Regularized origin ensemble with a beam prior for range verification in particle therapy with Compton-camera data

被引:0
作者
Kasprzak, Jona [1 ]
Roser, Jorge [1 ,2 ]
Werner, Julius [1 ]
Kohlhase, Nadja [1 ,3 ]
Bolke, Andreas [1 ,4 ]
Kaufmann, Lisa-Marie [1 ,5 ]
Rafecas, Magdalena [1 ]
机构
[1] Univ Lubeck, Inst Med Engn, Lubeck, Germany
[2] Univ Valencia, Inst Fis Corpuscular, Valencia, Spain
[3] Europa Radiochirurg Ctr Munchen, Munich, Germany
[4] Med Imaging Elect, Seth, Germany
[5] Stadtisches Klinikum Luneburg, Med Phys & Tech, Luneburg, Germany
关键词
origin ensemble; image reconstruction; compton camera; regularization; beam prior; particle therapy; Gibbs prior; GAMMA-RAY EMISSION; PROMPT-GAMMA; IMAGE-RECONSTRUCTION; PROTON THERAPY; FEASIBILITY; SIMULATION; TELESCOPE; SELECTION; PATIENT; SYSTEM;
D O I
10.1088/1361-6560/adbfd8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. In particle therapy (PT), several methods are being investigated to help reduce range margins and identify deviations from the original treatment plan, such as prompt-gamma imaging with Compton cameras (CC). To reconstruct the images, the Origin Ensemble (OE) algorithm is commonly used. In the context of PT, artifacts and strong noise often affect CC images. To improve the ability of OE to identify range shifts, and also to enhance image quality, we propose to regularize OE using beam a-priori knowledge (beam prior). Approach. We implemented the beam prior to OE using the class of Gibbs' distribution functions. For evaluation, Monte-Carlo simulations of centered and off-center beams with therapeutic energies impinging on a PMMA target were conducted in GATE. To introduce range shifts, air layers were introduced into the target. In addition, the effect of a bone layer, closer to a realistic scenario, was investigated. OE with the beam prior (BP-OE) and conventional OE (reference) were compared using the spill-over-ratio (SOR) as well as shifts in the distal falloff in projections using cubic splines with Chebyshev nodes. Main results. BP-OE improved the shift estimates by up to 11% compared to conventional OE for centered and up to 250% with off-centered beams. BP-OE decreased the image noise level, improving the SOR significantly by up to 96%. Significance. BP-OE applied to CC data can improve shift estimations compared to conventional OE. The developed Gibbs-based regularization framework also allows further prior functions to be included into OE, for instance, smoothing or edge-preserving priors. BP-OE could be extended to PET-based range verification or multiple-beam scenarios.
引用
收藏
页数:24
相关论文
共 95 条
  • [81] Ter Braak C. J. F., 1995, P29
  • [82] Monitoring the Bragg peak location of 73 MeV/u carbon ions by means of prompt γ-ray measurements
    Testa, E.
    Bajard, M.
    Chevallier, M.
    Dauvergne, D.
    Le Foulher, F.
    Freud, N.
    Letang, J. -M.
    Poizat, J. -C.
    Ray, C.
    Testa, M.
    [J]. APPLIED PHYSICS LETTERS, 2008, 93 (09)
  • [83] A Compton camera prototype for prompt gamma medical imaging
    Thirolf, P. G.
    Aldawood, S.
    Boehmer, M.
    Bortfeldt, J.
    Castelhano, I.
    Dedes, G.
    Fiedler, F.
    Gernhaeuser, R.
    Golnik, C.
    Helmbrecht, S.
    Hueso-Gonzalez, F.
    Kolff, H. V. D.
    Kormoll, T.
    Lang, C.
    Liprandi, S.
    Lutter, R.
    Marinsek, T.
    Maier, L.
    Pausch, G.
    Petzoldt, J.
    Roemer, K.
    Schaart, D.
    Parodi, K.
    [J]. 12TH INTERNATIONAL CONFERENCE ON NUCLEUS-NUCLEUS COLLISIONS 2015, 2016, 117
  • [84] Simultaneous in vivo imaging with PET and SPECT tracers using a Compton-PET hybrid camera
    Uenomachi, Mizuki
    Takahashi, Miwako
    Shimazoe, Kenji
    Takahashi, Hiroyuki
    Kamada, Kei
    Orita, Tadashi
    Ogane, Kenichiro
    Tsuji, Atsushi B.
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [85] Proton range verification through prompt gamma-ray spectroscopy
    Verburg, Joost M.
    Seco, Joao
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (23) : 7089 - 7106
  • [86] Simulation of prompt gamma-ray emission during proton radiotherapy
    Verburg, Joost M.
    Shih, Helen A.
    Seco, Joao
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (17) : 5459 - 5472
  • [87] An accurate probabilistic model with detector resolution and Doppler broadening correction in list-mode MLEM reconstruction for Compton camera
    Wu, Chuanpeng
    Zhang, Siyuan
    Li, Liang
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (12)
  • [88] Time-of-flight PET image reconstruction using origin ensembles
    Wuelker, Christian
    Sitek, Arkadiusz
    Prevrhal, Sven
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (05) : 1919 - 1944
  • [89] Yao Z., 2021, 2021 IEEE NUCL SCI S, P1, DOI [10.1109/NSS/MIC44867.2021.9875766, DOI 10.1109/NSS/MIC44867.2021.9875766]
  • [90] Dose reconstruction with Compton camera during proton therapy via subset-driven origin ensemble and double evolutionary algorithm
    Yao, Zhi-Yang
    Xiao, Yong-Shun
    Zhao, Ji-Zhong