Minimum Sampling Duration for Continuous Glucose Monitoring Metrics to Achieve Representative Glycemic Outcomes in Suboptimal Continuous Glucose Monitor Use

被引:5
作者
Akturk, Halis K. [1 ]
Sakamoto, Casey [1 ]
Vigers, Tim [1 ]
Shah, Viral N. [1 ]
Pyle, Laura [1 ]
机构
[1] Univ Colorado, Barbara Davis Ctr Diabet, Aurora, CO USA
关键词
type; 1; diabetes; continuous glucose monitoring; time in range; optimal sampling; INTERNATIONAL CONSENSUS; ADULTS;
D O I
10.1177/19322968231200901
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Two weeks of continuous glucose monitoring (CGM) sampling with >70% CGM use is recommended to accurately reflect 90 days of glycemic metrics. However, minimum sampling duration for CGM use <70% is not well studied. We investigated the minimum duration of CGM sampling required for each CGM metric to achieve representative glycemic outcomes for <70% CGM use over 90 days. Methods: Ninety days of CGM data were collected in 336 real-life CGM users with type 1 diabetes. CGM data were grouped in 5% increments of CGM use (45%-95%) over 90 days. For each CGM metric and each CGM use category, the correlation between the summary statistic calculated using each sampling period and all 90 days of data was determined using the squared value of the Spearmen correlation coefficient (R-2). Results: For CGM use 45% to 95% over 90 days, minimum sampling period is 14 days for mean glucose, time in range (70-180 mg/dL), time >180 mg/dL, and time >250 mg/dL; 28 days for coefficient of variation, and 35 days for time <54 mg/dL. For time <70 mg/dL, 28 days is sufficient between 45 and 80% CGM use, while 21 days is required >80% CGM use. Conclusion: We defined minimum sampling durations for all CGM metrics in suboptimal CGM use. CGM sampling of at least 14 days is required for >45% CGM use over 90 days to sufficiently reflect most of the CGM metrics. Assessment of hypoglycemia and coefficient of variation require a longer sampling period regardless of CGM use duration.
引用
收藏
页码:345 / 351
页数:7
相关论文
共 50 条
[31]   Optimal Data Collection Period for Continuous Glucose Monitoring to Assess Long-Term Glycemic Control: Revisited [J].
Cichosz, Simon Lebech ;
Jensen, Morten Hasselstrom ;
Hejlesen, Ole .
JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2023, 17 (03) :690-695
[32]   Assessing Patterns of Continuous Glucose Monitoring Use and Metrics of Glycemic Control in Type 1 Diabetes and Type 2 Diabetes Patients in the Veterans Health Care System: Integrating Continuous Glucose Monitoring Device Data with Electronic Health Records Data [J].
Okuno, Tomoki ;
Macwan, Sharon A. ;
Miller, Donald ;
Norman, Gregory J. ;
Reaven, Peter ;
Zhou, Jin J. .
DIABETES TECHNOLOGY & THERAPEUTICS, 2024, 26 (11) :806-813
[33]   Association between continuous glucose monitoring metrics and clinical outcomes in adults with type 1 diabetes in a real-world setting [J].
Mcqueen, Robert Brett ;
Perez-Nieves, Magaly ;
Alonso, G. Todd ;
Fan, Ludi ;
Hankosky, Emily R. ;
Shah, Viral N. ;
Yan, Yuer ;
Ellis, Samuel L. ;
Juneja, Rattan .
DIABETES RESEARCH AND CLINICAL PRACTICE, 2024, 212
[34]   Expert Recommendations for Using Time-in-Range and Other Continuous Glucose Monitoring Metrics to Achieve Patient-Centered Glycemic Control in People With Diabetes [J].
Bellido, Virginia ;
Aguilera, Eva ;
Cardona-Hernandez, Roque ;
Diaz-Soto, Gonzalo ;
Perez de Villar, Noemi Gonzalez ;
Picon-Cesar, Maria J. ;
Ampudia-Blasco, Francisco Javier .
JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2023, 17 (05) :1326-1336
[35]   Use of Continuous Glucose Monitoring to Facilitate Perioperative Glycemic Management: A Case Report [J].
DiGiusto, Matthew ;
Wolf, Risa M. ;
Arcara, Kristin M. ;
Vanderhoek, Samuel M. .
A & A PRACTICE, 2021, 15 (03) :e01438
[36]   Use of continuous glucose monitoring to improve glycemic management: A clinician's guide [J].
Schumacher, Christie A. ;
Isaacs, Diana ;
Collier, Izabela ;
Klinkebiel, Drew .
JOURNAL OF THE AMERICAN COLLEGE OF CLINICAL PHARMACY, 2020, 3 (07) :1333-1343
[37]   Use of Retrospective Continuous Glucose Monitoring Data Is Underrated and Underused [J].
Nguyen, Quang ;
Iyyavoo, Anish Arul ;
Parkin, Christopher G. .
JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2023, 17 (03) :843-849
[39]   Continuous glucose monitor metrics from five studies identify participants at risk for type 1 diabetes development [J].
Calhoun, Peter ;
Spanbauer, Charles ;
Steck, Andrea K. ;
Frohnert, Brigitte I. ;
Herman, Mark A. ;
Keymeulen, Bart ;
Veijola, Riitta ;
Toppari, Jorma ;
Desouter, Aster ;
Gorus, Frans ;
Atkinson, Mark ;
Wilson, Darrell M. ;
Pietropaolo, Susan ;
Beck, Roy W. .
DIABETOLOGIA, 2025, 68 (05) :930-939
[40]   Alarm Settings of Continuous Glucose Monitoring Systems and Associations to Glucose Outcomes in Type 1 Diabetes [J].
Lin, Yu Kuei ;
Groat, Danielle ;
Chan, Owen ;
Hung, Man ;
Sharma, Anu ;
Varner, Michael W. ;
Gouripeddi, Ramkiran ;
Facelli, Julio C. ;
Fisher, Simon J. .
JOURNAL OF THE ENDOCRINE SOCIETY, 2020, 4 (01)