Rapid urbanization has led to a significant urban heat island effect. When the spray cooling system is applied to outdoor public space, it is helpful to improve the microclimate. While a reasonable spray system is an important guarantee to improve the thermal comfort of the human body in the spray space. In this study, the combination of experimental measurement and questionnaire survey was used to explore the thermal comfort index suitable for evaluating natural and spray space to modify the heat stress scale. The accuracy of thermal sensation prediction based on the original thermal comfort index and the corresponding heat stress scale was compared between the two methods of thermal sensation regression and thermal unacceptable percentage prediction. A heat stress scale based on natural and spray space in Qingdao was proposed. The results showed that compared with direct exposure to sunlight, the spray space could effectively improve thermal sensation (-1.07) and thermal comfort (+0.80), and inhibit the rate of skin temperature rise (+0.553 similar to -0.155 degrees C/min). The thermal unacceptable percentage method can be used to predict the thermal sensation in the natural space, and the prediction rate (88 %) of the universal thermal climate index (UTCI) was the highest. The thermal sensation regression method can be used to predict the thermal sensation in the spray space, and the standard effective temperature (SET*) prediction rate (60 %) was the highest. In the assessment of outdoor thermal risk, when the UTCI exceeded 38 degrees C in Qingdao, the heat risk reached the range of strong heat stress, and it was necessary to start the spray device to improve the thermal environment. When the SET* in the spray space exceeded 41 degrees C, the spray still cannot improve the thermal health status, and it was recommended to reduce outdoor activities.
引用
收藏
页数:18
相关论文
共 40 条
[1]  
[Anonymous], 1998, ISO 7726
[2]  
[Anonymous], 1995, ASHRAE Handbook
[3]  
[Anonymous], 2017, ASHRAE STANDARD 55 2
[4]   Solar energy powering up aerial misting systems for cooling surroundings in Saudi Arabia [J].
Atieh, Ahmad ;
Al Shariff, Samir .
ENERGY CONVERSION AND MANAGEMENT, 2013, 65 :670-674
[5]   Human calorimetry II. The average temperature of the tissues of the body [J].
Burton, AC .
JOURNAL OF NUTRITION, 1935, 9 (03) :261-280
[6]   The synergistic effects of air pollution and urban heat island on public health: A gender-oriented nationwide study of China [J].
Chen, Shuangzhou ;
Bao, Zhikang ;
Ou, Yifu ;
Chen, Ke .
URBAN CLIMATE, 2023, 51
[7]   Experimental evaluation of a water spray system for semi-outdoor spaces: Analysis of the effect of the operational parameters [J].
Coccia, Gianluca ;
Summa, Serena ;
Di Giuseppe, Elisa ;
D'Orazio, Marco ;
Zinzi, Michele ;
Di Perna, Costanzo .
BUILDING AND ENVIRONMENT, 2023, 241
[8]   The spatial comfort and thermal delight of outdoor misting installations in hot and humid extreme environments [J].
Desert, Aimee ;
Naboni, Emanuele ;
Garcia, David .
ENERGY AND BUILDINGS, 2020, 224
[9]   Attenuation of solar radiation by a water mist from the ultraviolet to the infrared range [J].
Dombrovsky, Leonid A. ;
Solovjov, Vladimir P. ;
Webb, Brent W. .
JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2011, 112 (07) :1182-1190
[10]   Study of mist-cooling for semi-enclosed spaces in Osaka, Japan [J].
Farnham, Craig ;
Nakao, Masaki ;
Nishioka, Masatoshi ;
Nabeshima, Minako ;
Mizuno, Takeo .
URBAN ENVIRONMENTAL POLLUTION 2010, 2011, 4 :228-238