Iterative clustering material decomposition aided by empirical spectral correction for photon counting detectors in micro-CT

被引:0
|
作者
Luna, J. Carlos Rodriguez [1 ]
Das, Mini [1 ]
机构
[1] Univ Houston, Dept Phys, Houston, TX 77004 USA
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
photon counting detectors; signal-to-thickness calibration; material decomposition; spectral correction; micro-computed tomography; soft tissue classification; clustering analysis; COMPUTED-TOMOGRAPHY; PHASE RETRIEVAL; MODEL;
D O I
10.1117/1.JMI.11.S1.S12810
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Photon counting detectors offer promising advancements in computed tomography (CT) imaging by enabling the quantification and three-dimensional imaging of contrast agents and tissue types through simultaneous multi-energy projections from broad X-ray spectra. However, the accuracy of these decomposition methods hinges on precise composite spectral attenuation values that one must reconstruct from spectral micro-CT. Errors in such estimations could be due to effects such as beam hardening, object scatter, or detector sensor-related spectral distortions such as fluorescence. Even if accurate spectral correction is done, multi-material separation within a volume remains a challenge. Increasing the number of energy bins in material decomposition problems often comes with a significant noise penalty but with minimal decomposition benefits. Approach We begin with an empirical spectral correction method executed in the tomographic domain that accounts for distortions in estimated spectral attenuation for each voxel. This is followed by our proposed iterative clustering material decomposition (ICMD) where clustering of voxels is used to reduce the number of basis materials to be resolved for each cluster. Using a larger number of energy bins for the clustering step shows distinct advantages in excellent classification to a larger number of clusters with accurate cluster centers when compared with the National Institute of Standards and Technology attenuation values. The decomposition step is applied to each cluster separately where each cluster has fewer basis materials compared with the entire volume. This is shown to reduce the need for the number of energy bins required in each decomposition step for the clusters. This approach significantly increases the total number of materials that can be decomposed within the volume with high accuracy and with excellent noise properties. Results Utilizing a (cadmium telluride 1-mm-thick sensor) Medipix detector with a 55-mu m pitch, we demonstrate the quantitatively accurate decomposition of several materials in a phantom study, where the sample includes mixtures of soft materials such as water and poly-methyl methacrylate along with contrast-enhancing materials. We show improved accuracy and lower noise when all five energy bins were used to yield effective classification of voxels into multiple accurate fundamental clusters which was followed by the decomposition step applied to each cluster using just two energy bins. We also show an example of biological sample imaging and separating three distinct types of tissue in mice: muscle, fat, and bone. Our experimental results show that the combination of effective and practical spectral correction and high-dimensional data clustering enhances decomposition accuracy and reduces noise in micro-CT. Conclusions This ICMD allows for quantitative separation of multiple materials including mixtures and also effectively separates multi-contrast agents.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] Basis material decomposition in spectral CT using a semi-empirical, polychromatic adaption of the Beer-Lambert model
    Ehn, S.
    Sellerer, T.
    Mechlem, K.
    Fehringer, A.
    Epple, M.
    Herzen, J.
    Pfeiffer, F.
    Noel, P. B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (01) : N1 - N17
  • [42] Image-based spectral distortion correction for photon-counting x-ray detectors
    Ding, Huanjun
    Molloi, Sabee
    MEDICAL PHYSICS, 2012, 39 (04) : 1864 - 1876
  • [43] A neural network-based method for spectral distortion correction in photon counting x-ray CT
    Touch, Mengheng
    Clark, Darin P.
    Barber, William
    Badea, Cristian T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (16) : 6132 - 6153
  • [44] A unified statistical framework for material decomposition using multienergy photon counting x-ray detectors
    Choi, Jiyoung
    Kang, Dong-Goo
    Kang, Sunghoon
    Sung, Younghun
    Ye, Jong Chul
    MEDICAL PHYSICS, 2013, 40 (09)
  • [45] Effects of image denoising on quantitative material decomposition in photon-counting spectral computed tomography
    Evans, Connor J.
    Li, Mengzhou
    Niu, Chuang
    Wang, Ge
    Roeder, Ryan K.
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [46] Theoretical Comparison of a Dual Energy System and Photon Counting Silicon Detector Used for Material Quantification in Spectral CT
    Yveborg, Moa
    Danielsson, Mats
    Bornefalk, Hans
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (03) : 796 - 806
  • [47] Ring-Artifact Correction With Total-Variation Regularization for Material Images in Photon-Counting CT
    Murata, Kazumi
    Ogawa, Koichi
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2021, 5 (04) : 568 - 577
  • [48] Image-based Material Decomposition with a General Volume Constraint for Photon-Counting CT
    Li, Zhoubo
    Leng, Shuai
    Yu, Lifeng
    Yu, Zhicong
    McCollough, Cynthia H.
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [49] Iterative material decomposition for spectral CT using self-supervised Noise2Noise prior
    Fang, Wei
    Wu, Dufan
    Kim, Kyungsang
    Kalra, Mannudeep K.
    Singh, Ramandeep
    Li, Liang
    Li, Quanzheng
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (15)
  • [50] Empirical correction decomposition method (ECDM): enhancing accuracy of quantitative measurement in spectral CT
    Wang, Chengmin
    Wang, Zhe
    Li, Mohan
    Liu, Yuedong
    Zhang, Xiaomei
    Wei, Cunfeng
    Wei, Long
    PHYSICS IN MEDICINE AND BIOLOGY, 2025, 70 (01)