wang, Hui ;
Shao, Qi .
SENSORS AND ACTUATORS B-CHEMICAL, 2018, 272 :69-78
[45]   Ultra-sensitive early detection of colorectal cancer using surface plasmon resonance sensor: theoretical analysis [J].
Karki, Bhishma ;
Pal, Amrindra ;
Dhiman, Gaurav ;
Ahmed, Mohammad Z. .
MICROCHIMICA ACTA, 2025, 192 (02)
[46]   Surface Plasmon Resonance Sensor Using Graphene/MXene Heterostructure for Detection of Salinity-Induced Water Contamination [J].
Paswan, Mohan Kumar ;
Basu, Rikmantra .
PLASMONICS, 2025,
[47]   Enhanced refractive index sensing using a surface plasmon resonance sensor with heterostructure [J].
Kumar, Rajeev ;
Agarwal, Sajal ;
Pal, Sarika ;
Prajapati, Yogendra Kumar ;
Saini, J. P. .
MICRO AND NANOSTRUCTURES, 2023, 183
[48]   Sensitivity Enhancement of Silicon Layer-Based Surface Plasmon Resonance Sensor for Detection of Escherichia coli Bacteria [J].
Vadivu, N. Shanmuga ;
Mageswari, M. ;
Suma, N. ;
Lavadiya, Sunil .
PLASMONICS, 2025, 20 (01) :407-419
[49]   Enhanced detection accuracy and signal-to-noise ratio of surface plasmon resonance based refractive index sensor with the addition of thicker layer of Silicon [J].
Kushwah, Himanshu ;
Anand, Jagneet Kaur .
OPTICAL MATERIALS, 2023, 140
[50]   Sensitivity Improvement of Surface Plasmon Resonance Sensor for Glucose Detection in Urine Samples Using Heterogeneous Layers: An Analytical Perspective [J].
Karki, Bhishma ;
Uniyal, Arun ;
Sarkar, Partha ;
Pal, Amrindra ;
Yadav, Ram Bharos .
JOURNAL OF OPTICS-INDIA, 2024, 53 (03) :2567-2577