The Updated Registry of Fast Myocardial Perfusion Imaging with Next-Generation SPECT (REFINE SPECT 2.0)

被引:1
|
作者
Miller, Robert J. H. [1 ,2 ,3 ,4 ,5 ]
Lemley, Mark [1 ,2 ,3 ]
Shanbhag, Aakash [1 ,2 ,3 ]
Ramirez, Giselle [1 ,2 ,3 ]
Liang, Joanna X. [1 ,2 ,3 ]
Builoff, Valerie [1 ,2 ,3 ]
Kavanagh, Paul [1 ,2 ,3 ]
Sharir, Tali [6 ,7 ]
Hauser, M. Timothy [8 ]
Ruddy, Terrence D. [9 ]
Fish, Mathews B. [10 ]
Bateman, Timothy M. [11 ]
Acampa, Wanda [12 ]
Einstein, Andrew J. [13 ,14 ,15 ]
Dorbala, Sharmila [16 ]
Carli, Marcelo F. [9 ]
Feher, Attila [17 ]
Miller, Edward J. [17 ]
Sinusas, Albert J. [17 ]
Halcox, Julian [18 ]
Martins, Monica [18 ]
Kaufmann, Philipp A. [19 ]
Dey, Damini [1 ,2 ,3 ]
Berman, Daniel S. [1 ,2 ,3 ]
Slomka, Piotr J. [1 ,2 ,3 ]
机构
[1] Cedars Sinai Med Ctr, Dept Med, Div Artificial Intelligence Med, Los Angeles, CA 90048 USA
[2] Cedars Sinai Med Ctr, Dept Biomed Sci, Div Artificial Intelligence Med, Los Angeles, CA 90048 USA
[3] Cedars Sinai Med Ctr, Dept & Imaging, Div Artificial Intelligence Med, Los Angeles, CA 90048 USA
[4] Univ Calgary, Dept Cardiac Sci, Calgary, AB, Canada
[5] Libin Cardiovasc Inst, Calgary, AB, Canada
[6] Assuta Med Ctr, Dept Nucl Cardiol, Tel Aviv, Israel
[7] Ben Gurion Univ Negev, Beer Sheva, Israel
[8] Oklahoma Heart Hosp, Dept Nucl Cardiol, Oklahoma City, OK USA
[9] Univ Ottawa Heart Inst, Div Cardiol, Ottawa, ON, Canada
[10] Oregon Heart & Vasc Inst, Sacred Heart Med Ctr, Springfield, OR USA
[11] Cardiovasc Imaging Technol LLC, Kansas City, MO USA
[12] Univ Naples Federico II, Dept Adv Biomed Sci, Naples, Italy
[13] Columbia Univ, Irving Med Ctr, Dept Med, Div Cardiol, New York, NY USA
[14] Columbia Univ, Irving Med Ctr, Dept Radiol, New York, NY USA
[15] New York Presbyterian Hosp, New York, NY USA
[16] Brigham & Womens Hosp, Dept Radiol, Div Nucl Med & Mol Imaging, Boston, MA USA
[17] Yale Univ, Sch Med, Dept Internal Med, Sect Cardiovasc Med, New Haven, CT USA
[18] UK Swansea Univ, Med Sch, Swansea, Wales
[19] Univ Hosp Zurich, Dept Nucl Med, Cardiac Imaging, Zurich, Switzerland
基金
美国国家卫生研究院;
关键词
SPECT; solid-state detector; myocardial perfusion imag- ing; coronary artery disease; artificial intelligence; quantitative analysis; RISK;
D O I
10.2967/jnumed.124.268292
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The Registry of Fast Myocardial Perfusion Imaging with Next- Generation SPECT (REFINE SPECT) has been expanded to include more patients and CT attenuation correction imaging. We present the design and initial results from the updated registry. Methods: The updated REFINE SPECT is a multicenter, international registry with clinical data and image files. SPECT images were processed by quantitative software and CT images by deep learning software detecting coronary artery calcium (CAC). Patients were followed for major adverse cardiovascular events (MACEs) (death, myocardial infarction, unstable angina, late revascularization). Results: The registry included scans from 45,252 patients from 13 centers (55.9% male, 64.7 6 11.8 y). Correlating invasive coronary angiography was available for 3,786 (8.4%) patients. CT attenuation correction imaging was available for 13,405 patients. MACEs occurred in 6,514 (14.4%) patients during a median follow-up of 3.6 y (interquartile range, 2.5- 4.8 y). Patients with a stress total perfusion deficit of 5% to less than 10% (unadjusted hazard ratio [HR], 2.42; 95% CI, 2.23-2.62) and a stress total perfusion deficit of at least 10% (unadjusted HR, 3.85; 95% CI, 3.56-4.16) were more likely to experience MACEs. Patients with a deep learning CAC score of 101-400 (unadjusted HR, 3.09; 95% CI, 2.57-3.72) and a CAC of more than 400 (unadjusted HR, 5.17; 95% CI, 4.41-6.05) were at increased risk of MACEs. Conclusion: The REFINE SPECT registry contains a comprehensive set of imaging and clinical variables. It will aid in understanding the value of SPECT myocardial perfusion imaging, leverage hybrid imaging, and facilitate validation of new artificial intelligence tools for improving prediction of adverse outcomes incorporating multimodality imaging.
引用
收藏
页码:1795 / 1801
页数:7
相关论文
共 50 条
  • [1] Rationale and design of the REgistry of Fast Myocardial Perfusion Imaging with NExt generation SPECT (REFINE SPECT)
    Piotr J. Slomka
    Julian Betancur
    Joanna X. Liang
    Yuka Otaki
    Lien-Hsin Hu
    Tali Sharir
    Sharmila Dorbala
    Marcelo Di Carli
    Mathews B. Fish
    Terrence D. Ruddy
    Timothy M. Bateman
    Andrew J. Einstein
    Philipp A. Kaufmann
    Edward J. Miller
    Albert J. Sinusas
    Peyman N. Azadani
    Heidi Gransar
    Balaji K. Tamarappoo
    Damini Dey
    Daniel S. Berman
    Guido Germano
    Journal of Nuclear Cardiology, 2020, 27 : 1010 - 1021
  • [2] The next step in standardizing SPECT myocardial perfusion imaging
    J. D. van Dijk
    P. L. Jager
    J. A. van Dalen
    Journal of Nuclear Cardiology, 2021, 28 : 234 - 235
  • [3] The next step in standardizing SPECT myocardial perfusion imaging
    van Dijk, J. D.
    Jager, P. L.
    van Dalen, J. A.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2021, 28 (01) : 234 - 235
  • [4] Can we “REFINE” the art of predicting ischemia on SPECT myocardial perfusion imaging?
    Karthik Ananthasubramaniam
    Parthiban Arumugam
    Journal of Nuclear Cardiology, 2022, 29 : 3233 - 3235
  • [5] Can we "REFINE" the art of predicting ischemia on SPECT myocardial perfusion imaging?
    Ananthasubramaniam, Karthik
    Arumugam, Parthiban
    JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (06) : 3233 - 3235
  • [6] Prognostic safety of automatic cancellation of rest myocardial perfusion scan by machine learning: a report from multicenter REFINE SPECT registry of new generation SPECT
    Hu, L.
    Sharir, T.
    Fish, M. B.
    Ruddy, T. D.
    Di Carli, M.
    Dorbala, S.
    Einstein, J.
    Betancur, J.
    Eisenberg, E.
    Commandeur, F.
    Germano, G.
    Damini, D.
    Berman, D.
    Slomka, P. J.
    EUROPEAN HEART JOURNAL, 2019, 40 : 3 - 3
  • [7] Machine learning predicts per-vessel early coronary revascularization after fast myocardial perfusion SPECT: results from multicentre REFINE SPECT registry
    Hu, Lien-Hsin
    Betancur, Julian
    Sharir, Tali
    Einstein, Andrew J.
    Bokhari, Sabahat
    Fish, Mathews B.
    Ruddy, Terrence D.
    Kaufmann, Philipp A.
    Sinusas, Albert J.
    Miller, Edward J.
    Bateman, Timothy M.
    Dorbala, Sharmila
    Di Carli, Marcelo
    Germano, Guido
    Commandeur, Frederic
    Liang, Joanna X.
    Otaki, Yuka
    Tamarappoo, Balaji K.
    Dey, Damini
    Berman, Daniel S.
    Slomka, Piotr J.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2020, 21 (05) : 549 - 559
  • [8] Underuse of Appropriate SPECT Myocardial Perfusion Imaging Based on the Appropriateness Criteria for SPECT Myocardial Perfusion Imaging
    Daniel, William C.
    Spertus, John
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A368 - A368
  • [9] Quantitative Analysis of Fast Myocardial Perfusion Imaging with D-SPECT: Comparison to Conventional SPECT
    Ben-Haim, S.
    Sharir, T.
    Hutton, B. F.
    Van Gramberg, D.
    Prvulovich, E. M.
    Bomanji, J. B.
    Groves, A. M.
    Waddington, W. A.
    Dickman, D.
    Ell, P. J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S160 - S160
  • [10] Machine learning predicts early coronary revascularization after fast myocardial SPECT: results from multicenter REFINE SPECT registry
    Hu, Lien-Hsin
    Betancur, Julian
    Sharir, Tali
    Einstein, Andrew
    Fish, Mathews
    Ruddy, Terrence
    Kaufmann, Philipp
    Sinusas, Albert
    Miller, Edward
    Bateman, Timothy
    Dorbala, Sharmila
    Carli, Marcelo
    Germano, Guido
    Otaki, Yuka
    Tamarappoo, Balaji
    Dey, Damini
    Berman, Daniel
    Slomka, Piotr
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59