Thermodynamic performance and CO2 emission analysis of transcritical CO2 two-stage compression refrigeration system with intermediate gas supplementation

被引:0
作者
Wang, Youdong [1 ,2 ]
Li, Xiaoqiong [2 ]
Guo, Yanhua [3 ]
Dai, Jian [4 ]
Song, Jitian [1 ]
He, Qing [2 ]
Zhang, Zhentao [2 ]
Xu, Qing [1 ]
Yang, Junling [2 ]
机构
[1] Tianjin Univ Sci & Technol, Coll Mech Engn, Tianjin Key Lab Integrated Design & Online Monitor, Tianjin 300222, Peoples R China
[2] Chinese Acad Sci, Tech Inst Phys & Chem, Beijing 100190, Peoples R China
[3] Huazhong Univ Sci & Technol, Sch Energy & Power Engn, Wuhan 430074, Peoples R China
[4] Nanchang Univ, Sch Civil Engn & Architecture, Nanchang 330031, Peoples R China
关键词
Two-stage compression; Refrigeration system; Intermediate gas supplementation; CO2; emission; Economic cost; HEAT-PUMP SYSTEM; THEORETICAL-ANALYSIS; CYCLE; SIMULATION; ENERGY;
D O I
10.1016/j.energy.2025.135193
中图分类号
O414.1 [热力学];
学科分类号
摘要
Low evaporation temperature characteristic of transcritical CO2 refrigeration systems results in high discharge temperature and decreased system efficiency. In this paper, a transcritical CO2 two-stage compression refrigeration system with intermediate gas supplementation (TCTCRS-IGS) was proposed, and thermodynamic and CO2 emission analysis was conducted. Firstly, the transcritical CO2 two-stage compression refrigeration system (TCTCRS) with and without intermediate gas supplementation was compared. Then, experimental investigations were conducted to analyze the effects of evaporation temperature, high pressure, intermediate pressure, gas cooler outlet temperature, and intermediate cooler outlet temperature. Besides, CO2 emission was analyzed at different conditions. The results show that the TCTCRS-IGS system achieved a 24.73 % reduction in discharge temperature and a 7.42 % increase in COP compared to TCTCRS. Meanwhile, the TCTCRS-IGS system is less affected by the intermediate cooler outlet temperature. However, it is significantly influenced by the other parameters. As the evaporation temperature rises, the cooling capacity and COP improve by 57.7 % and 23.9 %, respectively. The COP shows an initial increase followed by a decrease with high pressure, reaching a maximum value of 1.39. The COP reaches its highest point of 1.5 at an intermediate pressure of 4.2 MPa. As the gas cooler outlet temperature increases, COP initially decrease and then rise. Besides, the CO2 emissions are influenced by evaporation temperature, high pressure, and gas cooler outlet temperature, with little impact from intermediate pressure and cooler outlet temperature. The TCTCRS-IGS system offers economic costs through superior energy efficiency, lowering operating and environmental costs. The TCTCRS-IGS system contributes to the enhancement of the TCTCRS performance, fostering the development of low-carbon technology.
引用
收藏
页数:14
相关论文
共 49 条
  • [11] Improvement and experimental research of CO2 two-rolling piston expander
    Hu, Jing
    Li, Minxia
    Zhao, Li
    Xia, Borui
    Ma, Yitai
    [J]. ENERGY, 2015, 93 : 2199 - 2207
  • [12] Thermodynamic analysis and economic assessment of a carbon dioxide hydrate-based vapor compression refrigeration system using load shifting controls in summer
    Hua, Nan
    Lu, Tiejun
    Yang, Liwei
    Mckeown, Andrew
    Yu, Zhibin
    Xu, Bing
    Sciacovelli, Adriano
    Ding, Yulong
    Li, Yongliang
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2022, 251
  • [13] Performance analysis of two-stage CO2 transcritical refrigeration cycles with absorption subcooling and mechanical recooling
    Huang, Caoxuheng
    Li, Zeyu
    Ye, Zhihao
    Wang, Ruiting
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 153 : 33 - 47
  • [14] Thermodynamic study of carbon dioxide transcritical refrigeration cycle with dedicated subcooling and cascade recooling
    Huang, Caoxuheng
    Li, Zeyu
    Ye, Zhihao
    Wang, Ruiting
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 137 : 80 - 90
  • [15] Assessment of total equivalent warming impact (TEWI) of supermarket refrigeration systems
    Islam, Md. Amirul
    Srinivasan, K.
    Thu, Kyaw
    Saha, Bidyut Baran
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2017, 42 (43) : 26973 - 26983
  • [16] MULTI-OBJECTIVE OPTIMIZATION OF A R744/R134A CASCADE REFRIGERATION SYSTEM: EXERGETIC, ECONOMIC, ENVIRONMENTAL, AND SENSITIVE ANALYSIS (3ES)
    Keshtkar, M. M.
    Talebizadeh, P.
    [J]. JOURNAL OF THERMAL ENGINEERING, 2019, 5 (04): : 237 - 250
  • [17] Kline S.J., 1963, Mech. Eng., V75, P3, DOI DOI 10.1111/JCMM.13453
  • [18] Optimal compressor discharge pressure and performance characteristics of transcritical CO2 heat pump for crude oil heating
    Li, Conghui
    Jiang, Peixue
    Zhu, Yinhai
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 144 : 99 - 107
  • [19] A comprehensive investigation on the design and off-design performance of supercritical carbon dioxide power system based on the small-scale lead-cooled fast reactor
    Li, Hang
    Fan, Gang
    Cao, Liyan
    Yang, Yi
    Yan, Xiao
    Dai, Yiping
    Zhang, Guojie
    Wang, Junlei
    [J]. JOURNAL OF CLEANER PRODUCTION, 2020, 256
  • [20] Thermodynamic analysis of a modified two-stage transcritical CO2 refrigeration cycle with an ejector and a subcooler
    Li, Huanmin
    Huang, Qiuyue
    Yu, Jianlin
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2024, 168 : 492 - 505