Impact of X-Ray Protective Drapes on Operator and Patient Radiation Exposure During Cardiac Catheterization

被引:1
作者
de Ceuninck, Michel [1 ]
Dujardin, Karl [1 ]
Vanhaverbeke, Maarten [1 ]
Muyldermans, Philip [1 ]
de Walle, Stefaan Van [1 ]
Pauwelyn, Maarten [1 ]
Bergez, Bernard [1 ]
Desimpel, Francine [2 ]
Vanderheeren, Philippe [2 ]
Dekerpel, Filip [3 ]
Kamoen, Victor [1 ]
Van Beveren, Jan [1 ]
Bruneel, Wim [4 ]
Van Coillie, Patrick [1 ]
Cokelaere, Benny [5 ]
机构
[1] AZ Delta, Dept Cardiol, Roeselare, Belgium
[2] Sint Andriesziekenhuis, Dept Cardiol, Tielt, Belgium
[3] Sint Jozefskliniek Izegem, Dept Cardiol, Izegem, Belgium
[4] AZ Delta, Dept IT & Data, Roeselare, Belgium
[5] AZ Delta, Dept Prevent, Roeselare, Belgium
关键词
coronary artery disease; pelvic shield; radiation protection;
D O I
10.1002/ccd.31329
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: As cardiac catheterization operators are exposed to radiation exposure throughout their careers, optimal radiation protection is crucial. Our study was designed to assess the effects of supplementary protective measures beyond standard radiation protection attire and barriers, measuring their influence on scatter radiation exposure levels for both the operator and the patient. Aims: The objective of this trial is to assess the impact of a lead shield on scatter radiation exposure for both the operator and the patient. Methods: We conducted a prospective, randomized clinical trial in which procedures were allocated to incorporate the use of a reusable lead apron designed to shield the lower body of the patient. Both operators and patients were outfitted with real-time procedure-specific dosimeters to monitor exposure. All patients undergoing radial access procedures were entered into a randomization process. The study's dual primary outcomes included the relative operator dose above (RODt) and under (RODu) the protective gear, as well as the scatter patient radiation dose (RPD), which was calculated as the measured radiation exposure (mu Sv) standardized against the dose area product (DAP). Results: Out of 400 procedures that were randomized, data from 346 procedures was complete for analysis. The use of the pelvic shield resulted in a substantial decrease in the RODt and RODu, with reductions of 25% and 40%, respectively (p < 0.0001). There was also a 38% reduction observed in the scatter RPD. In patients with a high BMI, the effectiveness of the pelvic shield varied. Conclusion: Employing an auxiliary pelvic shield significantly diminishes scatter radiation exposure for both the operator and the patient.
引用
收藏
页码:475 / 482
页数:8
相关论文
共 8 条
[1]   Occupational Health Risks in Cardiac Catheterization Laboratory Workers [J].
Andreassi, Maria Grazia ;
Piccaluga, Emanuela ;
Guagliumi, Giulio ;
Del Greco, Maurizio ;
Gaita, Fiorenzo ;
Picano, Eugenio .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (04)
[2]  
Davidsen C., 2023, CIRC-CARDIOVASC INTE, V16, P745
[3]   A quality project for radiation reduction in the cath lab [J].
de Ceuninck, Michel ;
Muyldermans, Philip ;
van de Walle, Stefaan ;
Bergez, Bernard ;
Haspeslagh, Rik ;
Stammen, Francis ;
Dujardin, Karl .
ACTA CARDIOLOGICA, 2019, 74 (01) :38-44
[4]   Risk of cataract among interventional cardiologists and catheterization lab staff: A systematic review and meta-analysis [J].
Elmaraezy, Ahmed ;
Morra, Mostafa Ebraheem ;
Mohammed, Abdelrhman Tarek ;
Al-Habaa, Ahmed ;
Elgebaly, Ahmed ;
Ghazy, Ahmed Abdelmotaleb ;
Khalil, Adham M. ;
Nguyen Tien Huy ;
Hirayama, Kenji .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 90 (01) :1-9
[5]   Efficacy of MAVIG X-Ray Protective Drapes in Reducing CTO Operator Radiation [J].
McCutcheon, Keir ;
Vanhaverbeke, Maarten ;
Dabin, Jeremie ;
Pauwels, Ruben ;
Schoonjans, Werner ;
Desmet, Walter ;
Bennett, Johan .
JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2021, 2021
[6]   A randomized study comparing the use of a pelvic lead shield during trans-radial interventions: Threefold decrease in radiation to the operator but double exposure to the patient [J].
Musallam, Anees ;
Volis, Ina ;
Dadaev, Svetlana ;
Abergel, Eitan ;
Soni, Amit ;
Yalonetsky, Sergey ;
Kerner, Arthur ;
Roguin, Ariel .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2015, 85 (07) :1164-1170
[7]  
Picano Eugenio., 2004, British Medical Journal, V328, P578
[8]   Cancer Risks in US Radiologic Technologists Working With Fluoroscopically Guided Interventional Procedures, 1994-2008 [J].
Mautz, Alan ;
Mulligan, Margaret ;
Budovec, Joseph J. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 206 (05) :1109-1109