A novel multimodality anthropomorphic phantom enhances compliance with quality assurance guidelines for magnetic resonance imaging in radiotherapy

被引:0
|
作者
Alzahrani, Meshal [1 ,2 ,3 ]
Broadbent, David A. [2 ,3 ]
Teh, Irvin [3 ]
Al-Qaisieh, Bashar [2 ]
Johnstone, Emily [4 ]
Speight, Richard [2 ]
机构
[1] King Abdulaziz Univ, Fac Appl Med Sci, Dept Radiol Sci, Jeddah, Saudi Arabia
[2] Leeds Teaching Hosp NHS Trust, Dept Med Phys & Engn, Leeds, England
[3] Univ Leeds, Leeds Inst Cardiovasc & Metab Med, Leeds, England
[4] Christie NHS Fdn Trust, Christie Med Phys & Engn, Manchester, England
来源
PHYSICS & IMAGING IN RADIATION ONCOLOGY | 2025年 / 33卷
关键词
Magnetic resonance imaging; Radiotherapy; MRI in RT; Quality assurance; ACR phantom; Multimodal anthropomorphic phantom; IMPLEMENTATION; SIMULATION;
D O I
10.1016/j.phro.2025.100707
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: The use of magnetic resonance imaging (MRI) for radiotherapy (RT) simulation has grown, prompting quality assurance (QA) guidelines by the Institute of Physics and Engineering in Medicine (IPEM) and the American Association of Physicists in Medicine (AAPM). This study compares a novel multimodality anthropomorphic phantom to an American College of Radiology (ACR) phantom for a subset of these MRI-specific QA tests in RT. Materials and methods: A novel 3D-printed multimodality head-and-neck anthropomorphic phantom was compared to an ACR large MRI phantom. IPEM and AAPM-recommended QA tests were conducted, including informatics/connectivity/data transfer, MRI-CT registration, end-to-end QA, and signal-to-noise ratio (SNR)/ percentage integral uniformity (PIU) assessments using RT accessories. Results: Both phantoms were suitable for informatics/connectivity/data transfer. In MRI-CT registration, no errors were found; the ACR phantom offered more quantitative landmarks, while the anthropomorphic phantom provided limited structures. Both phantoms achieved target registration errors (TREs) below 0.97 mm and dice similarity coefficient (DSC) values above 0.9, meeting guidelines. For end-to-end QA, the anthropomorphic phantom facilitated dose measurements of 1.994 Gy versus a calculated 2.01 Gy (-0.8 %). SNR and PIU assessments showed higher values in radiology setups compared to RT setups for both phantoms. Conclusions: Multimodality anthropomorphic phantoms compatible with dosimetric equipment allow realistic end-to-end QA, unlike the ACR phantom. While the ACR phantom is suitable for informatics and MRI-CT registration, anthropomorphic phantoms better represent clinical scenarios. For comprehensive QA, both ACR and anthropomorphic phantoms are required. Additionally, large field-of-view (FOV) phantoms are crucial for evaluating large FOV MRI distortions.
引用
收藏
页数:7
相关论文
共 41 条
  • [31] Quality assurance assessment of intra-acquisition diffusion-weighted and T2-weighted magnetic resonance imaging registration and contour propagation for head and neck cancer radiotherapy
    Naser, Mohamed A. A.
    Wahid, Kareem A. A.
    Ahmed, Sara
    Salama, Vivian
    Dede, Cem
    Edwards, Benjamin W. W.
    Lin, Ruitao
    McDonald, Brigid
    Salzillo, Travis C. C.
    He, Renjie
    Ding, Yao
    Abdelaal, Moamen Abobakr
    Thill, Daniel
    O'Connell, Nicolette
    Willcut, Virgil
    Christodouleas, John P. P.
    Lai, Stephen Y. Y.
    Fuller, Clifton D. D.
    Mohamed, Abdallah S. R.
    MEDICAL PHYSICS, 2023, 50 (04) : 2089 - 2099
  • [32] An evaluation of quality assurance guidelines comparing the American College of Radiology and American Association of Physicists in Medicine task group 284 for magnetic resonance simulation
    Buatti, Jacob S.
    Gallagher, Kyle J.
    Bailey, Isaac
    Griglock, Thomas
    Heard, Malcolm
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (08):
  • [33] MAGNETIC-RESONANCE-IMAGING OF FRICKE-DOPED AGAROSE GELS FOR THE VISUALIZATION OF RADIOTHERAPY DOSE DISTRIBUTIONS IN A LUNG PHANTOM
    THOMAS, SJ
    WILKINSON, ID
    DIXON, AK
    DENDY, PP
    BRITISH JOURNAL OF RADIOLOGY, 1992, 65 (770): : 167 - 169
  • [34] Patient-specific quality assurance strategies for synthetic computed tomography in magnetic resonance-only radiotherapy of the abdomen
    Dal Bello, Riccardo
    Lapaeva, Mariia
    La Greca Saint-Esteven, Agustina
    Wallimann, Philipp
    Gunther, Manuel
    Konukoglu, Ender
    Andratschke, Nicolaus
    Guckenberger, Matthias
    Tanadini-Lang, Stephanie
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 27
  • [35] Quality assurance issues for computed tomography-, ultrasound-, and magnetic resonance imaging-guided brachytherapy
    Cormack, Robert A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (01): : S136 - S141
  • [36] A novel phantom and method for comprehensive 3-dimensional measurement and correction of geometric distortion in magnetic resonance imaging
    Wang, DM
    Doddrell, DM
    Cowin, G
    MAGNETIC RESONANCE IMAGING, 2004, 22 (04) : 529 - 542
  • [37] A novel dynamic robotic moving phantom system for patient-specific quality assurance in real-time tumor-tracking radiotherapy
    Shiinoki, Takehiro
    Fujii, Fumitake
    Fujimoto, Koya
    Yuasa, Yuki
    Sera, Tatsuhiro
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (07): : 16 - 28
  • [38] Development of a novel task-based functional magnetic resonance imaging phantom based on a bubble-compression approach
    Yamashiro, Akihiro
    Saito, Takaaki
    Miyati, Tosiaki
    MEDICAL PHYSICS, 2022, 49 (06) : 3717 - 3728
  • [39] Cone beam computed tomography based image guidance and quality assessment of prostate cancer for magnetic resonance imaging-only radiotherapy in the pelvis
    Edmund, Jens M.
    Andreasen, Daniel
    Van Leemput, Koen
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2021, 18 : 55 - 60
  • [40] Longitudinal assessment of quality assurance measurements in a 1.5 T MR-linac: Part II-Magnetic resonance imaging
    Subashi, Ergys
    Dresner, Alex
    Tyagi, Neelam
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (06):