Development and validation of a multiclass LC-MS/MS method for the analysis of cyanotoxins

被引:0
|
作者
Zamlynny, Lydia [1 ,2 ]
Morris, Hannah M. [1 ]
Giddings, Sabrina D. [2 ]
Kollatz, Johannes [3 ,4 ]
Niedermeyer, Timo H. J. [3 ]
Jamieson, Rob C. [1 ]
Beach, Daniel G. [1 ,2 ]
机构
[1] Dalhousie Univ, Dept Civil & Resource Engn, 6299 South St, Halifax, NS, Canada
[2] Natl Res Council Canada, Metrol Res Ctr, 1411 Oxford St, Halifax, NS B3H 3Z1, Canada
[3] Free Univ Berlin, Inst Pharm, Konigin Luise Str 24, D-14195 Berlin, Germany
[4] Leibniz Inst Plant Biochem, Dept Bioorgan Chem, Weinberg 3, D-6120 Halle, Saale, Germany
基金
加拿大自然科学与工程研究理事会;
关键词
Cyanobacteria; Microcystins; Cylindrospermopsins; Anatoxins; Aetokthonotoxin; LC-MS/MS; Multiclass analysis; Cyanotoxins; TANDEM MASS-SPECTROMETRY; TIME-OF-FLIGHT; FRESH-WATER; ANATOXIN-A; TOXINS; ALGAL; QUANTIFICATION; CYANOBACTERIA;
D O I
10.1007/s00216-025-05829-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Cyanobacteria are prokaryotic organisms that can form large monospecific blooms, which pose a risk to human and animal health as some species produce toxic secondary metabolites called cyanotoxins. Multiclass cyanotoxin analysis is challenging due to varying chemical and physical properties between classes, as well as potentially large numbers of analogues within each class. Incorporating anatoxins (ATXs) into multiclass methods can be particularly challenging due to their small molecular size, potential interferences, polarity, and a lack of chemical standards for most analogues. Here, we present the development of a multiclass LC-MS/MS method and a quantitative calibration solution for aetokthonotoxin (AETX), an emerging cyanotoxin linked to mass mortalities of bald eagles in the Eastern United States. The developed method is capable of detecting 17 microcystins (MCs), nodularin-R, three cylindrospermopsins (CYNs), AETX, and 17 ATXs, including recently tentatively identified 10-hydroxy analogues. Analytes were identified by retention time and product ion ratio matching with available standards. The method was evaluated with respect to limits of detection (LODs), linear range, accuracy, and precision using neat and matrix matched standards. LODs in wet cyanobacterial biofilms ranged from 0.14 ng/g for CYN to 2.8 ng/g for [Dha(7)]MC-LR with accuracies ranging from 65% for [Leu(1)]MC-LY to 116% for CYN. Finally, the method's application was demonstrated through analysis of cyanobacterial field samples, a dietary supplement matrix reference material, and passive sampler extracts to assess versatility within different matrices.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] DEVELOPMENT AND VALIDATION OF A LC-MS/MS METHOD FOR THE QUANTITATIVE DETERMINATION OF TRAMADOL HYDROCHLORIDE
    Panainte, Alina Diana
    Popa, Viorica
    Agoroaei, Luminita
    Cimpoesu, Carmen Diana
    Sava, A.
    Paduraru, Larisa
    Bibire, Nela
    MEDICAL-SURGICAL JOURNAL-REVISTA MEDICO-CHIRURGICALA, 2023, 127 (01): : 122 - 132
  • [22] Development and Validation of LC-MS/MS Method for the Quantitation of Infliximab in Human Serum
    Peng, Xiaoyun
    Liu, Boning
    Li, Yantao
    Wang, Hui
    Chen, Xi
    Guo, Huaizu
    Guo, Qingcheng
    Xu, Jin
    Wang, Hao
    Zhang, Dapeng
    Dai, Jianxin
    Hou, Sheng
    Guo, Yajun
    CHROMATOGRAPHIA, 2015, 78 (7-8) : 521 - 531
  • [23] Method Development and Validation of Anabasine and Nornicotine in Human Plasma by LC-MS/MS
    Rajagopaludu, P.
    Saritha, N.
    Devanna, N.
    Srinivas, M.
    JOURNAL OF PHARMACEUTICAL RESEARCH INTERNATIONAL, 2021, 33 (17) : 7 - 17
  • [24] Development and clinical validation of an LC-MS/MS method for the quantification of pazopanib in DBS
    Verheijen, Remy B.
    Bins, Sander
    Thijssen, Bas
    Rosing, Hilde
    Nan, Lianda
    Schellens, Jan H. M.
    Mathijssen, Ron H. J.
    Lolkema, Martijn P.
    Beijnen, Jos H.
    Steeghs, Neeltje
    Huitema, Alwin D. R.
    BIOANALYSIS, 2016, 8 (02) : 123 - 134
  • [25] An LC-MS/MS Method Development and Validation for the Quantification of Abametapir in Plasma Samples
    Sankar, Palakollu D. S.
    Panigrahi, Naresh
    SEPARATION SCIENCE PLUS, 2025, 8 (01):
  • [26] Development and validation of a LC-MS/MS method for quantification of hetrombopag for pharmacokinetics study
    Chen, Tao
    Chen, Zhonghua
    Zhang, Suxing
    Zhang, Kezhi
    Wang, Laiyou
    SPRINGERPLUS, 2015, 4
  • [27] Development and validation of an easy multiresidue method for the determination of multiclass pesticide residues using GC-MS/MS and LC-MS/MS in olive oil and olives
    Anagnostopoulos, C.
    Miliadis, G. E.
    TALANTA, 2013, 112 : 1 - 10
  • [28] Development of LC-MS and LC-MS/MS Methods for Free Asparagine in Grains
    Chikasou, Masato
    Inohana, Syuichi
    Yokozeki, Toshiaki
    Tuchiya, Hitoshi
    Fujita, Kazuhiro
    FOOD HYGIENE AND SAFETY SCIENCE, 2018, 59 (05): : 248 - 256
  • [29] Development and validation of a sensitive and selective LC-MS/MS method for determination of tacrolimus in oral fluids
    Ghareeb, Mwlod
    Akhlaghi, Fatemeh
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1038 : 136 - 141
  • [30] LC-MS/MS Method Development and Validation for Determination of Favipiravir Pure and Tablet Dosage Forms
    Itigimath, Nandeesha
    Ashoka, Hadagali
    Yallur, Basappa C.
    Hadagali, Manjunatha Devagondanahalli
    TURKISH JOURNAL OF PHARMACEUTICAL SCIENCES, 2023, 20 (04) : 226 - 233