Design and Implementation of a High-Sensitivity Inertial Cilium Combined Hydrophone for Low-Frequency Detection

被引:0
作者
Huang, Yuhao [1 ,2 ]
Zhang, Guojun [1 ,2 ]
Zhang, Wenqing [1 ,2 ]
Ren, Weirong [1 ,2 ]
Guo, Zimeng [1 ,2 ]
Zhang, Jie [1 ,2 ]
Geng, Yanan [1 ,2 ]
Zhang, Wendong [1 ,2 ]
机构
[1] North Univ China, Sch Instrument & Elect, Taiyuan 030051, Peoples R China
[2] North Univ China, State Key Lab Dynam Measurement Technol, Taiyuan 030051, Peoples R China
基金
中国国家自然科学基金;
关键词
Vectors; Vibrations; Micromechanical devices; Sensitivity; Accelerometers; Piezoresistance; Resonant frequency; Structural beams; Sensors; Acoustics; High sensitivity; low-frequency detection; microelectromechanical system (MEMS) piezoresistive accelerometer; PZT scalar hydrophone; resonant vector hydrophone;
D O I
10.1109/JSEN.2024.3503607
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Aiming at the insufficiency of hydrophones for high-sensitivity detection in the low-frequency domain, this article presents for the first time an inertial-type hydrophone encapsulating a microelectromechanical system (MEMS) stress-concentrated four-cantilever-beam piezoresistive accelerometer as a vector channel. At the same time, this inertial cilium combined hydrophone (ICCH) also integrates piezoelectric ceramic circular tubes as scalar channels. An inertial combined hydrophone package structure with an outer diameter of 63 mm combined with the theory of underwater sphere acoustic reception is designed. The chip of the ICCH vector channel is fabricated by the MEMS process, and the effective working frequency band is 10-630 Hz; the sensitivity in the X- and Y-directions are -175.1 dB@500 Hz -174.8 dB@500 Hz (0 dB =1 V/ mu Pa), respectively. Compared with the MEMS co-vibration combined hydrophone (CCH), the sensitivity is improved by 8.6 dB. The concave point depths are 44.1 and 43.5 dB, respectively, with good cosine directivity. The scalar channel sensitivity is -166.6 dB@500 Hz with omnidirectionality. The error of directional detection in the lake test experiment is less than 3 degrees. The above results show that the hydrophone can meet the need for precise localization and has a broad application prospect in low-frequency hydroacoustic detection.
引用
收藏
页码:2310 / 2320
页数:11
相关论文
共 28 条
  • [21] Theoretical research on the application of impedance calculation in the design of high-intensity low-frequency acoustic generator
    Zhang, Baoguo
    Dong, Mingrong
    Liang, Xubin
    Zhang, Min
    Zhao, Tianqing
    He, Bin
    Sun, Deyu
    JOURNAL OF LOW FREQUENCY NOISE VIBRATION AND ACTIVE CONTROL, 2024, 43 (02) : 906 - 919
  • [22] A Low Dark Leakage Current High-Sensitivity CMOS Image Sensor With STI-Less Shared Pixel Design
    Seo, Min-Woong
    Kawahito, Shoji
    Yasutomi, Keita
    Kagawa, Keiichiro
    Teranishi, Nobukazu
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 2014, 61 (06) : 2093 - 2097
  • [23] Wild-type Blocking PCR Combined with Direct Sequencing as a Highly Sensitive Method for Detection of Low-Frequency Somatic Mutations
    Albitar, Adam Z.
    Ma, Wanlong
    Albitar, Maher
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2017, (121):
  • [24] CMOS rectifier design for RFID chip with high sensitivity at low input power to be combined with an ultrasmall antenna
    Jantarachote, Vasan
    Tontisirin, Sitt
    Akkaraekthalin, Prayoot
    Negra, Renato
    Chalermwisutkul, Suramate
    INTERNATIONAL JOURNAL OF NUMERICAL MODELLING-ELECTRONIC NETWORKS DEVICES AND FIELDS, 2019, 32 (06)
  • [25] Improving design and fault detection in linear and nonlinear high frequency circuits by performing a sensitivity based analysis
    Sylla, IT
    Slamani, M
    ANALOG INTEGRATED CIRCUITS AND SIGNAL PROCESSING, 2001, 27 (03) : 249 - 260
  • [26] A Novel Design and Analysis of High-Sensitivity Biosensor Based on Nano-Cavity for Detection of Blood Component, Diabetes, Cancer and Glucose Concentration
    Sani, Mojtaba Hosseinzadeh
    Khosroabadi, Saeed
    IEEE SENSORS JOURNAL, 2020, 20 (13) : 7161 - 7168
  • [27] Design and synthesis of ICT-based fluorescent probe for high-sensitivity protein detection and application to rapid protein staining for SDS-PAGE
    Suzuki, Yoshio
    Yokoyama, Kenji
    PROTEOMICS, 2008, 8 (14) : 2785 - 2790
  • [28] Rapid-Response, Low Detection Limit, and High-Sensitivity Capacitive Flexible Tactile Sensor Based on Three-Dimensional Porous Dielectric Layer for Wearable Electronic Skin
    Qiu, Jie
    Guo, Xiaohui
    Chu, Ran
    Wang, Siliang
    Zeng, Wei
    Qu, Lei
    Zhao, Yunong
    Yan, Feng
    Xing, Guozhong
    ACS APPLIED MATERIALS & INTERFACES, 2019, 11 (43) : 40716 - 40725