Development and validation of a multiclass LC-MS/MS method for the analysis of cyanotoxins

被引:0
作者
Zamlynny, Lydia [1 ,2 ]
Morris, Hannah M. [1 ]
Giddings, Sabrina D. [2 ]
Kollatz, Johannes [3 ,4 ]
Niedermeyer, Timo H. J. [3 ]
Jamieson, Rob C. [1 ]
Beach, Daniel G. [1 ,2 ]
机构
[1] Dalhousie Univ, Dept Civil & Resource Engn, 6299 South St, Halifax, NS, Canada
[2] Natl Res Council Canada, Metrol Res Ctr, 1411 Oxford St, Halifax, NS B3H 3Z1, Canada
[3] Free Univ Berlin, Inst Pharm, Konigin Luise Str 24, D-14195 Berlin, Germany
[4] Leibniz Inst Plant Biochem, Dept Bioorgan Chem, Weinberg 3, D-6120 Halle, Saale, Germany
基金
加拿大自然科学与工程研究理事会;
关键词
Cyanobacteria; Microcystins; Cylindrospermopsins; Anatoxins; Aetokthonotoxin; LC-MS/MS; Multiclass analysis; Cyanotoxins; TANDEM MASS-SPECTROMETRY; TIME-OF-FLIGHT; FRESH-WATER; ANATOXIN-A; TOXINS; ALGAL; QUANTIFICATION; CYANOBACTERIA;
D O I
10.1007/s00216-025-05829-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Cyanobacteria are prokaryotic organisms that can form large monospecific blooms, which pose a risk to human and animal health as some species produce toxic secondary metabolites called cyanotoxins. Multiclass cyanotoxin analysis is challenging due to varying chemical and physical properties between classes, as well as potentially large numbers of analogues within each class. Incorporating anatoxins (ATXs) into multiclass methods can be particularly challenging due to their small molecular size, potential interferences, polarity, and a lack of chemical standards for most analogues. Here, we present the development of a multiclass LC-MS/MS method and a quantitative calibration solution for aetokthonotoxin (AETX), an emerging cyanotoxin linked to mass mortalities of bald eagles in the Eastern United States. The developed method is capable of detecting 17 microcystins (MCs), nodularin-R, three cylindrospermopsins (CYNs), AETX, and 17 ATXs, including recently tentatively identified 10-hydroxy analogues. Analytes were identified by retention time and product ion ratio matching with available standards. The method was evaluated with respect to limits of detection (LODs), linear range, accuracy, and precision using neat and matrix matched standards. LODs in wet cyanobacterial biofilms ranged from 0.14 ng/g for CYN to 2.8 ng/g for [Dha(7)]MC-LR with accuracies ranging from 65% for [Leu(1)]MC-LY to 116% for CYN. Finally, the method's application was demonstrated through analysis of cyanobacterial field samples, a dietary supplement matrix reference material, and passive sampler extracts to assess versatility within different matrices.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Development, validation and application of a LC-MS/MS method for quantification of 15 cannabinoids in food
    Christinat, Nicolas
    Savoy, Marie-Claude
    Mottier, Pascal
    [J]. FOOD CHEMISTRY, 2020, 318
  • [42] Bioanalytical method development and validation for quantification of amivantamab in rat plasma by LC-MS/MS
    Gaddey, Pridhvi Krishna
    Sundararajan, Raja
    [J]. FUTURE JOURNAL OF PHARMACEUTICAL SCIENCES, 2024, 10 (01)
  • [43] Development and Validation of New LC-MS/MS Method for the Determination of armodafinil in Human Plasma
    Ramesh, Devi
    Ramakrishna, Singirikonda
    Habibuddin, Mohammad
    [J]. CURRENT PHARMACEUTICAL ANALYSIS, 2012, 8 (03) : 295 - 305
  • [44] Method Development and Validation for Determination of Voglibose in Tablet Formulation Using LC-MS/MS
    Rajput, Mithlesh
    Dahiya, Meenakshi
    Kumari, Premlata
    Kalra, Kamini
    Aggarwal, Manjeet
    Khandal, R. K.
    [J]. E-JOURNAL OF CHEMISTRY, 2011, 8 (04) : 1770 - 1783
  • [45] Development and validation of an analytical method for pyrimisulfan determination in agricultural commodities by LC-MS/MS
    Do, Jung-Ah
    Lee, Mi-Young
    Cho, Yoon-Jae
    Kang, Iil-hyun
    Kwon, Kisung
    Oh, Jae-Ho
    [J]. ANALYTICAL SCIENCE AND TECHNOLOGY, 2013, 26 (02) : 154 - 163
  • [46] Development and validation of LC-MS/MS method for quantitative determination of (-)-securinine in mouse plasma
    Wabuyele, Simuli L.
    Wald, David
    Xu, Yan
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 960 : 19 - 26
  • [47] Development and validation of a simple, rapid and sensitive LC-MS/MS method for the measurement of urinary neurotransmitters and their metabolites
    Yan, Jingya
    Kuzhiumparambil, Unnikrishnan
    Bandodkar, Sushil
    Solowij, Nadia
    Fu, Shanlin
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (30) : 7191 - 7199
  • [48] Development and validation of a LC-MS/MS method for the quantification of the regioisomers of dihydroxybutylether in human plasma
    Yuan, Bo
    Li, Li
    Fu, Yao
    Jin, Yi
    Guo, Lixin
    Xu, Haiyan
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 911 : 27 - 33
  • [49] Development and validation of an LC-MS/MS method for the determination of six gestagens in kidney fats
    Rejtharova, Martina
    Rejthar, Libor
    [J]. FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2013, 30 (06): : 995 - 999
  • [50] Development and validation of an analytical method by LC-MS/MS for the quantification of estrogens in sewage sludge
    Gabet-Giraud, Virginie
    Miege, Cecile
    Herbreteau, Bernard
    Hernandez-Raquet, Guillermina
    Coquery, Marina
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (05) : 1841 - 1851