Experimental study on spatiotemporal variation patterns of thermal environment in the large-span insulated greenhouse

被引:0
|
作者
Li, He [1 ]
Zong, Chengji [1 ]
Lu, Jiarui [2 ]
Zhao, Shumei [1 ,3 ]
Yang, Dongyan [4 ]
Song, Weitang [1 ,3 ]
机构
[1] China Agr Univ, Coll Water Resources & Civil Engn, Beijing 100083, Peoples R China
[2] Wenzhou Vocat Coll Sci & Technol, Wenzhou 325014, Peoples R China
[3] Minist Agr & Rural Affairs, Key Lab Agr Engn Struct & Environm, Beijing 100083, Peoples R China
[4] Ningxia Acad Agr & Forestry Sci, Inst Hort Res, Yinchuan 750002, Peoples R China
基金
中国国家自然科学基金;
关键词
Greenhouse microclimate; Large-span plastic greenhouse; Low enclosure wall; Aluminum foil diffuse film; Thermal blanket; Energy saving; Uniformity; SOLAR GREENHOUSES; PERFORMANCE; DESIGN; ENERGY; LIGHT;
D O I
10.1016/j.applthermaleng.2025.125530
中图分类号
O414.1 [热力学];
学科分类号
摘要
Large-span plastic greenhouses face serious challenges of insufficient insulation performance and uneven thermal environment distribution, which would weaken the heat storage and release performance of active/passive environmental control systems. The research problem is thus the spatiotemporal characteristics of large-span externally insulated greenhouses yet to be quantified and energy-saving strategies for facility retrofitting still need to be addressed. The objective of this study is to analyze the greenhouse microclimate under the different insulation schemes, weather conditions and ventilation managements. The novelty of the work is that we introduce a low enclosure wall positioned at the bottom edge of transparent roofs to reduce the greenhouse heating load. Moreover, the aluminum foil diffusion film applied to the wall surface further improves the photothermal utilization. Main results of this experimental study are that the horizontal microclimate heterogeneity is primarily affected by the fixed insulation projection and outside temperature, and low enclosure walls mitigates the difference in energy demand between the east and west cultivation zones. The construction of low enclosure walls effectively elevates the average night-time temperature by 1.4-3.3 degrees C, while attaching aluminum foil diffusion film can again raise it again by 1-2 degrees C. The incorporation of passive thermal storage media is useless for low enclosure walls, since the intercepted radiation at the wall surface accounts for only 12.3 % of the cumulative intensity of solar radiation. For the renovated greenhouse structure, we assessed the dehumidification and cooling effects of different ventilation scenarios. The partitioned operation strategy for east-west external thermal blankets was specified to avoid condensation heat loss.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Experimental study on lead extrusion damper and its earthquake mitigation effects for large-span reticulated shell
    Yang, M. F.
    Xu, Z. D.
    Zhang, X. C.
    STEEL AND COMPOSITE STRUCTURES, 2015, 18 (02): : 481 - 496
  • [32] Analysis and Experimental Study on the Stability of Large-Span Caverns' Surrounding Rock Based on the Progressive Collapse Mechanism
    Chen, Huanxia
    Fan, Junqi
    Xu, Jingmao
    APPLIED SCIENCES-BASEL, 2024, 14 (13):
  • [33] Experimental Study on Seismic Response of a Large-Span and Column-Free Subway Station in Composite Strata
    Liu, Tingjin
    Zheng, Siyuan
    Tang, Xinwei
    Xu, Weixing
    SHOCK AND VIBRATION, 2019, 2019
  • [34] Study on stability in sliding of bearings supporting large-span steel roofs
    Yamashita T.
    Wada N.
    Journal of Structural and Construction Engineering, 2019, 84 (763): : 1251 - 1258
  • [35] Study on the Parameter Vibration of the Large-Span Cable-Stayed Bridges
    Li Feng-chen
    Tian Shi-zhu
    Li Yan-jun
    Wang Jin
    PROCEEDINGS OF THE 2009 SIXTH INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY: NEW GENERATIONS, VOLS 1-3, 2009, : 1701 - 1704
  • [36] Study on the Factory Prefabrication Technology of Large-span Bridge's Pier
    Wu Qihe
    Qiu Zhengzhong
    Niu Zhao
    ADVANCES IN CIVIL AND STRUCTURAL ENGINEERING III, PTS 1-4, 2014, 501-504 : 1413 - 1417
  • [37] Study on Bolt Support Technology for Large-Span Rectangular Coal Roadway
    Li, Jinhua
    ADVANCES IN CIVIL ENGINEERING, PTS 1-4, 2011, 90-93 : 271 - 276
  • [38] Study on foundation slope stability of large-span high tower bridge
    School of Civil Engineering, Southwest Jiaotong University, Chengdu 610031, China
    不详
    Yanshilixue Yu Gongcheng Xuebao, 2007, SUPPL. 1 (3177-3182):
  • [39] Study on wind tunnel tests for large-span flat roof structures
    Lu, Feng
    Lou, Wenjuan
    Sun, Bingnan
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2001, 22 (06):
  • [40] Experimental study on reducing wind suction of large-span sguare flat roof using passive vortex generators
    Zhang H.
    Liu T.
    Zhou L.
    Zhongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Central South University (Science and Technology), 2023, 54 (05): : 1839 - 1850