Model-Based Assessment of Energy Efficiency in Industrial Pump Systems: A Case Study Approach

被引:0
作者
Lavric, Henrik [1 ]
Drobnic, Klemen [1 ]
Fiser, Rastko [1 ]
机构
[1] Univ Ljubljana, Fac Elect Engn, Trzaska Cesta 25, Ljubljana 1000, Slovenia
来源
APPLIED SCIENCES-BASEL | 2024年 / 14卷 / 22期
关键词
variable-speed drive; induction motor; synchronous reluctance motor; centrifugal pump; energy efficiency; energy auditing; VARIABLE-SPEED DRIVES; INDUCTION; STRATEGIES; SAVINGS; MOTORS;
D O I
10.3390/app142210430
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Outdated, oversized variable speed pump drives (VSDPs) in industry lead to sub-optimal energy efficiency and considerable energy losses. This paper proposes methods to develop 2D efficiency maps for motors, converters, and pumps using polynomial surface fitting, which enables efficiency evaluation in a wide operating range. The method was applied to an oversized VSDP in an industrial chilled water supply system, comparing the original system with five alternative VSDP combinations with high-efficiency motors and pumps. The five VSDP variants demonstrated average energy savings of around 30%, with the synchronous reluctance motor (SRM) configurations outperforming the induction motor (IM) configurations by up to 7 percentage points, particularly at low loads. The high-efficiency SRM-based 252-IE5 variant delivered the best overall energy performance, highlighting the benefits of optimised system sizing and motor selection for energy savings. The proposed method can be used in both industrial and residential applications and offers great advantages in process systems that require variable flow and pressure of water or other fluids during operation, such as HVAC, water supply and wastewater treatment, district heating, etc. The development of a VSDP drive with efficient energy optimisation is an interdisciplinary problem of mechanical and electrical engineering, and without the interaction of engineers from both fields the result will not be optimal. We try to present our method so that it can be a reliable tool for mechanical, electrical, and other engineers or researchers to assist them in finding possible energy savings, performing energy audits, and selecting the most suitable components when modernising existing or developing new systems.
引用
收藏
页数:30
相关论文
共 56 条
[1]   A review on energy saving strategies in industrial sector [J].
Abdelaziz, E. A. ;
Saidur, R. ;
Mekhilef, S. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2011, 15 (01) :150-168
[2]   On the energy optimized control of standard and high-efficiency induction motors in CT and HVAC applications [J].
Abrahamsen, F ;
Blaabjerg, F ;
Pedersen, JK ;
Grabowski, PZ ;
Thogersen, P .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1998, 34 (04) :822-831
[3]   Estimation of pump operational state with model-based methods [J].
Ahonen, Tero ;
Tamminen, Jussi ;
Ahola, Jero ;
Viholainen, Juha ;
Aranto, Niina ;
Kestila, Juha .
ENERGY CONVERSION AND MANAGEMENT, 2010, 51 (06) :1319-1325
[4]  
[Anonymous], 2021, DriveSize User Manual ABB Oy/Drives
[5]  
[Anonymous], 2024, Curve fitting toolbox-MATLAB
[6]  
[Anonymous], 2018, Standard on Efficiency Classes for Low Voltage AC Motors
[7]  
[Anonymous], 2019, The Facts Worth Knowing About AC Drives
[8]  
[Anonymous], 2010, Electric Motors and Variable Speed Drives: Standards and Legal Requirements for the Energy Efficiency of Low-Voltage Three-Phase Motors
[9]   A new approach for the prediction of speed-adjusted pump efficiency curves [J].
Coelho, Bernardete ;
Andrade-Campos, Antonio G. .
JOURNAL OF HYDRAULIC RESEARCH, 2016, 54 (05) :586-593
[10]  
DriveSize ABB, 2022, Oy/Drives