Lateralization and Distalization Shoulder Angles in Reverse Shoulder Arthroplasty: Are They Still Reliable and Accurate in All Patients and for All Prosthetic Designs?

被引:0
作者
Sahin, Koray [1 ]
Kaya, Hakan Batuhan [1 ]
Koukos, Christos [2 ]
Kapicioglu, Mehmet [1 ]
Bilsel, Kerem [3 ]
机构
[1] Bezmialem Vakif Univ, Dept Orthoped & Traumatol, TR-34093 Istanbul, Turkiye
[2] Sports Trauma & Pain Inst, Thessaloniki 54655, Greece
[3] Acibadem Univ, Dept Orthoped & Traumatol, Fulya Hosp, TR-34349 Istanbul, Turkiye
关键词
reverse shoulder arthroplasty; lateralization shoulder angle; distalization shoulder angle; critical shoulder angle; acromial index; CUFF;
D O I
10.3390/jcm14041393
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Recently, the lateralization shoulder angle (LSA) and distalization shoulder angle (DSA) have been proposed to assess lateralization and distalization in reverse shoulder arthroplasty (RSA). However, there is insufficient evidence about the influence of patient anatomy and prosthesis design on these measurements. This study aims to investigate the impact of patient anatomy and implant design on LSA and DSA measurements and to assess the validity of the previously reported "optimal" ranges for these parameters. Methods: Patients who underwent the RSA procedure using four different prosthetic designs between April 2014 and June 2023 were retrospectively evaluated. Postoperative LSA and DSA measurements were compared according to implant design, preoperative glenoid morphology (Favard classification), and the Hamada grade. The correlation of LSA and DSA with preoperative shoulder anatomy (critical shoulder angle, CSA, and acromial index, AI) was also assessed. Results: In total, 135 shoulders were included in the study, with a mean age of 71.7 +/- 7.9 years. The mean LSA was 88.4 +/- 11.8 degrees and mean DSA was 40.6 +/- 12.5 degrees. According to prosthetic design, both mean LSA and DSA values differed significantly (p < 0.05). Lateralized designs (Groups I and IV) had significantly higher mean LSA values. The Favard classification and Hamada grade of shoulders did not show a significant influence on LSA and DSA measurements (p > 0.05). DSA was observed to be significantly correlated with CSA and AI (p < 0.05; r = -0.27 and -0.189, respectively). Conclusions: Prosthetic design and preoperative shoulder anatomy had a significant influence on LSA and DSA measurements in RSA. Optimal LSA and DSA values may lack validity and reliability and should not be applied to all patients.
引用
收藏
页数:11
相关论文
共 20 条
[1]  
Best M.J., Aziz K.T., Wilckens J.H., McFarland E.G., Srikumaran U., Increasing Incidence of Primary Reverse and Anatomic Total Shoulder Arthroplasty in the United States, J. Shoulder Elbow Surg, 30, pp. 1159-1166, (2021)
[2]  
Grammont P., Trouilloud P., Laffay J.P., Deries X., Etude et Réalisation d’une Nouvelle Prothèse d’épaule, Rhumatologie (Aix-Bains), 39, pp. 407-418, (1987)
[3]  
Mizuno N., Denard P.J., Raiss P., Walch G., The Clinical and Radiographical Results of Reverse Total Shoulder Arthroplasty with Eccentric Glenosphere, Int. Orthop, 36, pp. 1647-1653, (2012)
[4]  
Boileau P., Watkinson D.J., Hatzidakis A.M., Balg F., Grammont Reverse Prosthesis: Design, Rationale, and Biomechanics, J. Shoulder Elbow Surg, 14, pp. 147S-161S, (2005)
[5]  
Boileau P., Moineau G., Roussanne Y., O'Shea K., Bony Increased-Offset Reversed Shoulder Arthroplasty: Minimizing Scapular Impingement While Maximizing Glenoid Fixation, Clin. Orthop. Relat. Res, 469, pp. 2558-2567, (2011)
[6]  
Ladermann A., Denard P.J., Boileau P., Farron A., Deransart P., Terrier A., Ston J., Walch G., Effect of Humeral Stem Design on Humeral Position and Range of Motion in Reverse Shoulder Arthroplasty, Int. Orthop, 39, pp. 2205-2213, (2015)
[7]  
Berliner J.L., Regalado-Magdos A., Ma C.B., Feeley B.T., Biomechanics of Reverse Total Shoulder Arthroplasty, J. Shoulder Elbow Surg, 24, pp. 150-160, (2015)
[8]  
Katz D., Valenti P., Kany J., Elkholti K., Werthel J.-D., Does Lateralisation of the Centre of Rotation in Reverse Shoulder Arthroplasty Avoid Scapular Notching? Clinical and Radiological Review of One Hundred and Forty Cases with Forty Five Months of Follow-Up, Int. Orthop, 40, pp. 99-108, (2016)
[9]  
Greiner S., Schmidt C., Herrmann S., Pauly S., Perka C., Clinical Performance of Lateralized versus Non-Lateralized Reverse Shoulder Arthroplasty: A Prospective Randomized Study, J. Shoulder Elbow Surg, 24, pp. 1397-1404, (2015)
[10]  
Ladermann A., Williams M.D., Melis B., Hoffmeyer P., Walch G., Objective Evaluation of Lengthening in Reverse Shoulder Arthroplasty, J. Shoulder Elbow Surg, 18, pp. 588-595, (2009)