Personalizing the Use of a Intermittently Scanned Continuous Glucose Monitoring Device in Individuals With Type 1 Diabetes: A Cost-Effectiveness Perspective in the Netherlands (FLARE-NL 9)

被引:5
|
作者
Emamipour, Sajad [1 ]
van Dijk, Peter R. [2 ]
Bilo, Henk J. G. [3 ,4 ]
Edens, Mireille A. [5 ]
van der Galien, Onno [6 ]
Postma, Maarten J. [7 ,8 ]
Feenstra, Talitha L. [9 ,10 ]
van Boven, Job F. M. [1 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Clin Pharm & Pharmacol, Hanzepl 1, NL-9700 RB Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Dept Endocrinol, Groningen, Netherlands
[3] Isala, Diabet Ctr, Zwolle, Netherlands
[4] Univ Groningen, Univ Med Ctr Groningen, Dept Internal Med, Groningen, Netherlands
[5] Isala, Dept Innovat & Sci, Zwolle, Netherlands
[6] Achmea, Zeist, Netherlands
[7] Univ Groningen, Univ Med Ctr Groningen, Dept Hlth Sci, Groningen, Netherlands
[8] Univ Groningen, Fac Econ & Business, Dept Econ Econometr & Finance, Groningen, Netherlands
[9] Univ Groningen, Groningen Res Inst Pharm, Fac Sci & Engn, Groningen, Netherlands
[10] Natl Inst Publ Hlth & Environm RIVM, Bilthoven, Netherlands
来源
JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY | 2024年 / 18卷 / 01期
关键词
cost-effectiveness analysis; hypoglycemia; intermittently scanned continuous glucose monitoring; type 1 diabetes mellitus;
D O I
10.1177/19322968221109841
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: Intermittently scanned continuous glucose monitoring (isCGM) is a method to monitor glucose concentrations without using a finger prick. Among persons with type 1 diabetes (T1D), isCGM results in improved glycemic control, less disease burden and improved health-related quality of life (HRQoL). However, it is not clear for which subgroups of patients isCGM is cost-effective. We aimed to provide a real-world cost-effectiveness perspective. Methods: We used clinical data from a 1-year nationwide Dutch prospective observational study (N = 381) and linked these to insurance records. Health-related quality of life was assessed with the EQ-5D-3L questionnaire. Individuals were categorized into 4 subgroups: (1) frequent hypoglycemic events (58%), (2) HbA1c > 70 mmol/mol (8.5%) (19%), (3) occupation that requires avoiding finger pricks and/or hypoglycemia (5%), and (4) multiple indications (18%). Comparing costs and outcomes 12 months before and after isCGM initiation, incremental cost-effectiveness ratios (ICERs) were calculated for the total cohort and each subgroup from a societal perspective (including healthcare and productivity loss costs) at the willingness to pay of <euro>50,000 per quality-adjusted life year (QALY) gained. Results: From a societal perspective, isCGM was dominant in all subgroups (ie higher HRQoL gain with lower costs) except for subgroup 1. From a healthcare payer perspective, the probabilities of isCGM being cost-effective were 16%, 9%, 30%, 98%, and 65% for the total cohort and subgroup 1, 2, 3, and 4, respectively. Most sensitivity analyses confirmed these findings. Conclusions: Comparing subgroups of isCGM users allows to prioritize them based on cost-effectiveness. The most cost-effective subgroup was occupation-related indications, followed by multiple indications, high HbA1c and the frequent hypoglycemic events subgroups. However, controlled studies with larger sample size are needed to draw definitive conclusions.
引用
收藏
页码:135 / 142
页数:8
相关论文
共 35 条
  • [1] Estimating the cost-effectiveness of intermittently scanned continuous glucose monitoring in adults with type 1 diabetes in England
    Elliott, Rachel A.
    Rogers, Gabriel
    Evans, Mark L.
    Neupane, Sankalpa
    Rayman, Gerry
    Lumley, Sarah
    Cranston, Iain
    Narendran, Parth
    Sutton, Christopher J.
    Taxiarchi, Vicky P.
    Burns, Matthew
    Thabit, Hood
    Wilmot, Emma G.
    Leelarathna, Lalantha
    DIABETIC MEDICINE, 2024, 41 (03)
  • [2] Population-Level Impact and Cost-effectiveness of Continuous Glucose Monitoring and Intermittently Scanned Continuous Glucose Monitoring Technologies for Adults With Type 1 Diabetes in Canada: A Modeling Study
    Rotondi, Michael A.
    Wong, Octavia
    Riddell, Michael
    Perkins, Bruce
    DIABETES CARE, 2022, 45 (09) : 2012 - 2019
  • [3] Cost-Effectiveness of Hybrid Closed Loop Insulin Pumps Versus Multiple Daily Injections Plus Intermittently Scanned Glucose Monitoring in People With Type 1 Diabetes in The Netherlands
    Serne, Erik H.
    Roze, Stephane
    Buompensiere, Maria, I
    Valentine, William J.
    De Portu, Simona
    de Valk, Harold W.
    ADVANCES IN THERAPY, 2022, 39 (04) : 1844 - 1856
  • [4] Cost-Effectiveness of Intermittently Scanned Continuous Glucose Monitoring Versus Advanced Hybrid Closed-Loop Systems in Type 1 Diabetes: Comment on Jendle et al.
    Levrat-Guillen, Fleur
    Ghazi, Tara
    DIABETES THERAPY, 2022, 13 (05) : 1121 - 1123
  • [5] Cost-effectiveness of continuous glucose monitoring and intensive insulin therapy for type 1 diabetes
    McQueen R.B.
    Ellis S.L.
    Campbell J.D.
    Nair K.V.
    Sullivan P.W.
    Cost Effectiveness and Resource Allocation, 9 (1)
  • [6] Efficacy of unblinded and blinded intermittently scanned continuous glucose monitoring for glycemic control in adults with type 1 diabetes
    Guo, Lixin
    Li, Yuxiu
    Zhang, Mei
    Xiao, Xinhua
    Kuang, Hongyu
    Yang, Tao
    Jia, Xiaofan
    Zhang, Xianbo
    FRONTIERS IN ENDOCRINOLOGY, 2023, 14
  • [7] A systematic review: Cost-effectiveness of continuous glucose monitoring compared to self-monitoring of blood glucose in type 1 diabetes
    Jiao, Yuxin
    Lin, Rose
    Hua, Xinyang
    Churilov, Leonid
    Gaca, Michele J.
    James, Steven
    Clarke, Philip M.
    O'Neal, David
    Ekinci, Elif, I
    ENDOCRINOLOGY DIABETES & METABOLISM, 2022, 5 (06)
  • [8] Impact of intermittently scanned continuous glucose monitoring with alarms on sleep and metabolic outcomes in children and adolescents with type 1 diabetes
    Franceschi, Roberto
    Scotton, Chiara
    Leonardi, Letizia
    Cauvin, Vittoria
    Maines, Evelina
    Angriman, Marco
    Pertile, Riccardo
    Valent, Francesca
    Soffiati, Massimo
    Faraguna, Ugo
    ACTA DIABETOLOGICA, 2022, 59 (07) : 911 - 919
  • [9] Comparison of Glycemic Metrics Measured Simultaneously by Intermittently Scanned Continuous Glucose Monitoring and Real-Time Continuous Glucose Monitoring in Pregnant Women with Type 1 Diabetes
    Norgaard, Sidse Kjaerhus
    Mathiesen, Elisabeth Reinhardt
    Norgaard, Kirsten
    Ringholm, Lene
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 (10) : 665 - 672
  • [10] Long-Term Cost-Effectiveness of Continuous Glucose Monitoring Versus Self-Monitoring of Blood Glucose in Adults With Type 1 Diabetes in Iran
    Molaee, Mohsen Choband
    Naseri, Zahra Gharib
    Karami, Masoud Ali