Standardization of Dual-Energy CT Iodine Uptake of the Abdomen and Pelvis: Defining Reference Values in a Big Data Cohort

被引:1
|
作者
Yel, Ibrahim [1 ,2 ]
Booz, Christian [1 ,2 ]
D'Angelo, Tommaso [3 ,4 ]
Koch, Vitali [1 ,2 ]
Gruenewald, Leon D. [1 ,2 ]
Eichler, Katrin [1 ,2 ]
Goekduman, Aynur [1 ,2 ]
Giardino, Davide [1 ]
Gaeta, Michele [3 ]
Mazziotti, Silvio [3 ]
Herrmann, Eva [5 ]
Vogl, Thomas J. [2 ]
Mahmoudi, Scherwin [1 ,2 ]
Lanzafame, Ludovica R. M. [1 ,3 ]
机构
[1] Univ Hosp Frankfurt, Dept Diagnost & Intervent Radiol, Div Expt Imaging, D-60596 Frankfurt, Germany
[2] Univ Hosp Frankfurt, Dept Diagnost & Intervent Radiol, D-60596 Frankfurt, Germany
[3] Univ Messina, BIOMORF Dept, Diagnost & Intervent Radiol Unit, I-98124 Messina, Italy
[4] Erasmus MC, Dept Radiol & Nucl Med, NL-3015 CE Rotterdam, Netherlands
[5] Goethe Univ Frankfurt, Inst Biostat & Math Modelling, D-60596 Frankfurt, Germany
关键词
contrast media; dual-energy computed tomography; iodine maps; abdominal imaging; COMPUTED-TOMOGRAPHY; MULTIDETECTOR CT; CLEAR-CELL; QUANTIFICATION; ACCURACY; THRESHOLD; PHANTOM; MAPS;
D O I
10.3390/diagnostics14182051
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: To establish dual-energy-derived iodine density reference values in abdominopelvic organs in a large cohort of healthy subjects. Methods: 597 patients who underwent portal venous phase dual-energy CT scans of the abdomen were retrospectively enrolled. Iodine distribution maps were reconstructed, and regions of interest measurements were placed in abdominal and pelvic structures to obtain absolute iodine values. Subsequently, normalization of the abdominal aorta was conducted to obtain normalized iodine ratios. The values obtained were subsequently analyzed and differences were investigated in subgroups defined by sex, age and BMI. Results: Overall mean iodine uptake values and normalized iodine ratios ranged between 0.31 and 6.08 mg/mL and 0.06 and 1.20, respectively. Women exhibited higher absolute iodine concentration across all organs. With increasing age, normalized iodine ratios mostly tend to decrease, being most significant in the uterus, prostate, and kidneys (p < 0.015). BMI was the parameter less responsible for variations in iodine concentrations; normal weighted patients demonstrated higher values of both absolute and normalized iodine. Conclusions: Iodine concentration values and normalized iodine ratios of abdominal and pelvic organs reveal significant gender-, age-, and BMI-related differences, underscoring the necessity to integrate these variables into clinical practice.
引用
收藏
页数:14
相关论文
共 23 条
  • [1] Dual-Energy CT Iodine Uptake of Head and Neck: Definition of Reference Values in a Big Data Cohort
    Yel, Ibrahim
    Bucolo, Giuseppe Mauro
    Mahmoudi, Scherwin
    Koch, Vitali
    Goekduman, Aynur
    D'Angelo, Tommaso
    Gruenewald, Leon David
    Dimitrova, Mirela
    Eichler, Katrin
    Vogl, Thomas J.
    Booz, Christian
    DIAGNOSTICS, 2024, 14 (05)
  • [2] Dual-Energy and Dual-Source CT: Is There a Role in the Abdomen and Pelvis?
    Fletcher, Joel G.
    Takahashi, Naoki
    Hartman, Robert
    Guimaraes, Luis
    Huprich, James E.
    Hough, David M.
    Yu, Lifeng
    McCollough, Cynthia H.
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2009, 47 (01) : 41 - +
  • [3] Iodine Images in Dual-energy CT: Detection of Hepatic Steatosis by Quantitative Iodine Concentration Values
    Beck, Stefanie
    Jahn, Laurenz
    Deniffel, Dominik
    Riederer, Isabelle
    Sauter, Andreas
    Makowski, Marcus R.
    Pfeiffer, Daniela
    JOURNAL OF DIGITAL IMAGING, 2022, 35 (06) : 1738 - 1747
  • [4] Dual-Energy CT of the Abdomen and Pelvis: Radiation Dose Considerations
    Grajo, Joseph R.
    Sahani, Dushyant V.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2018, 15 (08) : 1128 - 1132
  • [5] Assessment of iodine uptake by pancreatic cancer following chemotherapy using dual-energy CT
    Kawamoto, Satomi
    Fuld, Matthew. K.
    Laheru, Daniel
    Huang, Peng
    Fishman, Elliot K.
    ABDOMINAL RADIOLOGY, 2018, 43 (02) : 445 - 456
  • [6] Evaluation of pancreatic iodine uptake and related influential factors in multiphase dual-energy CT
    Pan, Chen
    Yu, Tao
    Zhao, Heng
    He, Jiani
    Lu, Xiaomei
    Tang, Haiyan
    Hong, Yang
    Shang, Chao
    Wu, Qijun
    Yang, Aoran
    Li, Chunli
    Zhou, Minghui
    Shi, Yu
    EUROPEAN RADIOLOGY, 2024, 34 (12) : 7609 - 7621
  • [7] Iodine Images in Dual-energy CT: Detection of Hepatic Steatosis by Quantitative Iodine Concentration Values
    Stefanie Beck
    Laurenz Jahn
    Dominik Deniffel
    Isabelle Riederer
    Andreas Sauter
    Marcus R. Makowski
    Daniela Pfeiffer
    Journal of Digital Imaging, 2022, 35 : 1738 - 1747
  • [8] Selection of optimal tube potential settings for dual-energy CT virtual mono-energetic imaging of iodine in the abdomen
    Michalak, Gregory
    Grimes, Joshua
    Fletcher, Joel
    Halaweish, Ahmed
    Yu, Lifeng
    Leng, Shuai
    McCollough, Cynthia
    ABDOMINAL RADIOLOGY, 2017, 42 (09) : 2289 - 2296
  • [9] Physiological iodine uptake of the spine's bone marrow in dual-energy computed tomography - using artificial intelligence to define reference values based on 678 CT examinations of 189 individuals
    Fervers, Philipp
    Fervers, Florian
    Rinneburger, Miriam
    Weisthoff, Mathilda
    Kottlors, Jonathan
    Reimer, Robert
    Zopfs, David
    Celik, Erkan
    Maintz, David
    Grosse-Hokamp, Nils
    Persigehl, Thorsten
    FRONTIERS IN ENDOCRINOLOGY, 2023, 14
  • [10] Assessment of a single-pass venous phase CT chest, abdomen and pelvis and dual-energy CT in general oncology outpatients
    Seah, Huey Ming
    Choi, Hau Cher
    Bajic, Nicholas
    Oakden-Rayner, Lauren
    Gormly, Kirsten L.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2023, 67 (04) : 349 - 356