Enhancing Patient-specific Quality Assurance in Carbon-ion Radiation Therapy: Recalculating Delivered Dose Distribution Using Log Data

被引:0
作者
Yun, Yongdo [1 ]
Han, Min cheol [1 ]
Kim, Changhwan [1 ]
Hong, Chae-Seon [1 ]
Kim, Dong wook [1 ]
Lee, Ho [1 ]
Kim, Hojin [1 ]
Han, Soorim [1 ]
Souda, Hikaru [2 ]
Lee, Sung hyun [3 ]
Miyasaka, Yuya [2 ]
Iwai, Takeo [2 ]
Kim, Jin sung [1 ,4 ]
机构
[1] Yonsei Univ, Coll Med, Heavy Ion Therapy Res Inst, Dept Radiat Oncol,Yonsei Canc Ctr, Seoul 03722, South Korea
[2] Yamagata Univ, Grad Sch Med Sci, Dept Heavy Particle Med Sci, Yamagata, Japan
[3] Seoul Natl Univ, Coll Med, Dept Radiat Oncol, Seoul, South Korea
[4] Oncosoft Inc, Seoul, South Korea
来源
IN VIVO | 2025年 / 39卷 / 02期
关键词
Carbon-ion radiation therapy; log data; patient-specific quality assurance; treatment planning system; biological dose distribution;
D O I
10.21873/invivo.13913
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background/Aim: Log data from radiation treatment machines can play a crucial role in quality assurance by enabling the recalculation of the delivered dose distribution and identification of deviations in treatment delivery. This article proposes a novel method for recalculating the delivered dose distribution in carbon-ion radiation therapy using log data. Materials and Methods: The proposed approach leverages existing functionality in commercial treatment planning systems, thus eliminating the need for specialized in-house software for dose calculation and evaluation. The performed tests entail data generation from actual log files using the Digital Imaging and Communications in Medicine standard, biological dose calculations, and gamma evaluations. Results: The log-based approach demonstrated notable advantages, including improved time efficiency and the ability to calculate three-dimensional biological doses. By recalculating the delivered dose distributions, our method improves quality assurance accuracy in carbon-ion radiation therapy. It complements conventional measurement-based patient- specific quality assurance methods, serving as a valuable addition to the arsenal of tools available for treatment evaluation. Conclusion: We believe that our method has the potential to enhance the efficacy of patient-specific quality assurance and contribute significantly to the advancement of carbon-ion radiation therapy, thereby reinforcing the ongoing evolution of particle therapy.
引用
收藏
页码:1086 / 1093
页数:8
相关论文
共 23 条
[1]  
[Anonymous], About us
[2]  
Chen Z, 2022, Radiat Med Prot, V3, P123, DOI [10.1016/j.radmp.2022.06.002, DOI 10.1016/J.RADMP.2022.06.002]
[3]   Development and validation of an automatic commissioning tool for the Monte Carlo dose engine in myQA iON [J].
Cohilis, M. ;
Hong, L. ;
Janssens, G. ;
Rossomme, S. ;
Sterpin, E. ;
Lee, J. A. ;
Souris, K. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 95 :1-8
[4]   Implementation of automated personalised breast radiotherapy planning techniques with scripting in Raystation [J].
Gleeson, Ian ;
Bolger, Niall ;
Chun, Harmony ;
Hutchinson, Katie ;
Klodowska, Magdalena ;
Mehrer, Jennifer ;
Toomey, Marian .
BRITISH JOURNAL OF RADIOLOGY, 2023, 96 (1144)
[5]  
Han Eun Young, 2019, Med Dosim, V44, pe44, DOI 10.1016/j.meddos.2018.12.006
[6]   Treatment planning for a scanned carbon beam with a modified microdosimetric kinetic model [J].
Inaniwa, Taku ;
Furukawa, Takuji ;
Kase, Yuki ;
Matsufuji, Naruhiro ;
Toshito, Toshiyuki ;
Matsumoto, Yoshitaka ;
Furusawa, Yoshiya ;
Noda, Koji .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (22) :6721-6737
[7]   Carbon ion radiotherapy in Japan: an assessment of 20 years of clinical experience [J].
Kamada, Tadashi ;
Tsujii, Hirohiko ;
Blakely, Eleanor A. ;
Debus, Juergen ;
De Neve, Wilfried ;
Durante, Marco ;
Jaekel, Oliver ;
Mayer, Ramona ;
Orecchia, Roberto ;
Poetter, Richard ;
Vatnitsky, Stanislav ;
Chu, William T. .
LANCET ONCOLOGY, 2015, 16 (02) :E93-E100
[8]   Commissioning and clinical implementation of Mobius3D and MobiusFX: Experience on multiple linear accelerators [J].
Kim, Jihun ;
Han, Min Cheol ;
Park, Kwangwoo ;
Chang, Kyung Hwan ;
Kim, Dong Wook ;
Hong, Chae-Seon ;
Kim, Jin Sung .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 80 :1-9
[9]   In vivo proton range verification: a review [J].
Knopf, Antje-Christin ;
Lomax, Antony .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (15) :131-160
[10]   A technique for the quantitative evaluation of dose distributions [J].
Low, DA ;
Harms, WB ;
Mutic, S ;
Purdy, JA .
MEDICAL PHYSICS, 1998, 25 (05) :656-661