Total Thrombus-Formation System in Patients with Peripheral Artery Disease

被引:0
作者
Pfrepper, Christian [1 ]
Franke, Careen [1 ]
Metze, Michael [2 ]
Weise, Maria [1 ]
Siegemund, Annelie [1 ,3 ]
Siegemund, Roland [3 ]
Federbusch, Martin [4 ]
Henschler, Reinhard [5 ]
Petros, Sirak [1 ,3 ]
Konert, Manuela [6 ,7 ]
机构
[1] Univ Leipzig, Div Hemostaseol, Med Ctr, Liebigstr 20, D-04103 Leipzig, Germany
[2] Univ Leipzig, Dept Cardiol, Med Ctr, Leipzig, Germany
[3] Univ Leipzig, Med Ctr, Med ICU, Leipzig, Germany
[4] Univ Leipzig, Inst Lab Med, Med Ctr, Leipzig, Germany
[5] Univ Leipzig, Inst Transfus Med, Med Ctr, Leipzig, Germany
[6] Univ Leipzig, Dept Angiol, Med Ctr, Leipzig, Germany
[7] Dr Horst Schmidt Kliniken Wiesbaden, Div Angiol, Wiesbaden, Germany
关键词
antiplatelet monitoring; clopidogrel; dual antiplatelet therapy; peripheral artery disease; T-TAS; FLOW-CHAMBER SYSTEM; CLOPIDOGREL; THROMBOGENICITY; DEFINITION; ASPIRIN;
D O I
10.1177/10760296241301412
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The Total Thrombus-formation Analysis System (T-TAS) is an automated device using coated microchips to assess thrombus formation under flow conditions. Its value to monitor coagulation function in patients under antiplatelet therapy awaits further clarification. This study evaluated T-TAS to detect response to dual antiplatelet therapy (DAPT) in patients with peripheral artery disease (PAD). T-TAS using the platelet-chip (PL-chip) and atheroma-chip (AR-chip) was performed in 60 patients with PAD on the day after lower extremity revascularization. Results were compared with light transmission aggregometry (LTA) and multiple electrode aggregometry (MEA, ADP- and ASPI-test). To determine T-TAS reference ranges, 30 healthy blood donors were enrolled. The area under the curve of the PL-chip (AUC-PL) was outside the reference range in 91.2% and AUC-AR in 21.1% of the PAD patients. Low responders in MEA ASPI, MEA ADP or both tests and low responders in LTA induced by ADP had a significantly higher AUC-PL compared to responders (204 vs 70, p = .016 and 140 vs 32, p < .001), respectively. Median AUC-PL in low responders in LTA and MEA, LTA or MEA and in responders in LTA and MEA was 301, 104 and 32 (p = .001), respectively. Our results suggest that the PL-chip can continuously assess the level of response to DAPT and might be helpful to monitor PAD patients.
引用
收藏
页数:10
相关论文
共 50 条
[11]   Evaluation of the Total Thrombus-Formation System (T-TAS): application to human and mouse blood analysis [J].
Al Ghaithi, Rashid ;
Mori, Jun ;
Nagy, Zoltan ;
Maclachlan, Annabel ;
Hardy, Lewis ;
Philippou, Helen ;
Hethershaw, Emma ;
Morgan, Neil, V ;
Senis, Yotis A. ;
Harrison, Paul .
PLATELETS, 2019, 30 (07) :893-900
[12]   Total Thrombus-Formation Analysis System (T-TAS) Can Predict Periprocedural Bleeding Events in Patients Undergoing Catheter Ablation for Atrial Fibrillation [J].
Ito, Miwa ;
Kaikita, Koichi ;
Sueta, Daisuke ;
Ishii, Masanobu ;
Oimatsu, Yu ;
Arima, Yuichiro ;
Iwashita, Satomi ;
Takahashi, Aya ;
Hoshiyama, Tadashi ;
Kanazawa, Hisanori ;
Sakamoto, Kenji ;
Yamamoto, Eiichiro ;
Tsujita, Kenichi ;
Yamamuro, Megumi ;
Kojima, Sunao ;
Hokimoto, Seiji ;
Yamabe, Hiroshige ;
Ogawa, Hisao .
JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2016, 5 (01)
[13]   Antithrombotic Strategies for Patients With Peripheral Artery Disease [J].
Bonaca, Marc P. ;
Barnes, Geoffrey D. ;
Bauersachs, Rupert ;
Bessada, Youssef ;
Conte, Michael S. ;
Dua, Anahita ;
Hess, Connie N. ;
Serhal, Maya ;
Mena-Hurtado, Carlos ;
Weitz, Jeffrey I. ;
Beckman, Joshua A. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 84 (10) :936-952
[14]   Evaluation of the antithrombotic abilities of non-vitamin K antagonist oral anticoagulants using the Total Thrombus-formation Analysis System® [J].
Idemoto, Yoshiaki ;
Miura, Shin-ichiro ;
Norimatsu, Kenji ;
Suematsu, Yasunori ;
Hitaka, Yuka ;
Shiga, Yuhei ;
Morii, Joji ;
Imaizumi, Satoshi ;
Kuwano, Takashi ;
Iwata, Atsushi ;
Zhang, Bo ;
Ogawa, Masahiro ;
Saku, Keijiro .
HEART AND VESSELS, 2017, 32 (03) :309-316
[15]   The Utility of Total Thrombus-Formation Analysis System (T-TAS) in the Thrombosis and Hemostasis Field: A Scoping Review [J].
Mansouritorghabeh, H. ;
Monard, A. ;
Heubel-Moenen, F. ;
Leentjens, J. ;
Stroobants, A. ;
Henskens, Y. .
INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2025, 47 (02) :201-211
[16]   Cardiovascular risk factors are associated with augmented thrombogenicity in healthy individuals: analysis using the Total Thrombus-formation Analysis System [J].
Oda, Yuu ;
Ito, Takashi ;
Yamada, Yoichiro ;
Koga, Tadashi ;
Nagasato, Tomoka ;
Ohnishi-Wada, Tomoko ;
Hosokawa, Kazuya ;
Fukase, Hiroyuki ;
Hashiguchi, Teruto ;
Maruyama, Ikuro .
THROMBOSIS JOURNAL, 2021, 19 (01)
[17]   Platelet reactivity testing in peripheral artery disease [J].
Zhang, Youqi ;
Chou, Jennifer W. ;
Huang, Wan-Ting ;
Derry, Katrina ;
Humber, Doug .
AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 2022, 79 (16) :1312-1322
[18]   New methodological approaches for assessing thrombus formation in cardiovascular disease [J].
Hosokawa, Kazuya ;
Ohnishi-Wada, Tomoko ;
Nagasato, Tomoka ;
Sameshima-Kaneko, Hisayo ;
Oyamada, Chiaki ;
Dahlen, Jeffrey .
KARDIOLOGIA POLSKA, 2020, 78 (7-8) :667-673
[19]   Dual pathway inhibition in patients with peripheral artery disease in Germany [J].
Herold, Joerg ;
Dagkonakis, Nikolaos ;
Sebastian Debus, E. ;
Rauch-Kroehnert, Ursula ;
Zeymer, Uwe ;
Bauersachs, Rupert M. .
VASA-EUROPEAN JOURNAL OF VASCULAR MEDICINE, 2025, 54 (02) :142-149
[20]   Evaluation of the potential utility of the total thrombus-formation analysis system in comparison to the platelet function analyser in subjects with primary haemostatic defects [J].
Charpy, Juliette ;
Chaghouri, Pierre-Elian ;
Benattar, Norbert ;
Castet, Sabine-Marie ;
Huguenin, Yoann ;
James, Chloe ;
Fiore, Mathieu .
BRITISH JOURNAL OF HAEMATOLOGY, 2020, 191 (01) :E7-E10