Preliminary Design of Water Intake System for In-situ Water Quality Assessment

被引:0
|
作者
Robi, Fatin Izyani Mohamad [1 ]
Abd Rahman, Mohamad Faizal [1 ]
Rohaizan, Azka [1 ]
Baharuddin, Rohaiza [1 ]
Abdullah, Mohd Hanapiah [1 ]
机构
[1] Univ Teknol MARA, Cawangan Pulau Pinang, Elect Engn Studies, Coll Engn, George Town, Malaysia
来源
2024 IEEE 14TH SYMPOSIUM ON COMPUTER APPLICATIONS & INDUSTRIAL ELECTRONICS, ISCAIE 2024 | 2024年
关键词
intake system; peristaltic pump; water quality; flow rate; in-situ;
D O I
10.1109/ISCAIE61308.2024.10576544
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Water quality at specific places is normally assessed by collecting water samples at site and transporting them to the laboratory for testing purposes. For in situ measurement, a popular method of collecting the samples is by using a conventional sample test kit such as syringe and cuvette. This approach, however, requires human intervention and needs to be done manually. The need for a mechanism to improve the sampling technique is crucial for in situ measurement such as for microfluidic and point-of-care devices. The aim of this work is to propose an intake system with the capability of controlling the samples that flow into the testing system. The circuit is designed and simulated using TinkerCAD software to observe and analyze the electrical characteristics of the proposed system in which a peristaltic pump is used as the main component in the intake system. Based on simulation work, 100 Omega rheostat setting between 10 to 50% was found to be suitable to drive a 12 V motor (representing a peristaltic pump) and satisfy the minimum operating current of 106.5 mA. The intake system was successfully developed to be capable of controlling the flow rate of intake samples through rheostat setting. At this range of rheostat setting, voltage characteristics for simulated and actual setup show similar patterns with less than 7% deviation. Through experiment, the system produced a range of flow rates between 0.842 ml(3)/s to 1.7549 ml(3)/s at controlling voltage from 6.2073 V to 10.5731 V. The relationship between the controlling voltage and flow intake was determined as a preliminary effort to develop a voltage-controlled intake system for multipurpose in situ application. Further improvement can be made by translating this voltage into its respective flow rate for display purposes and by integrating a commercial flow sensor for verification. This preliminary work could contribute to the future development of an intake system that is capable of performing a continuous and segmented automatic sampling to improve the traditional way of sampling process, which is manually done.
引用
收藏
页码:478 / 481
页数:4
相关论文
共 50 条
  • [1] In-situ turbidity sensor system for residential water quality monitoring
    Lee, Joohyun
    Kwon, Ji-Hwan
    Kim, Joohan
    Koo, Junemo
    Lee, Sooheyong
    INTERNATIONAL JOURNAL OF NANOTECHNOLOGY, 2024, 21 (03)
  • [2] Development of In-situ Sensing System and Classification of Water Quality using Machine Learning Approach
    Sukor, Abdul Syafiq Abdull
    Muhamad, Mohamad Naim
    Ab Wahab, Mohd Nadhir
    2022 IEEE 18TH INTERNATIONAL COLLOQUIUM ON SIGNAL PROCESSING & APPLICATIONS (CSPA 2022), 2022, : 382 - 385
  • [3] Combining Remote and In-situ Sensing for Persistent Monitoring of Water Quality
    Rojas, Cesar A.
    Reis, Gregory M.
    Albayrak, Arif R.
    Osmanoglu, Batuhan
    Bobadilla, Leonardo
    Smith, Ryan N.
    OCEANS 2022, 2022,
  • [4] PRELIMINARY ASSESSMENT OF WATER QUALITY FROM INTAKE POINT, THROUGH TREATMENT PLANT, UP TO RECEIVING BODY
    Wasag, Zbigniew
    ACTA SCIENTIARUM POLONORUM-FORMATIO CIRCUMIECTUS, 2008, 7 (03) : 43 - 50
  • [5] Baseline assessment of coastal water quality, in Vanuatu, South Pacific: Insights gained from in-situ sampling
    Devlin, Michelle
    Smith, Andy
    Graves, Carolyn A.
    Petus, Caroline
    Tracey, Dieter
    Maniel, Michael
    Hooper, Eryn
    Kotra, Krishna
    Samie, Erie
    Loubser, David
    Lyons, Brett P.
    MARINE POLLUTION BULLETIN, 2020, 160 (160)
  • [6] Design of Water Quality Monitoring System
    Feng, Chenwei
    Yuan, Jiangnan
    Sun, Yu
    You, Junming
    2020 INTERNATIONAL CONFERENCE ON ARTIFICIAL INTELLIGENCE AND COMPUTER ENGINEERING (ICAICE 2020), 2020, : 264 - 267
  • [7] The California Water Quality Assessment spatial database: A preliminary look at Sierra Nevada riverine water quality
    Pawley, AL
    Viers, JH
    Oshima, I
    Quinn, JF
    INTEGRATED ASSESSMENT OF ECOSYSTEM HEALTH, 2000, : 333 - 348
  • [8] In Situ Water Quality Measurements Using an Unmanned Aerial Vehicle (UAV) System
    Koparan, Cengiz
    Koc, Ali Bulent
    Privette, Charles V.
    Sawyer, Calvin B.
    WATER, 2018, 10 (03)
  • [9] Preliminary assessment and classification of the water quality of the Tarcoles and Reventazan river basin Part III: Quality of bodies receiving water according to the Dutch System of Evaluation
    Caivo Brenes, Guillermo
    Mora Molina, Jesus
    TECNOLOGIA EN MARCHA, 2007, 20 (04): : 59 - 67
  • [10] Optimal Design of Water Tank Size for Power System Flexibility and Water Quality
    Yao, Yiming
    Li, Chunyan
    Xie, Kaigui
    Tai, Heng-Ming
    Hu, Bo
    Niu, Tao
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2021, 36 (06) : 5874 - 5888