Transcatheter aortic valve replacement in a bicuspid aortic valve with membranous interventricular septum aneurysm communicating with aortic root: a case report

被引:0
|
作者
Xi, Ziwei [1 ]
Yao, Jing [1 ]
Song, Guangyuan [1 ]
机构
[1] Capital Med Univ, Beijing Anzhen Hosp, Intervent Ctr Valvular Heart Dis, 2 Anzhen Rd, Beijing 100029, Peoples R China
关键词
Transcatheter aortic valve replacement; Membranous interventricular septum aneurysm; Case report;
D O I
10.1093/ehjcr/ytae523
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Membranous interventricular septum aneurysm (MISA) is a rare abnormality occurring in 0.3% of patients with congenital heart disease, which thereby increases anatomical complexity.Case summary Transcatheter aortic valve replacement (TAVR) procedure was planned for a 71-year-old female patient from East Asia with a type 1 bicuspid aortic valve diagnosed with severe aortic stenosis by transthoracic echocardiography (TTE). Pre-procedural multidetector computed tomography (MDCT) clearly revealed an extremely horizontal aorta and a MISA originating from the sub-annulus with the upper edge extending 7.2 mm above the annulus. A probable communicating flow between the left ventricle and the aorta was confirmed by reviewing the TTE images. Moreover, there was a calcified raphe between the left- and right-coronary cusps. A downsized balloon-expandable valve (a 23 mm Sapien 3 valve with an additional 2 mL dilation) was therefore chosen and deployed with a 100/0 aortic/ventricular ratio position. The TTE post-implantation indicated a trace perivalvular leakage. The cardiac MDCT performed post-procedure, at the 6-month, and 12-month follow-ups demonstrated complete sealing and significant healing of the aneurysm.Discussion Transcatheter aortic valve replacement utilizing a balloon-expandable valve was successfully performed for a case with membranous interventricular septum aneurysm extending above the annulus. Comprehensive imaging analysis before the procedure is crucial for TAVR with challenging anatomical conditions.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Transcatheter Aortic Valve Replacement forAortic Valve Stenosis Case Report
    Bump, Jamie
    Tennyson, Carolina
    DIMENSIONS OF CRITICAL CARE NURSING, 2025, 44 (01)
  • [22] Transcatheter Aortic Valve Replacement for Severe Aortic Stenosis Complicated by Sigmoid Septum
    Yamashita, Kizuku
    Fujita, Tomoyuki
    Fukushima, Satsuki
    Shimahara, Yusuke
    Kume, Yuta
    Matsumoto, Yorihiko
    Kawamoto, Naonori
    Minami, Kimito
    Kabata, Daijiro
    Kanzaki, Hideaki
    Izumi, Chisato
    Anzai, Toshihisa
    Kobayashi, Junjiro
    CIRCULATION JOURNAL, 2018, 82 (12) : 3090 - +
  • [23] Transcatheter aortic valve replacement after valve-sparing aortic root surgery
    Tugulan, Carmen I.
    Bedi, Ryan
    Jacks, Danielle
    Parrino, Eugene P.
    Spindel, Stephen M.
    JOURNAL OF CARDIAC SURGERY, 2021, 36 (06) : 2117 - 2120
  • [24] Coronary Access After Transcatheter Aortic Valve Replacement in Patients With Bicuspid Aortic Valve Lights and Shades
    Tarantini, Giuseppe
    Fabris, Tommaso
    Cardaioli, Francesco
    Fovino, Luca Nai
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (12) : 1190 - 1191
  • [25] Successful transcatheter aortic valve replacement in an oversized 800 mm(2) annulus and bicuspid aortic valve
    Buchanan, Kyle D.
    Rogers, Toby
    Shults, Christian
    Ben-Dor, Itsik
    Satler, Lowell F.
    Waksman, Ron
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2018, 19 (08) : S65 - S67
  • [26] Biomechanical modeling of transcatheter aortic valve replacement in a stenotic bicuspid aortic valve: deployments and paravalvular leakage
    Karin Lavon
    Gil Marom
    Matteo Bianchi
    Rotem Halevi
    Ashraf Hamdan
    Adi Morany
    Ehud Raanani
    Danny Bluestein
    Rami Haj-Ali
    Medical & Biological Engineering & Computing, 2019, 57 : 2129 - 2143
  • [27] Patient-Specific Computer Simulation of Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve Morphology
    Dowling, Cameron
    Bavo, Alessandra M.
    El Faquir, Nahid
    Mortier, Peter
    de Jaegere, Peter
    De Backer, Ole
    Sondergaard, Lars
    Ruile, Philipp
    Mylotte, Darren
    McConkey, Hannah
    Rajani, Ronak
    Laborde, Jean-Claude
    Brecker, Stephen J.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2019, 12 (10)
  • [28] Outcomes of Cerebral Embolic Protection for Bicuspid Aortic Valve Stenosis Undergoing Transcatheter Aortic Valve Replacement
    Zhang, Jiajun
    Li, Xiaoxing
    Tian, Rui
    Zong, Mengzhi
    Gu, Xinghua
    Xu, Feng
    Chen, Yuguo
    Li, Chuanbao
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2023, 12 (12):
  • [29] Membranous septum length predicts conduction disturbances following transcatheter aortic valve replacement
    Chen, Ying-Hwa
    Chang, Hsiao-Huang
    Liao, Tan-Wei
    Leu, Hsin-Bang
    Chen, I-Ming
    Chen, Po-Lin
    Lin, Su-Man
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2022, 164 (01) : 42 - +
  • [30] Transcatheter Aortic Valve Replacement in Low -Risk Patients With Symptomatic Severe Bicuspid Aortic Valve Stenosis
    Waksman, Ron
    Craig, Paige E.
    Torguson, Rebecca
    Asch, Federico M.
    Weissman, Gaby
    Ruiz, Daniel
    Gordon, Paul
    Ehsan, Afshin
    Parikh, Puja
    Bilfinger, Thomas
    Levitt, Robert
    Hahn, Chiwon
    Roberts, David
    Ingram, Michael
    Hanna, Nicholas
    Comas, George
    Zhang, Cheng
    Ben-Dor, Itsik
    Satler, Lowell F.
    Garcia-Garcia, Hector M.
    Shults, Christian
    Rogers, Toby
    JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (09) : 1019 - 1027