The Effect of Corrosion on the Electrical Contact Performance of Aviation Connectors Revealed by In Situ Impedance Measurements

被引:0
作者
Zhang, Gang [1 ]
Shi, Yin [1 ]
He, Xin [2 ]
Chen, Xiao [1 ]
Duffy, Alistair [3 ]
Zhu, Meng [4 ]
Han, Zhuowei [1 ]
Wang, Lixin [2 ]
机构
[1] Harbin Inst Technol, Dept Elect Engn & Automat, Harbin 150001, Peoples R China
[2] Harbin Inst Technol, Dept Mech Engn & Automat, Shenzhen 518055, Peoples R China
[3] Montfort Univ, Dept Engn & Sustainable Dev, Leicester LE1 9BH, England
[4] AVIC Aeropolytechnol Estab, Beijing 100028, Peoples R China
来源
IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY | 2025年 / 15卷 / 01期
基金
中国国家自然科学基金;
关键词
Connectors; Contacts; Impedance; Impedance measurement; Wire; Degradation; Inductance; Corrosive environments; electrical connector; in situ measurement of impedance;
D O I
10.1109/TCPMT.2024.3448431
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This work proposes a new method to evaluate the electrical contact performance of aviation connectors by in situ measurement of broadband impedance. The broadband impedance of the wire connector under corrosive environments is measured using an inductively coupled measurement scheme, which can be conducted under operating conditions. By observing variations in the inductance and resonant frequency of measured impedance, the degradation of the connectors can be assessed more accurately and intuitively. Experiments reveal a quasi-linear degradation correspondence between the impedance of connectors and corrosion duration. Moreover, the impedance of connectors is more sensitive to corrosion-induced degradation compared to resistance, which means that potential damage to the connector can be detected earlier through the proposed in situ impedance measurement, allowing for better-informed risk management and timely repair or replacement, particularly in safety-critical situations.
引用
收藏
页码:140 / 149
页数:10
相关论文
共 20 条
  • [1] Di Troia GW, 2004, PROC IEEE-PES, P947
  • [2] Fukuyama Yasuhiro, 2018, 2018 IEEE Holm Conference on Electrical Contacts, P456, DOI 10.1109/HOLM.2018.8611634
  • [3] Horibe M, 2017, 2017 89TH ARFTG MICROWAVE MEASUREMENT CONFERENCE (ARFTG)
  • [4] High-Frequency Characterization and Modeling of Coaxial Connectors With Degraded Contact Surfaces
    Ji, Rui
    Flowers, George T.
    Gao, Jinchun
    Cheng, Zhongyang
    Xie, Gang
    [J]. IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY, 2018, 8 (03): : 447 - 455
  • [5] The Effect of Electrical Connector Degradation on High-Frequency Signal Transmission
    Ji, Rui
    Gao, Jinchun
    Flowers, George T.
    Xie, Gang
    Cheng, Zhongyang
    Jin, Qiuyan
    [J]. IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY, 2017, 7 (07): : 1163 - 1172
  • [6] VNA-Based Fixture Adapters for Wideband Accurate Impedance Extraction of Single-Phase EMI Filtering Chokes
    Jie, Huamin
    Gao, Si-Ping
    Zhao, Zhenyu
    Fan, Fei
    Sasongko, Firman
    Gupta, Amit Kumar
    See, Kye Yak
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2023, 70 (08) : 7821 - 7831
  • [7] A Survey of Impedance Measurement Methods in Power Electronics
    Jie, Huamin
    Zhao, Zhenyu
    Fei, Fan
    See, Kye Yak
    Simanjorang, Rejeki
    Sasongko, Firman
    [J]. 2022 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC 2022), 2022,
  • [8] Inductive Coupled In-Circuit Impedance Monitoring of Electrical System Using Two-Port ABCD Network Approach
    Li, Kang Rong
    See, Kye Yak
    Li, Xing Ming
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2015, 64 (09) : 2489 - 2495
  • [9] Effect of Electrical Contact Degradation on Analog Signal Transmission
    Li, Qingya
    Gao, Jinchun
    Flowers, George T.
    Xie, Gang
    Jackson, Robert L.
    [J]. IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY, 2019, 9 (12): : 2374 - 2382
  • [10] Lyu K., 2021, P GLOB REL PROG HLTH, P1