共 50 条
Early Results of Preserflo MicroShunt for Primary Open Angle Glaucoma in White Patients
被引:0
作者:
Pillunat, Karin R.
[1
]
Herber, Robert
[1
]
Jamke, Melanie
[1
]
Jasper, Carolin S.
[1
]
Haase, Maike A.
[1
]
Manseck, Anna S.
[1
]
Pillunat, Lutz E.
[1
]
机构:
[1] Tech Univ, Med Fac Carl Gustav Carus, Dept Ophthalmol, Fetscherstr 74, D-01307 Dresden, Germany
关键词:
Preserflo MicroShunt;
primary open angle glaucoma;
high pressure glaucoma;
normal pressure glaucoma;
normal tension glaucoma;
24-hour IOP;
peak diurnal IOP;
diurnal IOP fluctuation;
NORMAL-TENSION GLAUCOMA;
INTRAOCULAR-PRESSURE;
MEDICAL THERAPY;
MITOMYCIN-C;
TRABECULECTOMY;
PROGRESSION;
OUTCOMES;
REDUCTION;
D O I:
10.1097/IJG.0000000000002509
中图分类号:
R77 [眼科学];
学科分类号:
100212 ;
摘要:
Pr & eacute;cis:The Preserflo MicroShunt effectively lowered intraocular pressure in primary high and normal pressure open angle glaucoma.Purpose:To evaluate the efficacy and safety of the Preserflo MicroShunt in patients with primary open angle glaucoma (POAG) and the 2 variants high (HPG) and normal pressure glaucoma (NPG) after 1 year.Methods:Single-center prospective interventional case series consecutively including eyes of White/European patients with POAG, who received the Preserflo MicroShunt as a primary and standalone glaucoma intervention. Primary outcome measures: change in mean 24-hour IOP (mdIOP, mean of 6 measurements), peak IOP, IOP fluctuations, antiglaucoma medications, and success rates. Secondary outcome measures include visual acuity, visual fields, complications, surgical interventions, and adverse events.Results:Forty-two eyes of 42 patients with POAG, 29 in the HPG and 13 in the NPG group, were analyzed after 1-year follow-ups. Median [Q25, Q75] medicated mdIOP (mm Hg) dropped by 30% from 16.5 [13.7-27.3] to 12.8 [10.2-14.5] in the HPG and by 40% from 14.3 [13.3-16.0] to 9.5 [8.3-11.1] in the NPG group, with a median postoperative medication use of 0 [0-0] in both groups. At 1 year, 92.5% of eyes were medication-free versus 0% preoperatively. The reduction of mdIOP (P=1.0), peak IOP (P=0.932), IOP fluctuations (P=0.142), and the rate of interventions (P=0.298) were not statistically significantly different between the HPG and NPG group. None of the patients experienced severe adverse events or loss of vision.Conclusions:Effective and safe intraocular pressure lowering was observed 1 year following MicroShunt implantation for primary HPG and NPG in White patients of European descent.
引用
收藏
页码:103 / 113
页数:11
相关论文
共 50 条