Synthetic CT generation using Zero TE MR for head-and-neck radiotherapy

被引:0
作者
Lauwers, Iris [1 ]
Capala, Marta [1 ]
Kaushik, Sandeep [2 ,3 ]
Rusko, Laszlo [4 ]
Cozzini, Cristina [2 ]
Kleijnen, Jean-Paul [5 ]
Wyatt, Jonathan [6 ,7 ]
McCallum, Hazel [6 ,7 ]
Verduijn, Gerda [1 ]
Wiesinger, Florian [2 ]
Hernandez-Tamames, Juan [8 ,9 ]
Petit, Steven [1 ]
机构
[1] Univ Med Ctr Rotterdam, Erasmus MC Canc Inst, Dept Radiotherapy, Rotterdam, Netherlands
[2] GE Healthcare, Munich, Germany
[3] Univ Zurich, Dept Quant Biomed, Zurich, Switzerland
[4] GE Healthcare Magyarorszag Kft, Budapest, Hungary
[5] Haaglanden MC, Dept Med Phys, The Hague, Netherlands
[6] Newcastle Univ, Translat & Clin Res Inst, Newcastle, England
[7] Newcastle Upon Tyne Hosp NHS Fdn Trust, Northern Ctr Canc Care, Newcastle, England
[8] Erasmus MC, Dept Radiol & Nucl Med, Rotterdam, Netherlands
[9] Delft Univ Technol, Dept Imaging Phys, Delft, Netherlands
关键词
MROnly; Zero TE MRI; ZTE; Synthetic CT; Head and neck;
D O I
10.1016/j.radonc.2025.110762
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and Purpose: MRI-based synthetic CTs (synCTs) show promise to replace planning CT scans in various anatomical regions. However, the head-and-neck region remains challenging because of patient-specific air, bone and soft tissues interfaces and oropharynx cavities. Zero-Echo-Time (ZTE) MRI can be fast and silent, accurately discriminate bone and air, and could potentially lead to high dose calculation accuracy, but is relatively unexplored for the head-and-neck region. Here, we prospectively evaluated the dosimetric accuracy of a novel, fast ZTE sequence for synCT generation. Materials and Methods: The method was developed based on 127 patients and validated in an independent test (n = 17). synCTs were generated using a multi-task 2D U-net from ZTE MRIs (scanning time: 2:33 min (normal scan) or 56 s (accelerated scan)). Clinical treatment plans were recalculated on the synCT. The Hounsfield Units (HU) and dose-volume-histogram metrics were compared between the synCT and CT. Subsequently, synthetic treatment plans were generated to systematically assess dosimetry accuracy in different anatomical regions using dose-volume-histogram metrics. Results: The mean absolute error between the synCT and CT was 94 +/- 11 HU inside the patient contour. For the clinical plans, 98.8% of PTV metrics deviated less than 2% between synCT and CT and all OAR metrics deviated less than 1 Gy. The synthetic plans showed larger dose differences depending on the location of the PTV. Conclusions: Excellent dose agreement was found based on clinical plans between the CT and a ZTE-MR-based synCT in the head-and-neck region. Synthetic plans are an important addition to clinical plans to evaluate the dosimetric accuracy of synCT scans.
引用
收藏
页数:7
相关论文
共 28 条
  • [1] Deep Learning for Synthetic CT from Bone MRI in the Head and Neck
    Bambach, S.
    Ho, M. -L
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2022, 43 (08) : 1172 - 1179
  • [2] Deep learning MRI-only synthetic-CT generation for pelvis, brain and head and neck cancers
    Bird, David
    Speight, Richard
    Andersson, Sebastian
    Wingqvist, Jenny
    Al-Qaisieh, Bashar
    [J]. RADIOTHERAPY AND ONCOLOGY, 2024, 191
  • [3] Deep learning methods to generate synthetic CT from MRI in radiotherapy: A literature review
    Boulanger, M.
    Nunes, Jean-Claude
    Chourak, H.
    Largent, A.
    Tahri, S.
    Acosta, O.
    De Crevoisier, R.
    Lafond, C.
    Barateau, A.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 89 : 265 - 281
  • [4] Ccmo, 2019, Deep learning based MR Only Radiotherapy for head-and-neck cancer
  • [5] Dosimetric evaluation of synthetic CT for head and neck radiotherapy generated by a patch-based three-dimensional convolutional neural network
    Dinkla, Anna M.
    Florkow, Mateusz C.
    Maspero, Matteo
    Savenije, Mark H. F.
    Zijlstra, Frank
    Doornaert, Patricia A. H.
    van Stralen, Marijn
    Philippens, Marielle E. P.
    van den Berg, Cornelis A. T.
    Seevinck, Peter R.
    [J]. MEDICAL PHYSICS, 2019, 46 (09) : 4095 - 4104
  • [6] Qualitative and quantitative ultrashort echo time (UTE) imaging of cortical bone
    Du, Jiang
    Carl, Michael
    Bydder, Mark
    Takahashi, Atsushi
    Chung, Christine B.
    Bydder, Graeme M.
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2010, 207 (02) : 304 - 311
  • [7] In-phase zero TE musculoskeletal imaging
    Engstrom, Mathias
    McKinnon, Graeme
    Cozzini, Cristina
    Wiesinger, Florian
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (01) : 195 - 202
  • [8] Systematic Review of Synthetic Computed Tomography Generation Methodologies for Use in Magnetic Resonance Imaging-Only Radiation Therapy
    Johnstone, Emily
    Wyatt, Jonathan J.
    Henry, Ann M.
    Short, Susan C.
    Sebag-Montefiore, David
    Murray, Louise
    Kelly, Charles G.
    McCallum, Hazel M.
    Speight, Richard
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 100 (01): : 199 - 217
  • [9] DEDICATED MAGNETIC RESONANCE IMAGING IN THE RADIOTHERAPY CLINIC
    Karlsson, Mikael
    Karlsson, Magnus G.
    Nyholm, Tufve
    Amies, Christopher
    Zackrisson, Bjorn
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (02): : 644 - 651
  • [10] Region of interest focused MRI to synthetic CT translation using regression and segmentation multi-task network
    Kaushik, Sandeep S.
    Bylund, Mikael
    Cozzini, Cristina
    Shanbhag, Dattesh
    Petit, Steven F.
    Wyatt, Jonathan J.
    Menzel, Marion, I
    Pirkl, Carolin
    Mehta, Bhairav
    Chauhan, Vikas
    Chandrasekharan, Kesavadas
    Jonsson, Joakim
    Nyholm, Tufve
    Wiesinger, Florian
    Menze, Bjoern
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (19)