Calculation of Gamma-Ray buildup factors up to 100 MFP by the Monte Carlo method

被引:0
作者
Sun, Pei [1 ,2 ]
Xing, Liang [1 ,2 ]
Yin, Longtao [1 ,2 ]
Huang, Jianye [1 ,2 ]
Zhong, Bin [1 ]
Shen, Huayun [1 ]
Ying, Yangjun [1 ]
机构
[1] Inst Appl Phys & Computat Math, Beijing 100094, Peoples R China
[2] China Acad Engn Phys, Grad Sch, Beijing 100193, Peoples R China
关键词
Buildup factor; Monte Carlo method; Variance reduction technique; Point kernel method; DEPTHS;
D O I
10.1016/j.radphyschem.2025.112696
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The point-kernel method is an analytical calculation method used to evaluate gamma-ray radiation fields and is widely applied in the fields of radiation protection and shielding design. The buildup factor is a critical parameter in determining the accuracy of the point-kernel method. However, the standard buildup factor datasets are constrained by limited range and insufficient consideration of certain physical processes, which restricts the application of the point-kernel method. This study aims to calculate buildup factors up to 100 MFP based on detailed physical models and advanced variance reduction techniques. Extensive statistical checks are conducted to ensure that the results are strictly unbiased. Additionally, the impacts of physical models, geometric configurations, and dose types on buildup factors are further evaluated. When the detailed physical model is considered, the BUF shows a maximum increase of 523 times compared to the standard data, making the standard database no longer conservative. In the low-energy region of highly scattering medium, the impacts of geometric configurations and dose types on BUF are observed to reach up to 80 %similar to 90 %. Finally, the origins of conservatism in the point-kernel method are discussed. Validation and testing are conducted using a typical model on the data which exhibited significant differences from the standard dataset. The results indicated that the new data surpassed the standard dataset in both conservatism and accuracy.
引用
收藏
页数:10
相关论文
共 30 条
  • [1] Alipoor M, 2024, J MED PHYS, V49, P661, DOI 10.4103/jmp.jmp_91_24
  • [2] ANSI/ANS, 1991, Gamma ray attenuation coefficient and buildup factors for engineering materials. Gamma-Ray Attenuation Coefficients and Buildup Factors for Engineering Materials.
  • [3] The Failure of Monte Carlo Radiative Transfer at Medium to High Optical Depths
    Camps, Peter
    Baes, Maarten
    [J]. ASTROPHYSICAL JOURNAL, 2018, 861 (02)
  • [4] New photon exposure buildup factors
    Chibani, O
    [J]. NUCLEAR SCIENCE AND ENGINEERING, 2001, 137 (02) : 215 - 225
  • [5] Goldstein H., 1954, CALCULATIONS PENETRA
  • [6] Grady H.H., 2015, LA-UR-13-27377
  • [7] Monte Carlo electron transport simulation study based on NPTS program
    Han, Lihui
    Zhang, Huayang
    Zhong, Bin
    Cheng, Li
    Shen, Huayun
    [J]. PROGRESS IN NUCLEAR ENERGY, 2023, 158
  • [8] AN HISTORICAL REVIEW AND CURRENT STATUS OF BUILDUP FACTOR CALCULATIONS AND APPLICATIONS
    HARIMA, Y
    [J]. RADIATION PHYSICS AND CHEMISTRY, 1993, 41 (4-5): : 631 - 672
  • [9] IMPROVEMENT OF THE GEOMETRIC-PROGRESSION FORMULA FOR APPROXIMATING GAMMA-RAY BUILDUP FACTORS UP TO DEPTHS OF 100 mfp
    Harima, Yoshiko
    Sakamoto, Yukio
    Kurosawa, Naohiro
    Shimizu, Akinao
    [J]. NUCLEAR TECHNOLOGY, 2009, 168 (03) : 861 - 866
  • [10] Hubbell JH., 1995, TABLES XRAY MASS ATT, DOI DOI 10.18434/T4D01F