The Validity and Usability of Markerless Motion Capture and Inertial Measurement Units for Quantifying Dynamic Movements

被引:0
作者
Edwards, Nathan a. [1 ,2 ]
Caccese, Jaclyn b. [1 ,2 ]
Tracy, Ryan e. [2 ]
Hagen, Joshua [1 ,2 ,3 ]
Quatman-yates, Catherine c. [2 ]
Onate, James [1 ,2 ]
机构
[1] Ohio State Univ, Human Performance Collaborat, Columbus, OH USA
[2] Ohio State Univ, Sch Hlth & Rehabil Sci, Columbus, OH USA
[3] Ohio State Univ, Integrated Syst Engn, Columbus, OH USA
关键词
BIOMECHANICS; KINEMATICS; MOTION ANALYSIS; MOVEMENT ASSESSMENT; WEARABLE SENSORS; JOINT COORDINATE SYSTEM; ISB RECOMMENDATION; CENTER LOCATION; LOWER-EXTREMITY; GAIT; HIP; RELIABILITY; KNEE; DEFINITIONS; PERFORMANCE;
D O I
10.1249/MSS.0000000000003579
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
PurposeMotion capture technology is quickly evolving, providing researchers, clinicians, and coaches with more access to biomechanics data. Markerless motion capture and inertial measurement units (IMUs) are continually developing biomechanics tools that need validation for dynamic movements before widespread use in applied settings. This study evaluated the validity of a markerless motion capture, IMU, and red, green, blue, and depth (RGBD) camera system as compared with marker-based motion capture during countermovement jumps, overhead squats, lunges, and runs with cuts.MethodsThirty adults were recruited for this study (sex: 18 females, 12 males; age: 25.4 +/- 8.6 yrs; height: 1.71 +/- 0.08 m; weight: 71.6 +/- 11.5 kg). Data were collected simultaneously with four motion capture technologies (i.e., Vicon, marker-based; Theia/Optitrack, markerless; APDM Opals, IMUs; and Vald HumanTrak, RGBD camera). System validity for lower and upper body joint angles was evaluated using bias, root mean squared error (RMSE), precision, maximum absolute error, and intraclass correlation coefficients. System usability was descriptively analyzed.ResultsOverall, markerless motion capture had the highest validity (sagittal plane RMSE: 3.20 degrees-15.66 degrees; frontal plane RMSE: 2.12 degrees-9.14 degrees; transverse plane RMSE: 3.160 degrees-56.61 degrees), followed by the IMU system (sagittal plane RMSE: 8.11 degrees-28.37 degrees; frontal plane RMSE: 3.26 degrees-16.98 degrees; transverse plane RMSE: 5.08 degrees-116.75 degrees), and lastly the RGBD system (sagittal plane bias: 0.55 degrees-129.48 degrees; frontal plane bias: 1.35 degrees-52.06 degrees).ConclusionsMarkerless motion capture and IMUs have moderate validity for joint kinematics, whereas the RGBD system did not have adequate validity. Markerless systems have lower data processing time, require moderate technical expertise, but have high data storage size. IMUs are easier to use, can collect data in any location, but require participant set-up. Overall, individuals using motion capture should consider the specific movements, testing locations, and technical expertise available before selecting a system.
引用
收藏
页码:641 / 655
页数:15
相关论文
共 50 条
  • [21] Concurrent validity of inertial measurement units in range of motion measurements of upper extremity: A systematic review and meta-analysis
    Li, Jinfeng
    Qiu, Fanji
    Gan, Liaoyan
    Chou, Li-Shan
    WEARABLE TECHNOLOGIES, 2024, 5
  • [22] Using inertial measurement units for quantifying the most intense jumping movements occurring in professional male volleyball players
    Lima, Ricardo Franco
    Silva, Ana Filipa
    Matos, Sergio
    Castro, Henrique de Oliveira
    Rebelo, Andre
    Clemente, Filipe Manuel
    Nobari, Hadi
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [23] Validity of an inertial measurement unit to assess pelvic orientation angles during gait, sit-stand transfers and step-up transfers: Comparison with an optoelectronic motion capture system
    Bolink, S. A. A. N.
    Naisas, H.
    Senden, R.
    Essers, H.
    Heyligers, I. C.
    Meijer, K.
    Grimm, B.
    MEDICAL ENGINEERING & PHYSICS, 2016, 38 (03) : 225 - 231
  • [24] Concurrent validity and test reliability of the deep learning markerless motion capture system during the overhead squat
    Bae, Kyungun
    Lee, Seyun
    Bak, Se-Young
    Kim, Hyo Sang
    Ha, Yuncheol
    You, Joshua H.
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [25] Validity of the Perception Neuron inertial motion capture system for upper body motion analysis
    Sers, Ryan
    Forrester, Steph
    Moss, Esther
    Ward, Stephen
    Ma, Jianjia
    Zecca, Massimiliano
    MEASUREMENT, 2020, 149
  • [26] Proposal for Post Hoc Quality Control in Instrumented Motion Analysis Using Markerless Motion Capture: Development and Usability Study
    Roehling, Hanna Marie
    Althoff, Patrik
    Arsenova, Radina
    Drebinger, Daniel
    Gigengack, Norman
    Chorschew, Anna
    Kroneberg, Daniel
    Roennefarth, Maria
    Ellermeyer, Tobias
    Rosenkranz, Sina Catherine
    Heesen, Christoph
    Behnia, Behnoush
    Hirano, Shigeki
    Kuwabara, Satoshi
    Paul, Friedemann
    Brandt, Alexander Ulrich
    Schmitz-Huebsch, Tanja
    JMIR HUMAN FACTORS, 2022, 9 (02):
  • [27] The Effect of Footwear, Running Speed, and Location on the Validity of Two Commercially Available Inertial Measurement Units During Running
    Napier, Christopher
    Willy, Richard W.
    Hannigan, Brett C.
    McCann, Ryan
    Menon, Carlo
    FRONTIERS IN SPORTS AND ACTIVE LIVING, 2021, 3
  • [28] Validity and reliability of inertial measurement units for gait assessment within a post stroke population
    Desai, Radhika
    Martelli, Dario
    Alomar, Jehan A.
    Agrawal, Sunil
    Quinn, Lori
    Bishop, Lauri
    TOPICS IN STROKE REHABILITATION, 2024, 31 (03) : 235 - 243
  • [29] Reliability of motion phase identification for long-track speed skating using inertial measurement units
    Iizuka, Tomoki
    Tomita, Yosuke
    PEERJ, 2024, 12
  • [30] Kinematics and temporospatial parameters during gait from inertial motion capture in adults with and without HIV: a validity and reliability study
    Berner, Karina
    Cockcroft, John
    Louw, Quinette
    BIOMEDICAL ENGINEERING ONLINE, 2020, 19 (01)