Multiobjective optimization guided by image quality index for limited-angle CT image reconstruction

被引:0
|
作者
He, Yu [1 ]
Wang, Chengxiang [1 ]
Yu, Wei [2 ,3 ]
Wang, Jiaxi [4 ]
机构
[1] Chongqing Normal Univ, Sch Math Sci, Chongqing 401331, Peoples R China
[2] Hubei Univ Sci & Technol, Xianning Med Coll, Sch Biomed Engn & Imaging, Xianning 437100, Peoples R China
[3] Hubei Univ Sci & Technol, Key Lab Optoeletron & Intelligent Control, Xianning, Peoples R China
[4] Chengdu Univ, Coll Comp Sci, Chengdu, Peoples R China
基金
中国国家自然科学基金;
关键词
CT reconstruction; limited-angle CT; image quality assessment; multiobjective optimization; TOTAL VARIATION MINIMIZATION; COMPUTED-TOMOGRAPHY; FRAME; TOMOSYNTHESIS; ALGORITHM;
D O I
10.3233/XST-240111
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
BACKGROUND: Due to the incomplete projection data collected by limited-angle computed tomography (CT), severe artifacts are present in the reconstructed image. Classical regularization methods such as total variation (TV) minimization, t0 minimization, are unable to suppress artifacts at the edges perfectly. Most existing regularization methods are single-objective optimization approaches, stemming from scalarization methods for multiobjective optimization problems (MOP). OBJECTIVE: To further suppress the artifacts and effectively preserve the edge structures of the reconstructed image. METHOD: This study presents a multiobjective optimization model incorporates both data fidelity term and t0-norm of the image gradient as objective functions. It employs an iterative approach different from traditional scalarization methods, using the maximization of structural similarity (SSIM) values to guide optimization rather than minimizing the objective function.The iterative method involves two steps, firstly, simultaneous algebraic reconstruction technique (SART) optimizes the data fidelity term using SSIM and the Simulated Annealing (SA) algorithm for guidance. The degradation solution is accepted in the form of probability, and guided image filtering (GIF) is introduced to further preserve the image edge when the degradation solution is rejected. Secondly, the result from the first step is integrated into the second objective function as a constraint, we use t0 minimization to optimize t0-norm of the image gradient, and the SSIM, SA algorithm and GIF are introduced to guide optimization process by improving SSIM value like the first step. RESULTS: With visual inspection, the peak signal-to-noise ratio (PSNR), root mean square error (RMSE), and SSIM values indicate that our approach outperforms other traditional methods. CONCLUSIONS: The experiments demonstrate the effectiveness of our method and its superiority over other classical methods in artifact suppression and edge detail restoration.
引用
收藏
页码:1209 / 1237
页数:29
相关论文
共 50 条
  • [41] Image acquisition optimization of a limited-angle intrafraction verification (LIVE) system for lung radiotherapy
    Zhang, Yawei
    Deng, Xinchen
    Yin, Fang-Fang
    Ren, Lei
    MEDICAL PHYSICS, 2018, 45 (01) : 340 - 351
  • [42] CROSS: Cross-Domain Residual-Optimization-Based Structure Strengthening Reconstruction for Limited-Angle CT
    Hu, Dianlin
    Zhang, Yikun
    Quan, Guotao
    Xiang, Jun
    Coatrieux, Gouenou
    Luo, Shouhua
    Coatrieux, Jean-Louis
    Ji, Xu
    Han, Hongbin
    Chen, Yang
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2023, 7 (05) : 521 - 531
  • [43] Initial Experience in Image Reconstruction from Limited-angle C-arm CBCT Data
    Zhang, Zheng
    Han, Xiao
    Bian, Junguo
    Manak, Joseph J.
    Sidky, Emil Y.
    Pan, Xiaochuan
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3977 - 3979
  • [44] Volumetric image reconstruction in a dental panoramic imaging system with a limited-angle zigzag scan geometry
    Daeki Hong
    Hyosung Cho
    Seonhwa Lee
    Jieun Oh
    Minsik Lee
    Hyojeong Kim
    Uikyu Je
    Yeonok Park
    Sungil Choi
    Yangseo Koo
    Heemoon Cho
    Journal of the Korean Physical Society, 2013, 62 : 333 - 338
  • [45] l0 Gradient Minimization Based Image Reconstruction for Limited-Angle Computed Tomography
    Yu, Wei
    Zeng, Li
    PLOS ONE, 2015, 10 (07):
  • [46] Reweighted Anisotropic Total Variation Minimization for Limited-Angle CT Reconstruction
    Wang, Ting
    Nakamoto, Katsuhiro
    Zhang, Heye
    Liu, Huafeng
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2017, 64 (10) : 2742 - 2760
  • [47] l0 regularization based on a prior image incorporated non-local means for limited-angle X-ray CT reconstruction
    Zhang, Lingli
    Zeng, Li
    Guo, Yumeng
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2018, 26 (03) : 481 - 498
  • [48] Anisotropic total variation minimization method for limited-angle CT reconstruction
    Jin, Xin
    Li, Liang
    Chen, Zhiqiang
    Zhang, Li
    Xing, Yuxiang
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VIII, 2012, 8506
  • [49] Artifact Removal Using GAN Network for Limited-Angle CT Reconstruction
    Xie, Shipeng
    Xu, Hui
    Li, Haibo
    2019 NINTH INTERNATIONAL CONFERENCE ON IMAGE PROCESSING THEORY, TOOLS AND APPLICATIONS (IPTA), 2019,
  • [50] Limited-angle image reconstruction based on Mumford-Shah-like model and wavelet tight frames
    Zhang, Lingli
    Zeng, Li
    Wang, Chengxiang
    Guo, Yumeng
    JOURNAL OF OPTICS-INDIA, 2019, 48 (01): : 3 - 17