Numerical Investigations on the Start-Up Characteristics and Heat Transfer Performance of a Single-Loop Oscillating Heat Pipe With Different Surface Wettable Vertical Tubes

被引:0
作者
Chinchedu, Raghuvaran [1 ]
Kumar, K. Kiran [1 ]
Chandramohan, V. P. [1 ]
机构
[1] Natl Inst Technol Warangal, Dept Mech Engn, Waranga 506004, Telangana, India
来源
ASME JOURNAL OF HEAT AND MASS TRANSFER | 2025年 / 147卷 / 05期
关键词
conductance; hydrophilic; slug motion; start-up characteristics; super-hydrophilic; super-hydrophobic; wettability; THERMAL PERFORMANCE; SIMULATION; PRESSURE; ENERGY; WATER; FLOW;
D O I
10.1115/1.4067340
中图分类号
O414.1 [热力学];
学科分类号
摘要
The heat transfer performance of an oscillating heat pipe (OHP) was significantly enhanced by changing the inner wall surface wettability and filling ratios. Among the various wettability types, a hybrid surface, where the evaporator and condenser have different wettability, has shown enhancement of heat transfer performance significantly. The effects of different surface wettable vertical tubes are yet to be investigated. Therefore, in this study, a single-loop OHP with three different surface wettable vertical tubes, namely, alternate wettability OHP (AWOHP) were numerically investigated at different filling ratios of 30-90%. The different wettability rates of two vertical tubes caused an uneven distribution of slugs and plugs, which generated an unbalanced pressure difference between the tubes, thereby reducing the start-up time by 60-79%. The bulk mean temperature of the left and right adiabatic tubes was investigated to understand the nature of fluid flow. For filling ratios (FRs) of 30-70%, the right tube temperature was always higher than the left tube in AWOHP 3 (hydrophilic left tube, super-hydrophobic right tube), indicating unidirectional circulatory flow, with an occasional change in direction at 70% FR. At lower FR of 30%, AWOHP 2 (super-hydrophilic left tube, super-hydrophobic right tube) exhibited the highest heat transfer performance. In contrast, at higher FRs of 50-90%, AWOHP 3 exhibited the highest heat transfer performance with conductance (G) of 1075 W/m2 K at an FR of 70%, 55% higher than conventional oscillating heat pipe (COHP).
引用
收藏
页数:12
相关论文
共 57 条
  • [31] Experimental studies of surface modified oscillating heat pipes
    Leu, Tzong-Shyng
    Wu, Cheng-Han
    [J]. HEAT AND MASS TRANSFER, 2017, 53 (11) : 3329 - 3340
  • [32] Numerical investigation on the start-up and heat transfer performance of dual-diameter pulsating heat pipes
    Liu, Yuewen
    Dan, Dan
    Wei, Mingshan
    Zheng, Siyu
    Sun, Jixian
    [J]. APPLIED THERMAL ENGINEERING, 2024, 236
  • [33] Energy and cost savings potential of oscillating heat pipes for waste heat recovery ventilation
    Mahajan, Govinda
    Thompson, Scott M.
    Cho, Heejin
    [J]. ENERGY REPORTS, 2017, 3 : 46 - 53
  • [34] Surface wettability modifications and applications in wickless heat pipes
    Malla, Laxman Kumar
    Dhanalakota, Praveen
    Dileep, Hemanth
    Mahapatra, Pallab Sinha
    Pattamatta, Arvind
    [J]. SURFACES AND INTERFACES, 2024, 45
  • [35] Modeling and Experimental Data Analysis of Oscillating Heat Pipes: A Review
    Mohammadian, Shahabeddin K.
    Mohammed, Ramy H.
    Nunez, Roberto
    Rupam, Tahmid
    Spitzenberger, Jeremy
    Hoelle, James
    Ibrahim, Omar T.
    Feng, Frank Z.
    Miller, Alex
    Taft, Brenton
    Allison, Jonathan
    Abu-Heiba, Ahmed
    Mahderekal, Isaac
    Ma, Hongbin
    [J]. ASME JOURNAL OF HEAT AND MASS TRANSFER, 2024, 146 (11):
  • [36] MONTEITH J.L., 1973, Principles of environmental physics
  • [37] Thermal performance of a single loop pulsating heat pipe with asymmetric adiabatic channel
    Patel, Est Dev
    Kumar, Subrata
    [J]. APPLIED THERMAL ENGINEERING, 2023, 219
  • [38] Reid R.C., 1987, The properties of gases and liquids
  • [39] Heat-transfer characteristics of a closed-loop oscillating heat-pipe with check valves
    Rittidech, S.
    Pipatpaiboon, N.
    Terdtoon, P.
    [J]. APPLIED ENERGY, 2007, 84 (05) : 565 - 577
  • [40] Thermal performance of horizontal closed-loop oscillating heat-pipe with check valves
    Rittidech, S.
    Pipatpaiboon, N.
    Thongdaeng, S.
    [J]. JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2010, 24 (02) : 545 - 550