Proposal of a new method for interpreting the concentrations of gases dissolved in mineral transformer oil

被引:0
作者
Piotrowski, Tomasz [1 ]
机构
[1] Lodz Univ Technol, Inst Elect Power Engn, ul B Stefanowskiego 20, PL-90537 Lodz, Poland
来源
PRZEGLAD ELEKTROTECHNICZNY | 2024年 / 100卷 / 12期
关键词
power transformer; oil-paper insulation; diagnostics; DGA; FAULT;
D O I
10.15199/48.2024.12.35
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The measurement and subsequent interpretation of the concentrations of gases dissolved in mineral oil is one of the basic procedures allowing the assessment of the technical condition of power transformers with oil-paper insulation. The article proposes a new method for interpreting measured gas concentrations. The achieved fault recognition efficiency is comparable to other classical methods and, in the case of partial discharges (PD), significantly exceeds them.
引用
收藏
页码:153 / 156
页数:4
相关论文
共 10 条
[1]   A Reviewed Turn at of Methods for Determining the Type of Fault in Power Transformers Based on Dissolved Gas Analysis [J].
Aciu, Ancuta-Mihaela ;
Enache, Sorin ;
Nitu, Maria-Cristina .
ENERGIES, 2024, 17 (10)
[2]   Conventional methods of dissolved gas analysis using oil-immersed power transformer for fault diagnosis: A review [J].
Ali, Mohd Syukri ;
Bakar, Ab Halim Abu ;
Omar, Azimah ;
Jaafar, Amirul Syafiq Abdul ;
Mohamed, Siti Hajar .
ELECTRIC POWER SYSTEMS RESEARCH, 2023, 216
[3]  
[Anonymous], 2022, IEC 60599
[4]  
[Anonymous], 2019, Advances in DGA interpretation, Technical Brochure, V771
[5]  
[Anonymous], 2009, IEEE STD C57104 2008, pC1
[6]   Assessment of Computational Intelligence and Conventional Dissolved Gas Analysis Methods for Transformer Fault Diagnosis [J].
Faiz, Jawad ;
Soleimani, Milad .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2018, 25 (05) :1798-1806
[7]   Dissolved Gas Analysis Evaluation in Electric Power Transformers using Conventional Methods a Review [J].
Faiz, Jawad ;
Soleimani, Milad .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (02) :1239-1248
[8]   Novel Four-Gas Fault Interpretation Graphical Technique for Mineral Oil Transformer [J].
Patil, Atul Jaysing ;
Naresh, Ram ;
Jarial, Raj Kumar ;
Malik, Hasmat .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2024, 31 (05) :2721-2730
[9]   Effectiveness assessment of selected graphical techniques for the interpretation of measured concentrations of gases dissolved in transformer oil [J].
Piotrowski, Tomasz .
PRZEGLAD ELEKTROTECHNICZNY, 2019, 95 (08) :57-60
[10]  
Sood Y.R, 2011, INT J COMPUTER ELECT, V3, P577