Thermodynamic performance and CO2 emission analysis of transcritical CO2 two-stage compression refrigeration system with intermediate gas supplementation

被引:0
作者
Wang, Youdong [1 ,2 ]
Li, Xiaoqiong [2 ]
Guo, Yanhua [3 ]
Dai, Jian [4 ]
Song, Jitian [1 ]
He, Qing [2 ]
Zhang, Zhentao [2 ]
Xu, Qing [1 ]
Yang, Junling [2 ]
机构
[1] Tianjin Univ Sci & Technol, Coll Mech Engn, Tianjin Key Lab Integrated Design & Online Monitor, Tianjin 300222, Peoples R China
[2] Chinese Acad Sci, Tech Inst Phys & Chem, Beijing 100190, Peoples R China
[3] Huazhong Univ Sci & Technol, Sch Energy & Power Engn, Wuhan 430074, Peoples R China
[4] Nanchang Univ, Sch Civil Engn & Architecture, Nanchang 330031, Peoples R China
关键词
Two-stage compression; Refrigeration system; Intermediate gas supplementation; CO2; emission; Economic cost; HEAT-PUMP SYSTEM; THEORETICAL-ANALYSIS; CYCLE; SIMULATION; ENERGY;
D O I
10.1016/j.energy.2025.135193
中图分类号
O414.1 [热力学];
学科分类号
摘要
Low evaporation temperature characteristic of transcritical CO2 refrigeration systems results in high discharge temperature and decreased system efficiency. In this paper, a transcritical CO2 two-stage compression refrigeration system with intermediate gas supplementation (TCTCRS-IGS) was proposed, and thermodynamic and CO2 emission analysis was conducted. Firstly, the transcritical CO2 two-stage compression refrigeration system (TCTCRS) with and without intermediate gas supplementation was compared. Then, experimental investigations were conducted to analyze the effects of evaporation temperature, high pressure, intermediate pressure, gas cooler outlet temperature, and intermediate cooler outlet temperature. Besides, CO2 emission was analyzed at different conditions. The results show that the TCTCRS-IGS system achieved a 24.73 % reduction in discharge temperature and a 7.42 % increase in COP compared to TCTCRS. Meanwhile, the TCTCRS-IGS system is less affected by the intermediate cooler outlet temperature. However, it is significantly influenced by the other parameters. As the evaporation temperature rises, the cooling capacity and COP improve by 57.7 % and 23.9 %, respectively. The COP shows an initial increase followed by a decrease with high pressure, reaching a maximum value of 1.39. The COP reaches its highest point of 1.5 at an intermediate pressure of 4.2 MPa. As the gas cooler outlet temperature increases, COP initially decrease and then rise. Besides, the CO2 emissions are influenced by evaporation temperature, high pressure, and gas cooler outlet temperature, with little impact from intermediate pressure and cooler outlet temperature. The TCTCRS-IGS system offers economic costs through superior energy efficiency, lowering operating and environmental costs. The TCTCRS-IGS system contributes to the enhancement of the TCTCRS performance, fostering the development of low-carbon technology.
引用
收藏
页数:14
相关论文
共 49 条
  • [1] Comparative thermodynamic performance analysis of a cascade refrigeration system with new refrigerants paired with CO2
    Adebayo, Victor
    Abid, Muhammad
    Adedeji, Michael
    Dagbasi, Mustafa
    Bamisile, Olusola
    [J]. APPLIED THERMAL ENGINEERING, 2021, 184
  • [2] [Anonymous], 2023, U.N, the UAE consensus brochure, U.N, the UAE
  • [3] Improvements in the cooling capacity and the COP of a transcritical CO2 refrigeration plant operating with a thermoelectric subcooling system
    Astrain, D.
    Merino, A.
    Catalan, L.
    Aranguren, P.
    Araiz, M.
    Sanchez, D.
    Cabello, R.
    Llopis, R.
    [J]. APPLIED THERMAL ENGINEERING, 2019, 155 : 110 - 122
  • [4] A comparative study of CO2 refrigeration systems
    Bellos, Evangelos
    Tzivanidis, Christos
    [J]. ENERGY CONVERSION AND MANAGEMENT-X, 2019, 1
  • [5] Preliminary study on the feasibility assessment of CO2 booster refrigeration systems for supermarket application in China: An energetic, economic, and environmental analysis
    Cui, Qi
    Gao, Enyuan
    Zhang, Zhiyuan
    Zhang, Xiaosong
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2020, 225 (225)
  • [6] Exergy, carbon footprint and cost lifecycle evaluation of cascade mechanical subcooling CO2 commercial refrigeration system in China
    Dai, Baomin
    Cao, Yu
    Zhou, Xuan
    Liu, Shengchun
    Fu, Rao
    Li, Cenxi
    Wang, Dabiao
    [J]. JOURNAL OF CLEANER PRODUCTION, 2024, 434
  • [7] Energy and environmental performance assessment of R744 booster supermarket refrigeration systems operating in warm climates
    Gullo, Paride
    Elmegaard, Brian
    Cortella, Giovanni
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 64 : 61 - 79
  • [8] Thermodynamic analysis of an enhanced ejector vapor injection refrigeration cycle for CO2 transcritical operation at low evaporating temperatures
    Gutierrez, Miguel Avila
    Perez, Bernardo Peris
    Munoz, Fernando Dominguez
    Besagni, Giorgio
    Lissen, Jose Manuel Salmeron
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2024, 165 : 257 - 276
  • [9] Applicability evaluation of internal heat exchanger in CO2 transcritical cycle considering compressor operation boundaries
    He, Yu-Jia
    Tai, Ying-Di
    Fakrouche, Nassim
    Zhang, Chun-Lu
    [J]. APPLIED ENERGY, 2023, 349
  • [10] Evaporation of refrigerant R134a, R404A and R407C with low mass flux in smooth vertical tube
    Horak, P.
    Formanek, M.
    Fecer, T.
    Plasek, J.
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2021, 181 (181)