Preliminary Design of Water Intake System for In-situ Water Quality Assessment

被引:0
作者
Robi, Fatin Izyani Mohamad [1 ]
Abd Rahman, Mohamad Faizal [1 ]
Rohaizan, Azka [1 ]
Baharuddin, Rohaiza [1 ]
Abdullah, Mohd Hanapiah [1 ]
机构
[1] Univ Teknol MARA, Cawangan Pulau Pinang, Elect Engn Studies, Coll Engn, George Town, Malaysia
来源
2024 IEEE 14TH SYMPOSIUM ON COMPUTER APPLICATIONS & INDUSTRIAL ELECTRONICS, ISCAIE 2024 | 2024年
关键词
intake system; peristaltic pump; water quality; flow rate; in-situ;
D O I
10.1109/ISCAIE61308.2024.10576544
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Water quality at specific places is normally assessed by collecting water samples at site and transporting them to the laboratory for testing purposes. For in situ measurement, a popular method of collecting the samples is by using a conventional sample test kit such as syringe and cuvette. This approach, however, requires human intervention and needs to be done manually. The need for a mechanism to improve the sampling technique is crucial for in situ measurement such as for microfluidic and point-of-care devices. The aim of this work is to propose an intake system with the capability of controlling the samples that flow into the testing system. The circuit is designed and simulated using TinkerCAD software to observe and analyze the electrical characteristics of the proposed system in which a peristaltic pump is used as the main component in the intake system. Based on simulation work, 100 Omega rheostat setting between 10 to 50% was found to be suitable to drive a 12 V motor (representing a peristaltic pump) and satisfy the minimum operating current of 106.5 mA. The intake system was successfully developed to be capable of controlling the flow rate of intake samples through rheostat setting. At this range of rheostat setting, voltage characteristics for simulated and actual setup show similar patterns with less than 7% deviation. Through experiment, the system produced a range of flow rates between 0.842 ml(3)/s to 1.7549 ml(3)/s at controlling voltage from 6.2073 V to 10.5731 V. The relationship between the controlling voltage and flow intake was determined as a preliminary effort to develop a voltage-controlled intake system for multipurpose in situ application. Further improvement can be made by translating this voltage into its respective flow rate for display purposes and by integrating a commercial flow sensor for verification. This preliminary work could contribute to the future development of an intake system that is capable of performing a continuous and segmented automatic sampling to improve the traditional way of sampling process, which is manually done.
引用
收藏
页码:478 / 481
页数:4
相关论文
共 50 条
  • [21] Water Quality Assessment and Mapping for Water Supply System of Abbottabad's Urban Settlements
    Pervez, Arshid
    Jamshed, Romana
    Nawab, Bahadar
    Shah, M. M.
    PAKISTAN JOURNAL OF ZOOLOGY, 2012, 44 (02) : 581 - 585
  • [22] Sustainable In-Situ Water Resource Management Strategies in Water Scarce Urban Environment
    Chengyao, Peng
    Shuying, Wang
    Jie, Zhang
    Chong, Lim Chin
    Kah, Ooi Lin
    2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [23] Preliminary assessment of the water quality of Rushikulya estuary based on the abundance of pathogenic bacteria
    Panda, Bhubaneswari
    Sundaray, Lokeshwara
    Mishra, Ankita
    Palai, Subhadarshani
    Padhi, Sanjukta Rani
    Patro, Shesdev
    Mohanty, Pratap Kumar
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2023, 195 (10)
  • [24] Preliminary assessment of the water quality of Rushikulya estuary based on the abundance of pathogenic bacteria
    Bhubaneswari Panda
    Lokeshwara Sundaray
    Ankita Mishra
    Subhadarshani Palai
    Sanjukta Rani Padhi
    Shesdev Patro
    Pratap Kumar Mohanty
    Environmental Monitoring and Assessment, 2023, 195
  • [25] A Smart Sensing System of Water Quality and Intake Monitoring for Livestock and Wild Animals
    Tang, Wei
    Biglari, Amin
    Ebarb, Ryan
    Pickett, Tee
    Smallidge, Samuel
    Ward, Marcy
    SENSORS, 2021, 21 (08)
  • [26] Real Time Embedded System for Assessment of Potable Water Quality
    Bhakare, Pradip R.
    Mathurkar, S. S.
    2017 IEEE INTERNATIONAL CONFERENCE ON POWER, CONTROL, SIGNALS AND INSTRUMENTATION ENGINEERING (ICPCSI), 2017, : 1393 - 1397
  • [27] Assessment and forecast of water quality in the River Ingulets irrigation system
    Lykhovyd, P. V.
    Kozlenko, Ye. V.
    UKRAINIAN JOURNAL OF ECOLOGY, 2018, 8 (01): : 350 - 355
  • [28] Water Quality Assessment Tool for On-Site Water Quality Monitoring
    Olatinwo, Segun O.
    Joubert, Trudi-H.
    IEEE SENSORS JOURNAL, 2024, 24 (10) : 16450 - 16466
  • [29] Water quality assessment in an arid region using a water quality index
    Varnosfaderany, M. Nemati
    Mirghaffary, N.
    Ebrahimi, E.
    Soffianian, A.
    WATER SCIENCE AND TECHNOLOGY, 2009, 60 (09) : 2319 - 2327
  • [30] The Geographical Information System (GIS) based water quality assessment of a drinking water distribution system in the Denizli City
    Koc, Abdullah Cem
    Ciner, Fehiman
    Toprak, Selcuk
    Selcuk, Huseyin
    Aktan, Burcu
    DESALINATION AND WATER TREATMENT, 2010, 19 (1-3) : 318 - 324