Does Root Canal Shaping Effect the Accuracy of Electronic Apex Locators in Curved and Straight Root Canals?

被引:0
作者
Tekinarslan, Dide [1 ]
Erkal, Damla [1 ]
Ercan, Esen [1 ]
Koc, Simay [1 ]
Er, Kursat [1 ]
机构
[1] Akdeniz Univ, Fac Dent, Dept Endodont, Antalya, Turkiye
来源
CLINICAL AND EXPERIMENTAL HEALTH SCIENCES | 2024年 / 14卷 / 03期
关键词
Working length; root canal preparation; curvature; straight canal; WORKING LENGTH; ABILITY; INSTRUMENTATION; FREQUENCY;
D O I
10.33808/clinexphealthsci.1354100
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective: To assess the influence of root canal preparation (RCP) on the precision of electronic apex locators (EALs) in both straight and curved root canals. Methods: The experimental setup included forty-two extracted human mandibular molars featuring both straight distal canals (0-10 degrees) and curved mesial root canals (30-50 degrees). Initial working length (AWL1) measurements were conducted under a stereomicroscope at X15 magnification prior to root canal preparation (RCP). Subsequently, electronic working length (EWL1) was determined using two different electronic apex locators (EALs) - Propex-Pixi and EndoRadar. RCP was carried out with ProTaper Ultimate F1, F2 files in mesial canals, and F1, F2, F3 files in distal straight root canals. The RCP procedure involved the implementation of a standard irrigation protocol along with the use of a sonic device for activation. Following RCP, measurements were repeated under a stereomicroscope and documented as AWL2. EWL measurements were also repeated and recorded as EWL2 after the preparation. The variation was calculated by subtracting AWL from EWL for each tooth (EWL1-AWL1 and EWL2-AWL2). Statistical analysis employed Paired Sample t-test and Wilcoxon tests. Results: There was no statistically significant difference observed in the accuracy of Propex-Pixi and EndoRadar Pro before and after root canal preparation for both straight and curved canals. Conclusion: Root canal preparation did not alter the accuracy of the electronic apex locators (EALs) used in this study, whether applied to curved or straight root canals.
引用
收藏
页码:727 / 732
页数:6
相关论文
共 39 条
  • [1] SHAPING OF SIMULATED ROOT CANALS IN RESIN BLOCKS USING THE STEP-BACK TECHNIQUE WITH K-FILES MANIPULATED IN A SIMPLE IN OUT FILING MOTION
    ALODEH, MHA
    DOLLER, R
    DUMMER, PMH
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 1989, 22 (03) : 107 - 117
  • [2] Combination of apex locator and endodontic motor for continuous length control during root canal treatment
    Altenburger, M. J.
    Cenik, Y.
    Schirrmeister, J. F.
    Wrbas, K-T.
    Hellwig, E.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2009, 42 (04) : 368 - 374
  • [3] Effect of Canal Length and Curvature on Working Length Alteration with WaveOne Reciprocating Files
    Berutti, Elio
    Chiandussi, Giorgio
    Paolino, Davide Salvatore
    Scotti, Nicola
    Cantatore, Giuseppe
    Castellucci, Arnaldo
    Pasqualini, Damiano
    [J]. JOURNAL OF ENDODONTICS, 2011, 37 (12) : 1687 - 1690
  • [4] THE INFLUENCE OF DIFFERENT ROOT-CANAL INSTRUMENTS ON ROOT-CANAL PREPARATION - AN INVITRO STUDY
    BRISENO, BM
    SONNABEND, E
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 1991, 24 (01) : 15 - 23
  • [5] De Moor RJG, 1999, ENDOD DENT TRAUMATOL, V15, P77
  • [6] The ability of Root ZX apex locator to reduce the frequency of overestimated radiographic working length
    ElAyouti, A
    Weiger, R
    Löst, C
    [J]. JOURNAL OF ENDODONTICS, 2002, 28 (02) : 116 - 119
  • [7] Frequency of overinstrumentation with an acceptable radiographic working length
    ElAyouti, A
    Weiger, R
    Löst, C
    [J]. JOURNAL OF ENDODONTICS, 2001, 27 (01) : 49 - 52
  • [8] Gocer PA, 2023, Int Dent Res, V13, P20, DOI [10.5577/idr.2023.vol13.s1.3, DOI 10.5577/IDR.2023.VOL13.S1.3]
  • [9] In vitro evaluation of the ability of three apex locators to determine the working length during retreatment
    Goldberg, F
    Marroquín, BB
    Frajlich, S
    Dreyer, C
    [J]. JOURNAL OF ENDODONTICS, 2005, 31 (09) : 676 - 678
  • [10] Electronic apex locators
    Gordon, MPJ
    Chandler, NP
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2004, 37 (07) : 425 - 437