Preliminary Design of Water Intake System for In-situ Water Quality Assessment

被引:0
作者
Robi, Fatin Izyani Mohamad [1 ]
Abd Rahman, Mohamad Faizal [1 ]
Rohaizan, Azka [1 ]
Baharuddin, Rohaiza [1 ]
Abdullah, Mohd Hanapiah [1 ]
机构
[1] Univ Teknol MARA, Cawangan Pulau Pinang, Elect Engn Studies, Coll Engn, George Town, Malaysia
来源
2024 IEEE 14TH SYMPOSIUM ON COMPUTER APPLICATIONS & INDUSTRIAL ELECTRONICS, ISCAIE 2024 | 2024年
关键词
intake system; peristaltic pump; water quality; flow rate; in-situ;
D O I
10.1109/ISCAIE61308.2024.10576544
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Water quality at specific places is normally assessed by collecting water samples at site and transporting them to the laboratory for testing purposes. For in situ measurement, a popular method of collecting the samples is by using a conventional sample test kit such as syringe and cuvette. This approach, however, requires human intervention and needs to be done manually. The need for a mechanism to improve the sampling technique is crucial for in situ measurement such as for microfluidic and point-of-care devices. The aim of this work is to propose an intake system with the capability of controlling the samples that flow into the testing system. The circuit is designed and simulated using TinkerCAD software to observe and analyze the electrical characteristics of the proposed system in which a peristaltic pump is used as the main component in the intake system. Based on simulation work, 100 Omega rheostat setting between 10 to 50% was found to be suitable to drive a 12 V motor (representing a peristaltic pump) and satisfy the minimum operating current of 106.5 mA. The intake system was successfully developed to be capable of controlling the flow rate of intake samples through rheostat setting. At this range of rheostat setting, voltage characteristics for simulated and actual setup show similar patterns with less than 7% deviation. Through experiment, the system produced a range of flow rates between 0.842 ml(3)/s to 1.7549 ml(3)/s at controlling voltage from 6.2073 V to 10.5731 V. The relationship between the controlling voltage and flow intake was determined as a preliminary effort to develop a voltage-controlled intake system for multipurpose in situ application. Further improvement can be made by translating this voltage into its respective flow rate for display purposes and by integrating a commercial flow sensor for verification. This preliminary work could contribute to the future development of an intake system that is capable of performing a continuous and segmented automatic sampling to improve the traditional way of sampling process, which is manually done.
引用
收藏
页码:478 / 481
页数:4
相关论文
共 50 条
[31]   The Geographical Information System (GIS) based water quality assessment of a drinking water distribution system in the Denizli City [J].
Koc, Abdullah Cem ;
Ciner, Fehiman ;
Toprak, Selcuk ;
Selcuk, Huseyin ;
Aktan, Burcu .
DESALINATION AND WATER TREATMENT, 2010, 19 (1-3) :318-324
[32]   Assessment of Falaj Water Quality [J].
Shaik, Feroz ;
AL-Siyabi, Said S. ;
Lakkimsetty, Nageswara Rao ;
Syed, Murtuza Ali ;
Mohammed, Nayeemuddin .
ASIAN JOURNAL OF WATER ENVIRONMENT AND POLLUTION, 2021, 18 (01) :25-30
[33]   Design and Implementation of Cost Effective Water Quality Evaluation System [J].
Faruq, Md. Omar ;
Emu, Injamamul Hoque ;
Haque, Md. Nazmul ;
Dey, Maitry ;
Das, N. K. ;
Dey, Mrinmoy .
2017 IEEE REGION 10 HUMANITARIAN TECHNOLOGY CONFERENCE (R10-HTC), 2017, :860-863
[34]   WATER QUALITY ASSESSMENT AFTER MODERNIZATION OF THE TECHNOLOGICAL SYSTEM IN THE WATER TREATMENT PLANT IN DRZENIN (POLAND) [J].
Jakubaszek, Anita .
CIVIL AND ENVIRONMENTAL ENGINEERING REPORTS, 2019, 29 (04) :257-266
[35]   Design of Remote Water Quality Monitoring System Based on GPRS [J].
Jin, Yi ;
Zhang, Mu ;
Gu, Dagang .
ENVIRONMENT MATERIALS AND ENVIRONMENT MANAGEMENT PTS 1-3, 2010, 113-116 :1411-1414
[36]   Water pollution and the assessment of water quality parameters: a review [J].
Misman, Nurafifa Akmal ;
Sharif, Mohd Faez ;
Chowdhury, Ahmed Jalal Khan ;
Azizan, Nur Hafizah .
DESALINATION AND WATER TREATMENT, 2023, 294 :79-88
[37]   Water Quality Management in a Water Distribution System [J].
Kowalski, Dariusz .
OCHRONA SRODOWISKA, 2009, 31 (03) :37-40
[38]   Passive sampling of perfluorinated chemicals in water: In-situ calibration [J].
Kaserzon, Sarit L. ;
Hawker, Darryl W. ;
Booij, Kees ;
O'Brien, Dominique S. ;
Kennedy, Karen ;
Vermeirssen, Etienne L. M. ;
Mueller, Jochen F. .
ENVIRONMENTAL POLLUTION, 2014, 186 :98-103
[39]   A FLUORESCENCE LIDAR SIMULATOR FOR THE DESIGN OF ADVANCED WATER QUALITY ASSESSMENT METHODOLOGIES [J].
Matteoli, Stefania ;
Diani, Marco ;
Corsini, Giovanni .
IGARSS 2020 - 2020 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, 2020, :3743-3746
[40]   Assessment of Cau River water quality assessment using a combination of water quality and pollution indices [J].
Son, Cao Truong ;
Giang, Nguyen Thi Huong ;
Thao, Trieu Phuong ;
Nui, Nguyen Hai ;
Lam, Nguyen Thanh ;
Cong, Vo Huu .
JOURNAL OF WATER SUPPLY RESEARCH AND TECHNOLOGY-AQUA, 2020, 69 (02) :160-172