Standardization of Dual-Energy CT Iodine Uptake of the Abdomen and Pelvis: Defining Reference Values in a Big Data Cohort

被引:1
|
作者
Yel, Ibrahim [1 ,2 ]
Booz, Christian [1 ,2 ]
D'Angelo, Tommaso [3 ,4 ]
Koch, Vitali [1 ,2 ]
Gruenewald, Leon D. [1 ,2 ]
Eichler, Katrin [1 ,2 ]
Goekduman, Aynur [1 ,2 ]
Giardino, Davide [1 ]
Gaeta, Michele [3 ]
Mazziotti, Silvio [3 ]
Herrmann, Eva [5 ]
Vogl, Thomas J. [2 ]
Mahmoudi, Scherwin [1 ,2 ]
Lanzafame, Ludovica R. M. [1 ,3 ]
机构
[1] Univ Hosp Frankfurt, Dept Diagnost & Intervent Radiol, Div Expt Imaging, D-60596 Frankfurt, Germany
[2] Univ Hosp Frankfurt, Dept Diagnost & Intervent Radiol, D-60596 Frankfurt, Germany
[3] Univ Messina, BIOMORF Dept, Diagnost & Intervent Radiol Unit, I-98124 Messina, Italy
[4] Erasmus MC, Dept Radiol & Nucl Med, NL-3015 CE Rotterdam, Netherlands
[5] Goethe Univ Frankfurt, Inst Biostat & Math Modelling, D-60596 Frankfurt, Germany
关键词
contrast media; dual-energy computed tomography; iodine maps; abdominal imaging; COMPUTED-TOMOGRAPHY; MULTIDETECTOR CT; CLEAR-CELL; QUANTIFICATION; ACCURACY; THRESHOLD; PHANTOM; MAPS;
D O I
10.3390/diagnostics14182051
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: To establish dual-energy-derived iodine density reference values in abdominopelvic organs in a large cohort of healthy subjects. Methods: 597 patients who underwent portal venous phase dual-energy CT scans of the abdomen were retrospectively enrolled. Iodine distribution maps were reconstructed, and regions of interest measurements were placed in abdominal and pelvic structures to obtain absolute iodine values. Subsequently, normalization of the abdominal aorta was conducted to obtain normalized iodine ratios. The values obtained were subsequently analyzed and differences were investigated in subgroups defined by sex, age and BMI. Results: Overall mean iodine uptake values and normalized iodine ratios ranged between 0.31 and 6.08 mg/mL and 0.06 and 1.20, respectively. Women exhibited higher absolute iodine concentration across all organs. With increasing age, normalized iodine ratios mostly tend to decrease, being most significant in the uterus, prostate, and kidneys (p < 0.015). BMI was the parameter less responsible for variations in iodine concentrations; normal weighted patients demonstrated higher values of both absolute and normalized iodine. Conclusions: Iodine concentration values and normalized iodine ratios of abdominal and pelvic organs reveal significant gender-, age-, and BMI-related differences, underscoring the necessity to integrate these variables into clinical practice.
引用
收藏
页数:14
相关论文
共 23 条
  • [21] Systematic radiation dose optimization of abdominal dual-energy CT on a second-generation dual-source CT scanner: assessment of the accuracy of iodine uptake measurement and image quality in an in vitro and in vivo investigations
    Schindera, Sebastian T.
    Zaehringer, Caroline
    D'Errico, Luigia
    Schwartz, Fides
    Kekelidze, Maka
    Szucs-Farkas, Zsolt
    Benz, Matthias R.
    ABDOMINAL RADIOLOGY, 2017, 42 (10) : 2562 - 2570
  • [22] Assessment of Correlation between Dual-Energy Ct (De-Ct)-Derived Iodine Concentration and Local Flourodeoxyglucose (Fdg) Uptake in Patients with Primary Non-Small-Cell Lung Cancer
    Andersen, Michael Brun
    Drljevic-Nielsen, Aska
    Thygesen, Jesper
    Kruis, Matthijs Ferdinand
    Hjorthaug, Karin
    Rasmussen, Finn
    Nijkamp, Jasper Albertus
    TOMOGRAPHY, 2022, 8 (04) : 1770 - 1780
  • [23] Correlation of Iodine Quantification and FDG Uptake in Early Therapy Response Assessment of Non-small Cell Lung Cancer: Possible Benefit of Dual-energy CT Scan as an Integral Part of PET/CT Examination
    Baxa, Jan
    Ludvik, Jaroslav
    Sedlmair, Martin
    Flohr, Thomas
    Schmidt, Bernhard
    Hosek, Petr
    Pesek, Milos
    Svaton, Martin
    Ferda, Jiri
    ANTICANCER RESEARCH, 2020, 40 (06) : 3459 - 3468