Physical and chemical changes of clear aligners after thermoforming and intraoral exposure

被引:0
作者
Dalaie, Kazem [1 ]
Rafsanjan, Katayoun Talebi [1 ]
Nojehdehian, Hanieh [2 ]
Namazi, Zahra [2 ]
机构
[1] Shahid Beheshti Univ Med Sci, Dept Orthodont, Tehran, Iran
[2] Shahid Beheshti Univ Med Sci, Dept Dent Biomat, Tehran, Iran
关键词
Clear aligner appliances; Hardness; X-Ray diffraction; Spectroscopy; Fourier transform infrared; Glass transition; Thermoforming; THERMOPLASTIC MATERIALS; MECHANICAL-PROPERTIES; FORCE;
D O I
10.25259/APOS_169_2023
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study assessed the physical and chemical changes of clear aligners after thermoforming and intraoral exposure. Material and Methods: This ex vivo study evaluated raw sheets, thermoformed sheets, and aligners used for 2 weeks from two commercial brands of Erkodur and Shinseki (n = 8 in each group). The surface hardness (by the Vickers hardness test), thickness (by a digital caliper), and glass transition temperature (Tg) (by differential scanning calorimetry) of the specimens were measured, and they underwent X-ray diffraction (XRD) to assess their degree of crystallinity and attenuated total reflectance-Fourier-transform infrared spectroscopy (ATR-FTIR) for analysis of their molecular composition. Data were analyzed by one-sample, paired and independent t-tests, and Mann-Whitney U and Wilcoxon signed-rank tests (alpha = 0.05). Results: The XRD and ATR-FTIR spectra of Erkodur and Shinseki aligners matched those of polyethylene terephthalate glycol polymer and did not change after thermoforming or intraoral exposure. Unlike intraoral exposure (P > 0.05), thermoforming significantly decreased the hardness of both brands of aligners (P < 0.05). Intraoral exposure significantly decreased the thickness of Erkodur aligners at some points and significantly increased the thickness of Shinseki aligners (P < 0.05). Thermoforming significantly decreased the Tg of both brands of aligners (P < 0.05). Intraoral exposure significantly decreased the Tg of Erkodur and increased the Tg of Shinseki aligners (P = 0.000). Conclusion: Erkodur and Shinseki aligners showed high chemical and structural stability after thermoforming and 2 weeks of intraoral exposure. However, thermoforming affected the thermal and physical properties of both brands of aligners. Erkodur aligners had higher dimensional stability than Shinseki aligners.
引用
收藏
页码:235 / 247
页数:13
相关论文
共 32 条
  • [1] Structural Conformation Comparison of Different Clear Aligner Systems: An In Vitro Study
    Alhendi, Aseel
    Khounganian, Rita
    Ali, Raisuddin
    Syed, Saeed Ali
    Almudhi, Abdullazez
    [J]. DENTISTRY JOURNAL, 2022, 10 (05)
  • [2] Mechanical and Geometrical Properties Assessment of Thermoplastic Materials for Biomedical Application
    Barone, Sandro
    Paoli, Alessandro
    Neri, Paolo
    Razionale, Armando Viviano
    Giannese, Michele
    [J]. ADVANCES ON MECHANICS, DESIGN ENGINEERING AND MANUFACTURING, 2017, : 436 - 445
  • [3] Advances in orthodontic clear aligner materials
    Bichu, Yashodhan M.
    Alwafi, Abdulraheem
    Liu, Xiaomo
    Andrews, James
    Ludwig, Bjoern
    Bichu, Aditi Y.
    Zou, Bingshuang
    [J]. BIOACTIVE MATERIALS, 2023, 22 : 384 - 403
  • [4] Do the mechanical and chemical properties of Invisalign™ appliances change after use? A retrieval analysis
    Bradley, T. Gerard
    Teske, Lauren
    Eliades, George
    Zinelis, Spiros
    Eliades, Theodore
    [J]. EUROPEAN JOURNAL OF ORTHODONTICS, 2016, 38 (01) : 27 - 31
  • [5] Thickness of orthodontic clear aligners after thermoforming and after 10 days of intraoral exposure: a prospective clinical study
    Bucci, Rosaria
    Rongo, Roberto
    Levate, Carmine
    Michelotti, Ambrosina
    Barone, Sandro
    Razionale, Armando Viviano
    D'Anto, Vincenzo
    [J]. PROGRESS IN ORTHODONTICS, 2019, 20 (01)
  • [6] Coba Salcedo MF, 2018, Contemp Eng Sci, V11, P3771
  • [7] Mechanical properties of "two generations" of teeth aligners: Change analysis during oral permanence
    Condo, Roberta
    Pazzini, Luca
    Cerroni, Loredana
    Pasquantoni, Guido
    Lagana, Giuseppina
    Pecora, Alessandro
    Mussi, Valentina
    Rinaldi, Antonio
    Mecheri, Barbara
    Licoccia, Silvia
    Maiolo, Luca
    [J]. DENTAL MATERIALS JOURNAL, 2018, 37 (05) : 835 - 842
  • [8] Dynamic mechanical and thermal properties of clear aligners after thermoforming and aging
    Dalaie, Kazem
    Fatemi, Seyyed Mostafa
    Ghaffari, Samin
    [J]. PROGRESS IN ORTHODONTICS, 2021, 22 (01)
  • [9] Color Stability, Chemico-Physical and Optical Features of the Most Common PETG and PU Based Orthodontic Aligners for Clear Aligner Therapy
    Daniele, Valeria
    Macera, Ludovico
    Taglieri, Giuliana
    Spera, Loredana
    Marzo, Giuseppe
    Quinzi, Vincenzo
    [J]. POLYMERS, 2022, 14 (01)
  • [10] Thermoplastic Disks Used for Commercial Orthodontic Aligners: Complete Physicochemical and Mechanical Characterization
    Daniele, Valeria
    Macera, Ludovico
    Taglieri, Giuliana
    Di Giambattista, Alessandra
    Spagnoli, Giuseppe
    Massaria, Alessandra
    Messori, Massimo
    Quagliarini, Enrico
    Chiappini, Gianluca
    Campanella, Vincenzo
    Mummolo, Stefano
    Marchetti, Enrico
    Marzo, Giuseppe
    Quinzi, Vincenzo
    [J]. MATERIALS, 2020, 13 (10)