Testing of a Novel Method for Securing Ligaments Against Bone During Simultaneous Medial and Lateral Elbow Ligament Reconstruction

被引:1
作者
Gibbs, Christopher M. [1 ]
Combs, Taylor N. [2 ]
Nelson, Brody K. [2 ]
Kaufmann, Robert A. [1 ]
机构
[1] Univ Pittsburgh, Dept Orthopaed Surg, Kaufmann Med Bldg, 3471 Fifth Ave, Suite 1010, Pittsburgh, PA 15213 USA
[2] Element Mat Technol, Wixom, MI USA
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2024年 / 49卷 / 11期
关键词
Elbow; instability; ligament; novel; reconstruction; BIOMECHANICAL EVALUATION; TENSION;
D O I
10.1016/j.jhsa.2023.02.008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose A ligament reconstruction method that simultaneously tensions the medial and lateral sides of the elbow and maintains tension with compression plates on the proximal ulna is proposed for the treatment of bidirectional elbow ligament instability. Graft slippage, catastrophic failure, and excessive displacement were evaluated. Biomechanical stability without graft slippage was hypothesized. Methods Eight cadaveric ligament reconstruction simulations were created through the dissection of three cadaver arms. Each reconstruction was statically tested with 160 N in a manner where it was first augmented with an absorbable suture and then without. Then, 3 more ligament reconstruction simulations were created for dynamic testing with each undergoing testing at 80 N for 2,000 cycles at 2 Hz. Construct displacement and graft slippage were recorded for each load application. Results No grafts failed catastrophically and no graft slippage was observed with either static or dynamic loading. Under static loading, the mean change in displacement between augmented and nonaugmented ligament reconstruction simulations was 28.7% +/- 21% (augmented 3.95 +/- 1.81 mm vs nonaugmented 4.89 +/- 2.22 mm). The mean stiffness was 66.6 +/- 26.6 N/mm for augmented and 64.6 +/- 23.2 N/mm for nonaugmented simulations. With dynamic loading, the mean displacement for augmented graft ligament reconstruction simulations was 1.55 +/- 0.16 mm compared with 2.18 +/- 0.77 mm for nonaugmented reconstruction simulations. Conclusions This method of fixation to the proximal ulna for the simultaneous reconstruction of medial and lateral elbow ligaments successfully prevented graft slippage without excessive construct displacement during static and dynamic testing. Ligament augmentation with absorbable sutures decreased the construct displacement. Clinical relevance This ligament fixation method may be a viable alternative for the treatment of Copyright c0 2024 by the American Society for Surgery of the Hand. All rights reserved.)
引用
收藏
页码:1142.e1 / 1142.e8
页数:8
相关论文
共 27 条
  • [1] Biomechanical evaluation of a new ulnar collateral ligament reconstruction technique with interference screw fixation
    Ahmad, CS
    Lee, TQ
    ElAttrache, NS
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2003, 31 (03) : 332 - 337
  • [2] Aminata Iman Widya, 2019, J Clin Orthop Trauma, V10, pS123, DOI 10.1016/j.jcot.2019.05.002
  • [3] A biomechanical comparison of four reconstruction techniques for the medial collateral ligament-deficient elbow
    Armstrong, AD
    Dunning, CE
    Ferreira, LM
    Faber, KJ
    Johnson, JA
    King, GJW
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2005, 14 (02) : 207 - 215
  • [4] Operative treatment of ulnar collateral ligament injuries of the elbow in athletes
    Azar, FM
    Andrews, JR
    Wilk, KE
    Groh, D
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2000, 28 (01) : 16 - 23
  • [5] Biomechanical Functional Elbow Restoration of Acute Ulnar Collateral Ligament Tears: The Role of Internal Bracing on Gap Formation and Repair Stabilization
    Bachmaier, Samuel
    Wijdicks, Coen A.
    Verma, Nikhil N.
    Higgins, Laurence D.
    Greiner, Stefan
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2020, 48 (08) : 1884 - 1892
  • [6] Ball Craig M, 2002, Instr Course Lect, V51, P53
  • [7] Testing of Novel Total Elbow Prostheses Using Active Motion Experimental Setup
    Combs, Taylor N.
    Nelson, Brody K.
    Jackucki, Maciej
    Knopp, Brian
    Schneppendahl, Johannes
    Moody, Devon
    Kaufmann, Robert A.
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2023, 48 (03): : 312e1 - 312e10
  • [8] A survey of the tension applied to a doubled hamstring tendon graft for reconstruction of the anterior cruciate ligament
    Cunningham, R
    West, JR
    Greis, PE
    Burks, RT
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2002, 18 (09) : 983 - 988
  • [9] Das Biman, 2004, Int J Occup Saf Ergon, V10, P59
  • [10] Suture tape augmentation of the lateral ulnar collateral ligament increases load to failure in simulated posterolateral rotatory instability
    Ellwein, Alexander
    Fuessler, Luca
    Ferle, Manuel
    Smith, Tomas
    Lill, Helmut
    Pastor, Marc-Frederic
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2021, 29 (01) : 284 - 291