Long-term clinical outcomes of isolated orbital floor fracture reconstruction using nonresorbable implants

被引:0
|
作者
Abd El Ghafar, Ayman E. [1 ]
Shawky, Nashaat [1 ]
Shaheen, Mahrous Hassan [2 ]
Aziz, Khalid Abdel [3 ]
Diab, Mostafa Mohamed [2 ,4 ]
机构
[1] Mansoura Univ, Ophthalm Ctr, Dept Ophthalmol, Mansoura, Egypt
[2] Fayoum Univ, Fac Med, Dept Ophthalmol, Al Fayoum, Egypt
[3] Beni Suef Univ, Fac Med, Dept Ophthalmol, Bani Suwayf, Egypt
[4] King Saud Univ, King Saud Univ Med City, Coll Med, Dept Ophthalmol, Riyadh, Saudi Arabia
关键词
Long-term outcomes; orbital floor fracture; polypropylene mesh; porous polyethylene sheet; titanium mesh; POROUS POLYETHYLENE CHANNEL; MESH; REPAIR; ADHERENCE; SECONDARY; DIPLOPIA; SURGERY;
D O I
10.4103/IJO.IJO_1100_24
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: There are no universally established guidelines for material selection in orbital wall fracture reconstruction. With an increasing preference for permanent implants, this study aimed to compare the long-term clinical outcomes of three different non-resorbable materials in reconstructing isolated orbital floor fractures. Design: A retrospective, interventional comparative study. Methods: The medical records of patients with unilateral pure orbital floor fractures who underwent orbital reconstruction using non-resorbable alloplastic implants at two tertiary referral centers between January 2017 to December 2021 were reviewed. Cases with non-pure orbital floor blowout fractures and/or <2 years of follow-up were excluded. Patients were separated into three groups according to the implant material type: porous polyethylene (PPE) sheet, polypropylene (PP) mesh, and titanium (Ti) mesh. These groups were then retrospectively analyzed for clinical outcomes, implant-related complications, and patient's satisfaction. Results: Sixty-six patients met the inclusion criteria. Twenty-four patients (36.36%) received PPE sheets, 20 patients (30.3%) had PP mesh, and 22 patients (33.33%) received Ti mesh. At the 6-month postoperative visit, nine patients (40.9%) in the Ti mesh group experienced postoperative diplopia compared to six patients (30.0%) in the PP group and one patient (4.2%) in the PPE group (P < 0.047). Following the initial 6-month postoperative period, the PP group had more frequent postoperative enophthalmos compared to the other 2 groups. The total ocular motility restriction score was significantly lower in the Ti mesh group compared to the other 2 groups at all follow-up visits. Patient's satisfaction was significantly higher in the PPE group (median = 10, IQR = 1) compared to the PP (median = 8.5, IQR = 3) and Ti groups (median = 8, IQR = 3), P < 0.001. Reoperation was needed in seven patients (31.8%) in the Ti group, two patients (10%) in the PP group, and none in the PPE group. Conclusions: The use of PPE orbital implants for the repair of isolated orbital floor fracture provides better long-term clinical outcomes compared to PP or Ti mesh and reduces the need for reoperation across all fracture sizes. Ti mesh has been associated with a higher frequency of unfavorable clinical outcomes and implant removal.
引用
收藏
页码:191 / 198
页数:9
相关论文
共 50 条
  • [1] Reconstruction of the orbital floor with polydioxanone: a long-term clinical survey of up to 12 years
    Beck-Broichsitter, Benedicta Elisabeth
    Acar, Carolin
    Kandzia, Christian
    Jochens, Arne
    Wiltfang, Joerg
    Becker, Stephan T.
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2015, 53 (08) : 736 - 740
  • [2] Pediatric Orbital Floor Reconstruction Using a Nonresorbable Polypropylene-Based Hernia Mesh: A Case Report
    Sharma, Gauri
    Shukla, Deepankar
    Bhola, Nitin D.
    Vishnani, Rozina
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (01)
  • [3] Delayed Orbital Floor Reconstruction Using Mirroring Technique and Patient-Specific Implants: Proof of Concept
    D'Alpaos, Diana
    Badiali, Giovanni
    Ceccariglia, Francesco
    Tarsitano, Achille
    JOURNAL OF PERSONALIZED MEDICINE, 2024, 14 (05):
  • [4] Long-term Effect of Individualized Titanium Mesh in Orbital Floor Reconstruction After Maxillectomy
    Sun, Qian
    Soh, Hui-Yuh
    Zhang, Wen-bo
    Yu, Yao
    Wang, Yang
    Mao, Chi
    Guo, Chuan-bin
    Yu, Guang-yan
    Peng, Xin
    LARYNGOSCOPE, 2021, 131 (10) : 2231 - 2237
  • [5] Reconstruction of Large Orbital Posterior Floor Wall Fracture Considering Orbital Floor Slope Using Endoscope
    Park, Jinhwan
    Huh, Jungah
    Lee, Joonsik
    Chang, Minwook
    Lee, Hwa
    Park, Minsoo
    Baek, Sehyun
    JOURNAL OF CRANIOFACIAL SURGERY, 2017, 28 (04) : 947 - 950
  • [6] Quantitative assessment of increase in orbital volume after orbital floor fracture reconstruction using a bioabsorbable implant
    Park, Hyun Young
    Kim, Tae Hyung
    Yoon, Jin Sook
    Ko, JaeSang
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 260 (09) : 3027 - 3036
  • [7] Broad Application of the Endoscope for Orbital Floor Reconstruction: Long-Term Follow-Up Results
    Cheong, Ee-Cherk
    Chen, Chien-Tzung
    Chen, Yu-Ray
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2010, 125 (03) : 969 - 978
  • [8] Matrixmidface Preformed Orbital Implants for Three-Dimensional Reconstruction of Orbital Floor and Medial Wall Fractures: A Prospective Clinical Study
    Chodankar, Neha Umakant
    Dhupar, Vikas
    Akkara, Francis
    Vijay, Vathsalya
    CRANIOMAXILLOFACIAL TRAUMA & RECONSTRUCTION, 2024, 17 (02) : 104 - 114
  • [9] Long-term follow-up of blowout fractures of the orbital floor reconstructed with a polyglactin 910/PDS implant
    Blake, F.
    Blessmann, M.
    Smeets, R.
    Friedrich, R.
    Schmelzle, R.
    Heiland, M.
    Eichhorn, W.
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2011, 37 (06) : 609 - 613
  • [10] Radiologic and Facial Morphologic Long-Term Results in Treatment of Orbital Floor Fracture With Flexible Absorbable Alloplastic Material
    Gerressen, Marcus
    Gillessen, Simone
    Riediger, Dieter
    Hoelzle, Frank
    Modabber, Ali
    Ghassemi, Alireza
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2012, 70 (10) : 2375 - 2385