Performance analysis and city applicability evaluation of a transcritical CO2 heat pump system integrated with expander-compressor unit subcooling for space heating

被引:2
作者
Lv, Dewei [1 ]
Ran, Deyong [1 ]
Yang, Qichao [1 ]
Zhang, Wenting [1 ]
Zhao, Yuanyang [1 ]
Liu, Guangbin [1 ]
Li, Liansheng [1 ]
机构
[1] Qingdao Univ Sci & Technol, Coll Electromech Engn, Qingdao 266100, Peoples R China
基金
中国国家自然科学基金;
关键词
Heat pump; Expander-compressor unit subcooling; Performance analysis; City applicability; Transcritical CO2; SUPERMARKET REFRIGERATION SYSTEM; THERMOELECTRIC SUBCOOLER; CYCLE; ENERGY; OPTIMIZATION; EJECTOR; EXERGY; SIMULATION;
D O I
10.1016/j.energy.2025.135293
中图分类号
O414.1 [热力学];
学科分类号
摘要
CO2 air source heat pump is a crucial and environmentally friendly technology for space heating. However, the low performance due to the larger throttling loss and the sharp deterioration at higher return water temperature is a challenge. To enhance its performance, a transcritical CO2 heat pump system integrated with expander- compressor unit (E-C) subcooling is proposed, which can achieve subcooling while reducing throttling loss. Mathematical model and heating season performance model considering the effect of the gas cooler pinch point are developed and evaluated for three Chinese cities using different heating terminals. The result demonstrates a 21.9 % coefficient of performance (COP) improvement compared to the basic system. It also outperforms conventional mechanical subcooling CO2 heat pump system. The E-C unit can significantly reduce the exergy destruction of the expansion valve and compressor. Under the return and supply water temperature of 40/75 degrees C, with the varying of ambient temperature, the exergy efficiency of E-C system is 72.8 %-74.5 % which is better than the basic system of 64.5 %-65.8 %. The heating terminal using floor-coil radiator has the largest COP improvement about 33 % among the three cities. In conclusion, the novel system effectively enhances the CO2 heat pump performance and provides a solution for its application.
引用
收藏
页数:15
相关论文
共 51 条
[1]   Comparative energy and exergy analysis of a subcritical cascade refrigeration system using low global warming potential refrigerants [J].
Aktemur, Cenker ;
Ozturk, Ilhan Tekin ;
Cimsit, Canan .
APPLIED THERMAL ENGINEERING, 2021, 184
[2]  
[Anonymous], 2015, GB/T 51074-2015: code for urban heting supply planning
[3]  
[Anonymous], 2012, GB 50736-2012
[4]   Thermodynamic analyses on an ejector enhanced CO2 transcritical heat pump cycle with vapor-injection [J].
Bai, Tao ;
Yan, Gang ;
Yu, Jianlin .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 58 :22-34
[5]   Thermodynamics analysis of a modified dual-evaporator CO2 transcritical refrigeration cycle with two-stage ejector [J].
Bai, Tao ;
Yan, Gang ;
Yu, Jianlin .
ENERGY, 2015, 84 :325-335
[6]   Optimal heat rejection pressure of CO2 heat pump water heaters based on pinch point analysis [J].
Chen, Yun-Guang .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 106 :592-603
[7]   Pinch point analysis and design considerations of CO2 gas cooler for heat pump water heaters [J].
Chen, Yun-Guang .
INTERNATIONAL JOURNAL OF REFRIGERATION, 2016, 69 :136-146
[8]   New scenario of CO2 heat pump for space heating: Automatic mode switch between modified transcritical and cascade cycle in one system [J].
Cheng, Jia-Hao ;
He, Yu-Jia ;
Zhang, Chun-Lu .
APPLIED THERMAL ENGINEERING, 2021, 191
[9]   Pinch point variation in the gas cooler of the CO2 heat pump water heater: An experimental and simulation comparative study [J].
Cui, Qi ;
Gao, Enyuan ;
Wei, Dianhang ;
Qi, Pengcheng ;
Zhang, Xiaosong .
THERMAL SCIENCE AND ENGINEERING PROGRESS, 2023, 43
[10]   Exergy, carbon footprint and cost lifecycle evaluation of cascade mechanical subcooling CO2 commercial refrigeration system in China [J].
Dai, Baomin ;
Cao, Yu ;
Zhou, Xuan ;
Liu, Shengchun ;
Fu, Rao ;
Li, Cenxi ;
Wang, Dabiao .
JOURNAL OF CLEANER PRODUCTION, 2024, 434