Preliminary Design of Water Intake System for In-situ Water Quality Assessment

被引:0
作者
Robi, Fatin Izyani Mohamad [1 ]
Abd Rahman, Mohamad Faizal [1 ]
Rohaizan, Azka [1 ]
Baharuddin, Rohaiza [1 ]
Abdullah, Mohd Hanapiah [1 ]
机构
[1] Univ Teknol MARA, Cawangan Pulau Pinang, Elect Engn Studies, Coll Engn, George Town, Malaysia
来源
2024 IEEE 14TH SYMPOSIUM ON COMPUTER APPLICATIONS & INDUSTRIAL ELECTRONICS, ISCAIE 2024 | 2024年
关键词
intake system; peristaltic pump; water quality; flow rate; in-situ;
D O I
10.1109/ISCAIE61308.2024.10576544
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Water quality at specific places is normally assessed by collecting water samples at site and transporting them to the laboratory for testing purposes. For in situ measurement, a popular method of collecting the samples is by using a conventional sample test kit such as syringe and cuvette. This approach, however, requires human intervention and needs to be done manually. The need for a mechanism to improve the sampling technique is crucial for in situ measurement such as for microfluidic and point-of-care devices. The aim of this work is to propose an intake system with the capability of controlling the samples that flow into the testing system. The circuit is designed and simulated using TinkerCAD software to observe and analyze the electrical characteristics of the proposed system in which a peristaltic pump is used as the main component in the intake system. Based on simulation work, 100 Omega rheostat setting between 10 to 50% was found to be suitable to drive a 12 V motor (representing a peristaltic pump) and satisfy the minimum operating current of 106.5 mA. The intake system was successfully developed to be capable of controlling the flow rate of intake samples through rheostat setting. At this range of rheostat setting, voltage characteristics for simulated and actual setup show similar patterns with less than 7% deviation. Through experiment, the system produced a range of flow rates between 0.842 ml(3)/s to 1.7549 ml(3)/s at controlling voltage from 6.2073 V to 10.5731 V. The relationship between the controlling voltage and flow intake was determined as a preliminary effort to develop a voltage-controlled intake system for multipurpose in situ application. Further improvement can be made by translating this voltage into its respective flow rate for display purposes and by integrating a commercial flow sensor for verification. This preliminary work could contribute to the future development of an intake system that is capable of performing a continuous and segmented automatic sampling to improve the traditional way of sampling process, which is manually done.
引用
收藏
页码:478 / 481
页数:4
相关论文
共 50 条
[41]   Drinking water quality and health risk assessment of intake and point-of-use water sources in Tano North Municipality, Ghana [J].
Yeboah, Saeed Ibn Idris K. ;
Antwi-Agyei, Prince ;
Domfeh, Martin Kyereh .
JOURNAL OF WATER SANITATION AND HYGIENE FOR DEVELOPMENT, 2022, 12 (02) :157-167
[42]   Machine learning-based water quality prediction using octennial in-situ Daphnia magna biological early warning system data [J].
Jeong, Heewon ;
Park, Sanghyun ;
Choi, Byeongwook ;
Yu, Chung Seok ;
Hong, Ji Young ;
Jeong, Tae-Yong ;
Cho, Kyung Hwa .
JOURNAL OF HAZARDOUS MATERIALS, 2024, 465
[43]   IN SITU WATER QUALITY DATA FOR THE CHESAPEAKE BAY [J].
Memarsadeghi, Nargess ;
Uz, Stephanie Schollaert ;
McKay, John R. ;
Santana, Barbara .
2022 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS 2022), 2022, :6876-6879
[44]   Performance indicators model assessment for water system quality and supply in Montenegro [J].
Doklestic, Olivera ;
Miloradov, Mirjana Vojinovic ;
Elezovic, Natasa ;
Kolakovic, Srdan ;
Simeunovic, Nenad .
JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2024, 89 (05) :705-714
[45]   A low-cost tide measurement system for water quality assessment [J].
Pereira, J. M. Dias ;
Postolache, O. ;
Girao, P. Silva .
2006 IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE PROCEEDINGS, VOLS 1-5, 2006, :2226-+
[46]   Decision Support System for Temporal Trend Assessment of Water Quality Data [J].
Tennakoon, Sunil ;
Robinson, David ;
Shen, Shuangyang .
18TH WORLD IMACS CONGRESS AND MODSIM09 INTERNATIONAL CONGRESS ON MODELLING AND SIMULATION: INTERFACING MODELLING AND SIMULATION WITH MATHEMATICAL AND COMPUTATIONAL SCIENCES, 2009, :2443-2449
[47]   Isopleth mapping and in-situ fluoride dependence on water quality in the Krishnagiri block of Tamil Nadu in South India [J].
Karthikeyan, G ;
Shunmugasundarraj, A .
FLUORIDE, 2000, 33 (03) :121-127
[48]   International standardization of water analysisBasis for comparative assessment of water quality [J].
Sibylle Schmidt .
Environmental Science and Pollution Research, 2003, 10 :183-187
[49]   Assessment of Drinking Water Quality from Bottled Water Coolers [J].
Farhadkhani, Marzieh ;
Nikaeen, Mahnaz ;
Akbari Adergani, Behrouz ;
Hatamzadeh, Maryam ;
Nabavi, Bibi Fatemeh ;
Hassanzadeh, Akbar .
IRANIAN JOURNAL OF PUBLIC HEALTH, 2014, 43 (05) :674-681
[50]   Water supply in cities of Belarus: Water quality and risk assessment [J].
Kukharchyk, Tamara ;
Khomich, Valery .
INTEGRATED URBAN WATER RESOURCES MANAGEMENT, 2006, :131-+