Effects of Inc parameter on quality of VMAT radiotherapy plans for right breast cancer based on dosimetric study

被引:0
|
作者
Shen, Chong [1 ]
Liao, Hailong [1 ]
Wang, Qi [1 ]
Liu, Hai [1 ]
Sun, Xiaonan [1 ]
机构
[1] Zhejiang Univ, Sch Med, Sir Run Run Shaw Hosp, Dept Radiat Oncol, Hangzhou 310016, Peoples R China
关键词
breast cancer; dosimetry; increment of gantry; radiotherapy; VMAT; THERAPY; IRRADIATION; ARC;
D O I
10.1097/MD.0000000000040125
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study aimed to investigate the influence of gantry angle increment (Inc) parameters on the Monaco treatment planning system for volumetric modulated arc therapy (VMAT) in right breast cancer, and to determine the optimal Inc parameters. Twenty-three patients with right breast cancer at the Sir Run Run Shaw Hospital from August 2022 to August 2023 were retrospectively selected. Four VMAT plans were generated for each patient incorporating Inc of 10 degrees, 20 degrees (control group), 30 degrees, and 40 degrees, while the other optimization parameters and constraint functions remained constant. The D98 and conformity index were lower in the Inc30 and Inc40 groups than in the Inc20 group. As Inc increased from 10 degrees to 30 degrees, the irradiated dose to the ipsilateral lung, including the V20, V5, and Dmax, mean dose, gradually increased. There were no statistically significant differences in the irradiated dose to the contralateral breast, contralateral lung, heart, esophagus, and brachial plexus. The number of monitor units and control points decreased with increasing Inc. Smaller Inc values can achieve higher target coverage and lower irradiated dose to the ipsilateral lung, but will reduce delivery efficiency. Considering the plan quality and delivery efficiency, an Inc of 10 degrees or 20 degrees is recommended for right breast cancer VMAT plans.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Evaluation of 3D-CRT, IMRT and VMAT radiotherapy plans for left breast cancer based on clinical dosimetric study
    Liu, Haiyun
    Chen, Xinde
    He, Zhijian
    Li, Jun
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2016, 54 : 1 - 5
  • [2] Comparative dosimetric study of h-IMRT and VMAT plans for breast cancer after breast-conserving surgery
    Zhang, Min
    Zhang, Fang-Xu
    Yang, Xiao-Lei
    Liang, Qian
    Liu, Jian
    Zhou, Wei-Bing
    TRANSLATIONAL ONCOLOGY, 2024, 47
  • [3] Dosimetric evaluation of right coronary artery in radiotherapy for breast cancer
    Altinok, Ayse
    Askeroglu, Orbay
    Doyuran, Mine
    Caglar, Mustafa
    Canturk, Emir
    Erol, Cengiz
    Bese, Nuran
    MEDICAL DOSIMETRY, 2019, 44 (03) : 205 - 209
  • [4] Dosimetric effects of anatomical deformations and positioning errors in VMAT breast radiotherapy
    Rossi, Maija
    Boman, Eeva
    Skytta, Tanja
    Haltamo, Mikko
    Laaksomaa, Marko
    Kapanen, Mika
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (05): : 506 - 516
  • [5] Dosimetric Investigation of FIF, VMAT, IMRT, H-VMAT, and H-IMRT Planning Techniques in Breast Cancer Radiotherapy
    Canbolat, Hilal Sarac
    Demircan, Niyazi Volkan
    Dinc, Serap Catli
    Senturk, Ertugrul
    Bora, Huseyin
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2023, 38 (01): : 45 - 51
  • [6] A comparative dosimetric study of left sided breast cancer after breast-conserving surgery treated with VMAT and IMRT
    Zhao, Hongfu
    He, Mingyuan
    Cheng, Guanghui
    Han, Dongmei
    Wu, Ning
    Shi, Dan
    Zhao, Zhipeng
    Jin, Jianxue
    RADIATION ONCOLOGY, 2015, 10
  • [7] Dosimetric evaluation of the benefit of deep inspiration breath hold (DIBH) for locoregional irradiation of right breast cancer with volumetric modulated arctherapy (VMAT)
    Loap, Pierre
    Vu-Bezin, Jeremi
    Monceau, Virginie
    Jacob, Sophie
    Fourquet, Alain
    Kirova, Youlia
    ACTA ONCOLOGICA, 2023, 62 (02) : 150 - 158
  • [8] Dosimetric Comparison of 3DCRT, IMRT and VMAT for Spine Radiotherapy based on Secondary Cancer Risk
    Rehman, Jalil ur
    Ashraf, J.
    Isa, Muhammad
    Afzal, Muhammad
    Ibbott, G.
    Chow, James
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 633 - 636
  • [9] The Effect of the Number of Fields on Radiotherapy Plans of Breast Cancer Patients in Three-Dimensionally Conformal Radiotherapy Plans: Dosimetric Studies
    Bazeed, Zezy Mansour
    Attalla, Ehab Maarouf
    Awad, Ibrahim Ali Mohamed
    Hamid, Maysa Ismail Abdel
    Sarhan, Afaf
    MIDDLE EAST JOURNAL OF CANCER, 2021, 12 (04) : 516 - 526
  • [10] Dosimetric analysis of half-field-based VMAT with the deep inspiration breath-hold technique for left breast cancer patients following breast-conserving surgery
    Wu, Weiwei
    Yin, Hui
    Liu, Zhiwei
    Liu, Lipeng
    Xiao, Chengjian
    Xiao, Ying
    Ding, Jinquan
    Zhang, Qungui
    Guo, Hailiang
    FRONTIERS IN ONCOLOGY, 2024, 14