High-Power Short-Duration Temperature-Controlled Radiofrequency Ablation for the Treatment of Outflow Tract Ventricular Arrhythmias

被引:0
作者
Leftheriotis, Dionyssios [1 ]
Flevari, Panagiota [1 ]
Papathanasiou, Konstantinos A. [1 ]
Karamanolis, Efstratios [1 ]
Gkatzia, Alexandra [1 ]
Polykandrioti, Maria [2 ]
Filippatos, Gerasimos [1 ]
机构
[1] Natl & Kapodistrian Univ Athens, Univ Gen Hosp Attikon, Med Sch, Dept Cardiol 2, Athens, Greece
[2] Univ West Attica, Dept Nursing, Athens, Greece
关键词
ablation; efficacy; outflow ventricular tachycardia; safety; temperature-controlled catheter; PULMONARY VEIN ISOLATION; TACHYCARDIA ABLATION; CATHETER ABLATION;
D O I
10.1111/jce.16636
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: The tissue temperature-controlled DiamondTemp ablation (DTA) catheter has been mainly used for atrial fibrillation ablation. We report our initial experience in using this catheter for the treatment of outflow premature ventricular contractions (PVCs) or repetitive non-sustained monomorphic ventricular tachycardias (VTs). Methods Twenty patients were studied: 10 with right ventricular outflow tract PVCs/VTs, eight with PVCs/VTs from the aortic sinus cusps, and two with left ventricular outflow tract PVCs. The DTA parameters were adjusted to a target-temperature of 60 degrees C with 50 W power. Ablation success was defined as the absence of clinical VT/PVCs at the end of the procedure and during the next 48 h of continuous rhythm monitoring without antiarrhythmic drugs. All patients were reevaluated 2 months after the ablation. Results: The average ablation duration was 262 (145-690) seconds and the average tissue temperature (T) was 50.4 +/- 2.9 degrees C. A mean number of 11 +/- 6 lesions per case were applied. The average time of T > 50 degrees C was 18 (12-20) seconds, that is 70% of the ablation time, and an average relative impedance drop of 13.8 +/- 2.0% was recorded. No serious complications occurred, and no VT recurrence was observed until discharge and during the short follow-up period. Conclusion: This initial evaluation suggests that the DTA system reached the adjusted temperature and power targets, and it can be effectively and safely applied for the treatment of outflow tract PVCs/VTs. This performance should be further evaluated by long-term randomized controlled trials in comparison to conventional ablation catheters.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Safety and efficacy of delivering high-power short-duration radiofrequency ablation lesions utilizing a novel temperature sensing technology
    Rozen, Guy
    Ptaszek, Leon M.
    Zilberman, Israel
    Douglas, Victoria
    Heist, E. Kevin
    Beeckler, Christopher
    Altmann, Andres
    Ruskin, Jeremy N.
    Govari, Assaf
    Mansour, Moussa
    EUROPACE, 2018, 20 : F444 - F450
  • [32] Treatment of Macro-Reentry Atrial Tachycardia with Very High-Power, Short-Duration, Temperature-Controlled Ablation of Anterior Line Using an Open-Irrigated Ablation Catheter with Microelectrodes
    Heeger, Christian
    Vogler, Julia
    Kirstein, Bettina
    Eitel, Charlotte
    Tilz, Roland R.
    AMERICAN JOURNAL OF CASE REPORTS, 2021, 22
  • [33] High-power short-duration versus low-power long-duration ablation guided by the ablation index
    Sousa, Pedro A.
    Puga, Luis
    Barra, Sergio
    Adao, Luis
    Primo, Joao
    Khoueiry, Ziad
    Lebreiro, Ana
    Fonseca, Paulo
    Pereira, Mariana
    Lagrange, Philippe
    D'Avila, Andre
    Oliveiros, Barbara
    Elvas, Luis
    Goncalves, Lino
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2023, 370 : 209 - 214
  • [34] Meta-analysis of high-power short-duration versus cryoballoon ablation for atrial fibrillation
    Lin, Limin
    Huang, Ying
    Huang, Qunying
    Yu, Fuling
    Mao, Yinjun
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2024, 47 (08): : 1013 - 1024
  • [35] Triple gastrointestinal prophylactic therapy following high-power short-duration posterior left atrial wall ablation
    Candemir, Basar
    Baskovski, Emir
    Mammadov, Mammad
    Esenboga, Kerim
    Altin, Timucin
    INDIAN HEART JOURNAL, 2020, 72 (04) : 306 - 308
  • [36] Multicenter prospective comparison of conventional and high-power short duration radiofrequency application for pulmonary vein isolation: the high-power short-duration radiofrequency application for faster and safer pulmonary vein ablation (POWER FAST III) trial
    Castrejon-Castrejon, Sergio
    Cossiani, Marcel Martinez
    Jauregui-Abularach, Miguel
    Sola, Nuria Basterra
    Criado, Jose Luis Ibanez
    Asensi, Joaquin Osca
    Luque, Ivo Roca
    Mitjans, Angel Moya
    Dorador, Aurelio Quesada
    Olivares, Victor Manuel Hidalgo
    Castellano, Nicasio Perez
    Gomez, Juan Manuel Fernandez
    Macias-Ruiz, Maria Rosa
    Villanueva, Bruno Bochard
    Bada, Nerea Gonzalo
    Prieto, Andres Fernandez
    Lopez, Leonardo Elias Guido
    Maldonado, Maria Eugenia Martinez
    Merino, Daniel
    Cervantes, Carlos Escobar
    Merino, Jose Luis
    OWER FAST III trial invest
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2023, 66 (08) : 1889 - 1899
  • [37] Very High-Power Short-Duration Ablation for Atrial Fibrillation in Adults With Congenital Heart Disease
    Lengauer, Sarah
    Erhard, Nico
    Popa, Miruna A.
    Telishevska, Marta
    Krafft, Hannah
    Bahlke, Fabian
    Englert, Florian
    Bourier, Felix
    Reents, Tilko
    Deisenhofer, Isabel
    Hessling, Gabriele
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2025, : 625 - 631
  • [38] Optimal conditions for high-power, short-duration radiofrequency ablation using a novel, flexible- tipped, force-sensing catheter
    Piccini, Jonathan P.
    Dave, Amish S.
    Holmes, Douglas S.
    Winter, Jeffrey R.
    Tranter, John H.
    Pipenhagen, Catherine
    Moon, L. Boyce
    Ambrosius, Nicholas M.
    Overmann, Jed A.
    Boudlali, Hana
    Thao, Riki
    Geurkink, Chris
    Thamavong, Zada
    Jensen, James A.
    Fish, Jeffrey M.
    HEART RHYTHM O2, 2023, 4 (07): : 440 - 447
  • [39] Comparison of high-power short-duration and low-power long-duration radiofrequency ablation for treating atrial fibrillation: Systematic review and meta-analysis
    Chen, Chao-feng
    Wu, Jing
    Jin, Chao-lun
    Liu, Mei-jun
    Xu, Yi-zhou
    CLINICAL CARDIOLOGY, 2020, 43 (12) : 1631 - 1640
  • [40] Bipolar Radiofrequency Catheter Ablation for Refractory Ventricular Outflow Tract Arrhythmias
    Teh, Andrew W.
    Reddy, Vivek Y.
    Koruth, Jacob S.
    Miller, Marc A.
    Choudry, Subbarao
    D'Avila, Andre
    Dukkipati, Srinivas R.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2014, 25 (10) : 1093 - 1099