Safety and arch complications after hemiarch versus total arch replacement with stented elephant trunk in acute type 1 dissection: Is a stent graft always beneficial?

被引:5
作者
Hayashi, Jun [1 ]
Nakajima, Hiroyuki [1 ]
Asakura, Toshihisa [1 ]
Sho, Ri [2 ]
Tokunaga, Chiho [1 ]
Takazawa, Akitoshi [1 ]
Yoshitake, Akihiro [1 ]
机构
[1] Saitama Med Univ, Int Med Ctr, Dept Cardiovasc Surg, 1397-1 Yamane Hidaka, Saitama 3501298, Japan
[2] Yamagata Univ, Grad Sch Med Sci, Dept Publ Hlth & Hyg, Yamagata, Japan
关键词
acute aortic dissection; total arch replacement; hemiarch replacement; elephant trunk; open stent; A AORTIC DISSECTION; REPAIR; MANAGEMENT; OUTCOMES;
D O I
10.1016/j.xjon.2022.06.014
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: We aimed to determine the efficacy of total arch replacement with stented elephant trunk by comparing it with hemiarch replacement with and without open stent graft for acute aortic dissection type 1. Methods: We reviewed records of 177 patients who underwent hemiarch replacement (HAR group) (concomitant open stent, 125) and 98 patients who underwent acute type 1 dissection. Compared with the TAR group, the HAR group was older (68.1 vs 60.9 years; P < .01) and had more thrombosed false lumen (28.8% vs Results: In-hospital death occurred for 7 patients in the HAR group and 1 patient in the TAR group (P = .17). More patients in the TAR group had a postoperative thrombosed false lumen, compared with the HAR group (68% vs 54%, P = .03). In patients with preoperative nonthrombosed false lumen in the HAR group, the rate of postoperative thrombosis was significantly lower than with versus without an open stent (31% vs 65%, P = .01). The rate of freedom from an aortic arch event in the TAR group at 5 years was significantly greater than that in the HAR group Conclusions: Stented elephant trunk with TAR provided a high rate of false lumen thrombosis and a low incidence of arch events, whereas an open stent during HAR was not beneficial in terms of false lumen thrombosis and arch event prevention.
引用
收藏
页码:14 / 22
页数:9
相关论文
共 14 条
[1]   Proximal fixation of thoracic stent-grafts as a function of oversizing and increasing aortic arch angulation in human cadaveric aortas [J].
Canaud, Ludovic ;
Alric, Pierre ;
Laurent, Martrille ;
Baum, Thierry-Pascal ;
Branchereau, Pascal ;
Marty-Ane, Charles Henri ;
Berthet, Jean-Phillipe .
JOURNAL OF ENDOVASCULAR THERAPY, 2008, 15 (03) :326-334
[2]   Factors favoring stent-graft collapse after thoracic endovascular aortic repair [J].
Canaud, Ludovic ;
Alric, Pierre ;
Desgranges, Pascal ;
Marzelle, Jean ;
Marty-Ane, Charles ;
Becquemin, Jean-Pierre .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 139 (05) :1153-1157
[3]   Total Arch Replacement Versus More Conservative Management in Type A Acute Aortic Dissection [J].
Di Eusanio, Marco ;
Berretta, Paolo ;
Cefarelli, Mariano ;
Jacopo, Alfonsi ;
Murana, Giacomo ;
Castrovinci, Sebastiano ;
Di Bartolomeo, Roberto .
ANNALS OF THORACIC SURGERY, 2015, 100 (01) :88-94
[4]  
Kim JB, 2011, EUR J CARDIO-THORAC, V40, P881, DOI 10.1016/j.ejcts.2010.12.035
[5]   Early and late outcomes of repaired acute DeBakey type I aortic dissection after graft replacement [J].
Omura, Atsushi ;
Miyahara, Shunsuke ;
Yamanaka, Katsuhiro ;
Sakamoto, Toshihito ;
Matsumori, Masamichi ;
Okada, Kenji ;
Okita, Yutaka .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2016, 151 (02) :341-348
[6]   Antegrade Thoracic Stent Grafting During Repair of Acute DeBakey I Dissection Prevents Development of Thoracoabdominal Aortic Aneurysms [J].
Pochettino, Alberto ;
Brinkman, William T. ;
Moeller, Patrick ;
Szeto, Wilson Y. ;
Moser, William ;
Cornelius, Katherine ;
Bowen, Frank W. ;
Woo, Y. Joseph ;
Bavaria, Joseph E. .
ANNALS OF THORACIC SURGERY, 2009, 88 (02) :482-490
[7]   Is Total Arch Replacement Associated With Worse Outcomes During Repair of Acute Type A Aortic Dissection? [J].
Rice, Robert D. ;
Sandhu, Harleen K. ;
Leake, Samuel S. ;
Afifi, Rana O. ;
Azizzadeh, Ali ;
Charlton-Ouw, Kristofer M. ;
Nguyen, Tom C. ;
Miller, Charles C., III ;
Safi, Hazim J. ;
Estrera, Anthony L. .
ANNALS OF THORACIC SURGERY, 2015, 100 (06) :2159-2166
[8]   Evolution of Simplified Frozen Elephant Trunk Repair for Acute DeBakey Type I Dissection: Midterm Outcomes [J].
Roselli, Eric E. ;
Idrees, Jay J. ;
Bakaeen, Faisal G. ;
Tong, Michael Z. ;
Soltesz, Edward G. ;
Mick, Stephanie ;
Johnston, Douglas R. ;
Eagleton, Mathew J. ;
Menon, Venu ;
Svensson, Lars G. ;
Reece, T. Brett .
ANNALS OF THORACIC SURGERY, 2018, 105 (03) :749-756
[9]   Acute type A aortic dissection extending beyond ascending aorta: Limited or extensive distal repair [J].
Rylski, Bartosz ;
Beyersdorf, Friedhelm ;
Kari, Fabian A. ;
Schlosser, Julia ;
Blanke, Philipp ;
Siepe, Matthias .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 148 (03) :949-954
[10]   Early and midterm outcomes of hemiarch replacement combined with stented elephant trunk in the management of acute DeBakey type I aortic dissection: Comparison with total arch replacement [J].
Shi, Enyi ;
Gu, Tianxiang ;
Yu, Yang ;
Yu, Lei ;
Wang, Chun ;
Fang, Qin ;
Zhang, Yuhai .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 148 (05) :2125-2131