How Do Robotics and Navigation Facilitate Minimally Invasive Spine Surgery? A Case Series and Narrative Review

被引:0
作者
Quiceno, Esteban [1 ,2 ]
Soliman, Mohamed A. R. [1 ,2 ,3 ]
Khan, Asham [1 ,2 ]
Mullin, Jeffrey P. [1 ,2 ]
Pollina, John [1 ,2 ]
机构
[1] Univ Buffalo, Jacobs Sch Med & Biomed Sci, Dept Neurosurg, Buffalo, NY USA
[2] Buffalo Gen Med Ctr, Kaleida Hlth, Dept Neurosurg, Buffalo, NY USA
[3] Cairo Univ, Fac Med, Dept Neurosurg, Cairo, Egypt
关键词
Cost-effectiveness; Lateral lumbar interbody fusion; Minimally invasive surgery; Navigation; Robotic-assisted spine surgery; Oblique lateral interbody fusion; Transforaminal lumbar interbody fusion; LUMBAR INTERBODY FUSION; PEDICLE SCREW PLACEMENT; SINGLE-POSITION SURGERY; RADIATION-EXPOSURE; PRONE TRANSPSOAS; ACCURACY; INSERTION; GUIDANCE; DISEASE; PATIENT;
D O I
10.1227/neu.0000000000003352
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND OBJECTIVES:Image guidance has transformed minimally invasive spine surgery (MISS), allowing for safer procedures without excessive bony exposure and reducing radiation exposure for the surgical team. Robotic platforms have enhanced the benefits of navigation by providing high precision and accuracy. Here we describe a case series to demonstrate the accuracy and low complication rates of real-time image-guided robotic-assisted (RA) MISS at a tertiary referral center. In addition, we performed a narrative review on how robotics and navigation facilitate MISS.METHODS:A retrospective chart review was conducted to obtain data for patients who underwent RA lumbar fusions with real-time navigation for degenerative lumbar pathology between September 1, 2021, and January 1, 2024. The Mazor X Stealth Edition (Medtronic) robotic platform was used. The accuracy of screw placement was determined according to Gertzbein-Robbins classification. Intraoperative and postoperative complication rates up to 90 days were recorded. Intraoperative variables and length of stay were compared between open and percutaneous groups.RESULTS:A total of 247 patients underwent insertion of 1156 pedicle screws. The mean patient age was 61.1 +/- 11.5 years. The mean total operative time was 195.1 +/- 80.8 minutes. The mean operative time per screw was 4.2 +/- 1.4 minutes, with a mean of 4.6 +/- 1.4 screws per case. The mean fluoroscopy time per screw was 6.4 +/- 6.2 seconds. Eighty-five patients (34.4%) underwent open RA pedicle screw placement, and 162 (65.6%) underwent percutaneous RA pedicle screw placement. No differences in operative time, length of stay, fluoroscopy time, and surgical complications were found between groups. Intraoperatively, 2 patients (0.8%) experienced complications and 4 patients (1.6%) developed complications within 90 days. Screw placement accuracy was perfect in 1126 screws (97.4%) and clinically acceptable in 30 screws (2.6%). These results were consistent with those reported in the literature.CONCLUSION:Robotic platforms have further enhanced navigation benefits by providing high precision and accuracy, with low complication rates.
引用
收藏
页码:S84 / S93
页数:10
相关论文
共 71 条
[21]   Single-Position Surgery versus Lateral-Then-Prone-Position Circumferential Lumbar Interbody Fusion: A Systematic Literature Review [J].
Guiroy, Alfredo ;
Carazzo, Charles ;
Camino-Willhuber, Gaston ;
Gagliardi, Martin ;
Fernandes-Joaquim, Andrei ;
Cabrera, Juan Pablo ;
Menezes, Cristiano ;
Asghar, Jahangir .
WORLD NEUROSURGERY, 2021, 151 :E379-E386
[22]   Comparison of Outcomes between Robot-Assisted Minimally Invasive Transforaminal Lumbar Interbody Fusion and Oblique Lumbar Interbody Fusion in Single-Level Lumbar Spondylolisthesis [J].
Han, Xiao-guang ;
Tang, Guo-qing ;
Han, Xiao ;
Xing, Yong-gang ;
Zhang, Qi ;
He, Da ;
Tian, Wei .
ORTHOPAEDIC SURGERY, 2021, 13 (07) :2093-2101
[23]   The 6 T's of Minimally Invasive Spine Surgery [J].
Hartl, Roger .
GLOBAL SPINE JOURNAL, 2020, 10 :5S-7S
[24]   Single position L5-S1 lateral ALIF with simultaneous robotic posterior fixation is safe and improves regional alignment and lordosis distribution index [J].
Hernandez, Nicholas S. ;
Diaz-Aguilar, L. Daniel ;
Pham, Martin H. .
EUROPEAN SPINE JOURNAL, 2024, 33 (09) :3583-3592
[25]   Navigated robot-guided pedicle screws placed successfully in single-position lateral lumbar interbody fusion [J].
Huntsman, Kade T. ;
Riggleman, Jessica R. ;
Ahrendtsen, Leigh A. ;
Ledonio, Charles G. .
JOURNAL OF ROBOTIC SURGERY, 2020, 14 (04) :643-647
[26]   Reoperation Rates Following Instrumented Lumbar Spine Fusion [J].
Irmola, Tero Matti ;
Hakkinen, Arja ;
Jarvenpaa, Salme ;
Marttinen, Ilkka ;
Vihtonen, Kimmo ;
Neva, Marko .
SPINE, 2018, 43 (04) :295-301
[27]   Robotic-assisted spine surgery allows for increased pedicle screw sizes while still improving safety as indicated by elevated triggered electromyographic thresholds [J].
Kanaly, Charles W. ;
Backes, Danielle M. ;
Toossi, Nader ;
Bucklen, Brandon .
JOURNAL OF ROBOTIC SURGERY, 2023, 17 (03) :1007-1012
[28]  
Karami KJ, 2015, J SPINAL DISORD TECH, V28, pE133, DOI 10.1097/BSD.0000000000000178
[29]   CT-to-fluoroscopy registration versus scan-and-plan registration for robot-assisted insertion of lumbar pedicle screws [J].
Khan, Asham ;
Soliman, Mohamed A. R. ;
Lee, Nathan J. ;
Waqas, Muhammad ;
Lombardi, Joseph M. ;
Boddapati, Venkat ;
Levy, Lauren C. ;
Mao, Jennifer Z. ;
Park, Paul J. ;
Mathew, Justin ;
Lehman, Ronald A. ;
Mullin, Jeffrey P. ;
Pollina, John .
NEUROSURGICAL FOCUS, 2022, 52 (01)
[30]   Next-Generation Robotic Spine Surgery: First Report on Feasibility, Safety, and Learning Curve [J].
Khan, Asham ;
Meyers, Joshua E. ;
Siasios, Ioannis ;
Pollina, John .
OPERATIVE NEUROSURGERY, 2019, 17 (01) :61-68