Eye-movement artifact correction in infant EEG: A systematic comparison between ICA and Artifact Blocking

被引:0
|
作者
Srishyla, Diksha [1 ,2 ,3 ,4 ]
Webb, Sara Jane [5 ]
Elsabbagh, Mayada [1 ]
O'Reilly, Christian [1 ,2 ,3 ,4 ]
机构
[1] McGill Univ, Montreal Neurol Inst, Montreal, PQ, Canada
[2] Univ South Carolina, Comp Sci & Engn, Columbia, SC 29208 USA
[3] Univ South Carolina, Artificial Intelligence Inst, Columbia, SC 29208 USA
[4] Univ South Carolina, Carolina Autism & Neurodev Res Ctr, Columbia, SC 29208 USA
[5] Seattle Childrens Res Inst, Ctr Child Hlth Behav & Dev, Seattle, WA USA
基金
英国医学研究理事会;
关键词
Independent component analysis; Artifact blocking; Electroencephalogram; Eye-movement artifact; Infants; ENTROPY;
D O I
10.1016/j.jneumeth.2025.110405
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Independent Component Analysis (ICA) is a well-established approach to clean EEG and remove the impact of signals of non-neural origin, such as those from muscular activity and eye movements. However, evidence suggests that ICA removes artifacts less effectively in infants than in adults. This study systematically compares ICA and Artifact Blocking (AB), an alternative approach proposed to improve eye-movement artifact correction in infant EEG. Methods: We analyzed EEG collected from 50 infants between 6 and 18 months of age as part of the International Infant EEG Data Integration Platform (EEG-IP), a longitudinal multi-study dataset. EEG was recorded while infants sat on their caregivers' laps and watched videos. We used ICA and AB to correct for eye-movement artifacts in the EEG and calculated the proportion of effectively corrected segments, signal-to-noise ratio (SNR), power-spectral density (PSD), and multiscale entropy (MSE) in manually selected EEG segments with and without eye-movement artifacts. Results: On the one hand, the proportion of effectively corrected segments indicated that ICA corrected eye-movement artifacts (sensitivity) better than AB. SNR and PSD indicated that both AB and ICA correct eye-movement artifacts with equal sensitivity. MSE gave mixed results. On the other hand, AB caused less distortion to the clean segments (specificity) for SNR, PSD, and MSE. Conclusion: Our results suggest that ICA is more sensitive (i.e., it better removes artifacts) but less specific (it distorts clean signals) than AB for correcting eye-movement artifacts in infant EEG.
引用
收藏
页数:10
相关论文
共 45 条
  • [1] EYE-MOVEMENT ARTIFACT COMPENSATION FOR EVOKED-RESPONSE EEG
    LEIFER, LJ
    OTTO, DA
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1974, 37 (02): : 210 - 211
  • [2] THE ASSESSMENT OF 2 METHODS FOR REMOVING EYE-MOVEMENT ARTIFACT FROM THE EEG
    JERVIS, BW
    NICHOLS, MJ
    ALLEN, EM
    HUDSON, NR
    JOHNSON, TE
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1985, 61 (05): : 444 - 452
  • [3] EYE MOVEMENT ARTIFACT IN CLINICAL EEG
    ROBINSON, TW
    JOHNSON, EO
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1965, 19 (01): : 104 - &
  • [4] ELECTRORETINOGRAPHY AND NYSTAGMUS - SUBTRACTION OF EYE-MOVEMENT ARTIFACT
    COUPLAND, SG
    KIRKHAM, TH
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 1981, 16 (04): : 192 - 194
  • [5] SOURCES OF ARTIFACT IN INFRARED RECORDING OF EYE-MOVEMENT
    TRUONG, DM
    FELDON, SE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1987, 28 (06) : 1018 - 1022
  • [6] THE REMOVAL OF THE EYE-MOVEMENT ARTIFACT FROM THE EEG BY REGRESSION-ANALYSIS IN THE FREQUENCY-DOMAIN
    WOESTENBURG, JC
    VERBATEN, MN
    SLANGEN, JL
    BIOLOGICAL PSYCHOLOGY, 1983, 16 (1-2) : 127 - 147
  • [7] Using an eye tracker for accurate eye movement artifact correction
    Kierkels, Joep J. M.
    Riani, Jamal
    Bergmans, Jan W. M.
    van Boxtel, Geert J. M.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (07) : 1256 - 1267
  • [8] An ICA-based method for automatic eye blink artifact correction in multi-channel EEG
    Zhu, Dan-hua
    Tong, Ji-jun
    Chen, Yu-quan
    2008 INTERNATIONAL SPECIAL TOPIC CONFERENCE ON INFORMATION TECHNOLOGY AND APPLICATIONS IN BIOMEDICINE, VOLS 1 AND 2, 2008, : 479 - 482
  • [9] EYE-MOVEMENT ARTIFACT NULLING IN EEGS BY MULTICHANNEL ONLINE EOG SUBTRACTION
    BARLOW, JS
    REMOND, A
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1981, 52 (05): : 418 - 423
  • [10] DIGITAL SUBTRACTION OF EYE-MOVEMENT ARTIFACT FROM PATTERN ERG RECORDINGS
    COUPLAND, SG
    KIRKHAM, TH
    NEURO-OPHTHALMOLOGY, 1983, 3 (04) : 281 - 284